• Title/Summary/Keyword: Energy calibration

Search Result 430, Processing Time 0.029 seconds

The Calibration of $^{90}$ Sr Ophthalmic Applicator by Measuring Electron Current (전류 측정 방식에 의한 안과용 $^{90}$ Sr 선원의 교정)

  • 이병용;신동오;김현자;홍성언;최은경;장혜숙
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.149-154
    • /
    • 1991
  • We have designed and applied the calibrationmethod of $\^$90/Sr Ophthalmic Applicaton by measuring the electron currents. We considered the number of electrons which is emitted from the source, the area of the source, and the electron stopping power in the water, and those data were used for calculation. Film was used for evaluating the accurate source area. Average electron stopping power was obtained by analyzing ${\beta}$-ray energy spectrum. We compared between the result from our method and that from the TLD measurements. The calibration result from our method shows 63.3 ${\pm}$5.1 cGy/sec, while 50.7${\pm}$7.3 cGy/sec from TLD measurement. But the supplier's specification tells 46.89.4cGy/sec.

  • PDF

Uranium Enrichment Determination Using a New Analysis Code for the U XKα Region: HyperGam-U

  • Kim, Junhyuck;Choi, Hee-Dong;Park, Jongho
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.778-784
    • /
    • 2016
  • HyperGam-U was recently developed to determine uranium enrichment based on ${\gamma}$- and X-ray spectroscopy analysis. The $XK_{\alpha}$ region of the uranium spectrum contains 13 peaks for $^{235}U$ and $^{238}U$ and is used mainly for analysis. To describe the X-ray peaks, a Lorentzian broadened shape function was used, and methods were developed to reduce the number of fitting parameters for decomposing the strongly overlapping peaks using channel-energy, energy-width, and energy-efficiency calibration functions. For validation, eight certified reference material uranium samples covering uranium enrichments from 1% to 99% were measured using a high-resolution planar high-purity germanium detector and analyzed using the HyperGam-U code. When corrections for the attenuation and true coincidence summing were performed for the detection geometry in this experiment, the goodness of fit was improved by a few percent. The enrichment bias in this study did not exceed 2% compared with the certified values for all measured samples.

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

Comparison of the standards for absorbed dose to water of the IAEA and the KRISS, Korea in accelerator photon beams

  • L. Czap;I.J. Kim;J.I. Park;C.-Y. Yi;Y. Kim;Z. Msimang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2698-2703
    • /
    • 2024
  • A bilateral comparison was conducted between the International Atomic Energy Agency (IAEA) and the Korea Research Institute of Standards and Science (KRISS) to measure the absorbed dose to water in accelerator photon beams. KRISS served as a linking laboratory to compare the IAEA standard with the key comparison reference value (KCRV) of the BIPM.RI(I)-K6 program, in which KRISS participated in 2017. Two ionization chambers from the IAEA were used as transfer instruments for the comparison. Both laboratories measured the calibration coefficients of these instruments and calculated the ratios. The ratio of the KRISS standard to the KCRV was applied to obtain the degree of equivalence of the IAEA, along with its uncertainty. The largest deviation of the IAEA measurement from the KCRV was 3.4 mGy/Gy, significantly smaller than the expanded uncertainty of 10.7 mGy/Gy (k = 2, 95% level of confidence). This study demonstrates the equivalence of IAEA's measurement standard for accelerator photon beams to other primary standard dosimetry laboratories. It provides evidence for the satisfactory operation of IAEA's quality management system and enhances the international credibility of the IAEA SSDL network, particularly in high-energy accelerator photon beams from linear accelerators.

Determination of Horseradish Peroxidase (HRP) using an Enhanced Chemiluminescence Assay (증강 화학발광 기법을 이용한 horseradish peroxidase(HRP)의 검량)

  • Kim, Wongee;Kim, Keunhan;Lee, Seungmok
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.84-89
    • /
    • 2009
  • Our nation's water resources remain susceptible to contamination by phenolic agrichemicals. These compounds can be toxic to a variety of organisms including humans. Their disposal is restricted in many countries with strict limits for acceptable concentrations in drinking water. Enzyme-mediated in situ stabilization has been advocated as an approach for the treatment of phenolic compounds in soils and groundwater. This study reports the development of a new approach to quantify the activity of the HRP enzyme in aqueous systems. The method is based on the coupled processes of energy transfer and enhanced chemiluminescence using a luminol-$H_2O_2$-HRP system. In this study, the effects of solution pH, ionic strength and aqueous concentrations of HRP, $H_2O_2$ and enhancer were evaluated on the p-iodophenol-enhanced, HRP-catalyzed chemiluminescence reaction intensity in Tris-HCl buffer. All assay components were found to affect the maximum chemiluminescene intensity. The calibration curve for HRP showed the linear relationship with maximum light intensity.

