• Title/Summary/Keyword: Energy Optimization

Search Result 2,408, Processing Time 0.026 seconds

A Study on the Evolution of Logistics Policy and Response on Low Carbon Economy in China: Focused on 12th 5-Year Plan (중국 물류정책의 변화와 저탄소 경제 대응에 관한 연구 - 제12차 5개년 계획을 중심으로 -)

  • Seo, Su-Wan
    • Journal of Korea Port Economic Association
    • /
    • v.26 no.4
    • /
    • pp.329-353
    • /
    • 2010
  • This paper deal with government logistics policy in related low carbon in China. The government policy of promoting low-carbon way is more dependent on the top-down enforcement rather than voluntary market principles. It will succeeded in transforming the environment-friendly image, to focus on creating a mindset the company can go on voluntary carbon-reduction. The three factors of low-carbon economy and the new energy and industrial development policy is technology and funding, and that most of the government's policy has a crucial role. Due to the nature of the Chinese economy, government policies impact on the development of the industry is very important, and even for China's industrial restructuring of the logistics industry in the areas of government policy support for green economic growth, its role is expected to be very large. In Future, Chinese government will promote low carbon policies through the optimization of the logistics network to reduce energy waste