Numerical Model for SBR Aerobic Digestion Combined with Ultrasonication and Parameter Calibration (초음파 결합형 SBR 호기성 소화의 모델과 매개변수의 보정)

  • Kim, Sunghong;Lee, Inho;Yun, Jeongwon;Lee, Dongwoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.457-468
    • /
    • 2013
  • Based on the activated sludge model(ASM), a mathematical model which represents the aerobic sludge digestion by sequencing batch reactor(SBR) combined with ultrasonic treatment was composed and performed in this study. Aerobic digestion using sequencing batch reactor(SBR) equipped with ultrasound treatment was also experimented for the purpose of parameter calibration. Most of the presented kinetic parameters in ASM or ASM2 could be used for the aerobic digestion of sludge but the parameters related in hydrolysis and decay rate needed modification. Hydrolysis rate constant of organic matter in aerobic condition was estimated at $0.3day^{-1}$ and the maximum growth rate for autotrophs in aerobic condition was $0.618day^{-1}$. Solubilization reactions of particulate organics and nitrogen by ultrasonication was added in this kinetic model. The solubilization rate is considered to be proportional to the specific energy which is defined by specific ultrasound power and sonication time. The solubilization rate constant by ultrasonication was estimated at $0.202(W/L)^{-1}day^{-1}$ in this study. Autotrophs as well as heterotrophs also decomposed by ultrasonic treatment and the nitrification reaction was limited by the lack of autotrophs accumulation in the digester.

A Study of ${{\sigma}_v}'-D_r-N$ Correlation using Large Calibration Chamber System (대형 Calibration Chamber System을 이용한 ${{\sigma}_v}'-D_r-N$ 상관관계 연구)

  • Choi, Sung-Kun;Kim, Sang-In;Lee, Chung-Ho;Kim, Dong-Hoo;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1175-1182
    • /
    • 2005
  • Using KUCCS, which enables real-time monitoring and controlling, the various boundary condition and in-situ field stress condition was simulated, to derive the correlation among ${{\sigma}_v}'-Dr-N$in domestic sandy soils. Soil specimens, having various relative density and confined stress, were formulated to evaluate N-value from the SPT. and Pile Driving Analyzer, PDA, was employed as a measuring device for the energy transfer efficiency in the rod. From the quantitative analysis of N-value, the correlating equation, $N_{60}/{D_r}^2=16.35+14.45{{\sigma}_v}'$ was obtained on the basis of Skempton's method(1986). More reliable soil parameters can be obtained from the N-value by using this study which considered regional characters and the correlation among ${{\sigma}_v}'-Dr-N$.

  • PDF

Development of Simulated HPGe Detector Spectrum for Education (교육용 모사 HPGe 검출기 스펙트럼 개발)

  • Seo, Kyung-Won;Lee, Mo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.9-13
    • /
    • 2007
  • From HPGe calibration spectrum of liquid mixed source in cylindrical vial, we developed simulated spectrum for spectrum analysis education. It is the spectrum that combine peaks separated from measured spectrum. After that, spectrum removed statistical variation of channel counts. Statistical fluctuation of the spectrum is made by Box-Muller function. The spectrum contains 18 peaks. The peak's centroid and area were defined exactly. Developed spectra are calibration spectrum, sample spectrum, background spectrum and spectra for efficiency correction for geometry and cascade coincidence.

The Evaluation of Cylindrical Gear Measurement on Teeth Roots and Bottom Profiles in Different Sections (원통기어의 다단면 치형 측정평가)

  • Moon, Sung-Min;Kang, Jae-Hwa;Kido, Hiromitsu;Kurokawa, Syuhei;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.1
    • /
    • pp.46-49
    • /
    • 2012
  • Gears are reliable and efficient power transmission elements. They have been widely used in all kinds of machinery. Nowadays, resource conservation energy conservation environmental improvements from the request of the compact, light weight, high efficiency, low cost Higher efficiency is required. Tooth root and bottom profiles of cylindrical gears affect bending fatigue life, but they are hard to measure with conventional gear measuring machine(GMM), because GMM is normally customized to measure only gear working flanks. The authors try to develop a new type of GMM by installing an extra 3D scanning probe and control software to measure tooth root and bottom profiles. First, in order to measure in various directions, a 3D scanning probe has been attached to the GMM developed. Next, calibration algorithm has been developed. Deviations of the calibration results are measured and it is found that systematic error must be caused by heat from driving motors. A new alternative GMM with driving motors generating less heat was designed and two GMMs are compared. Finally, 3 Dimension measurement of tooth root and bottom profiles of cylindrical gears is described.

Calibration of Parameters for Predicting Hysteretic Behavior of Diagonally Reinforced Concrete Coupling Beams (반복하중을 받는 대각보강 콘크리트 연결보의 이력거동 예측을 위한 매개변수 결정방법)

  • Koh, Hyeyoung;Han, Sang Whan;Heo, Chang Dae;Lee, Chang Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.6
    • /
    • pp.303-310
    • /
    • 2017
  • The coupled shear wall system with coupling beams is an efficient structural system for high-rise buildings because it can provide excellent ductility and energy dissipation to the buildings. The objective of this study is to simulate the hysteretic behavior of diagonally reinforced concrete coupling beams including pinching and cyclic deteriorations in strength and stiffness using a numerical model. For this purpose, coupling beams are modeled with an elastic beam element and plastic spring element placed at the beam ends. Parameters for the analytical model was calibrated based on the test results of 6 specimens for diagonally reinforced concrete coupling beams. The analytical model with calibrated model parameters is verified by comparing the hysteretic curves obtained from analysis and experimental tests.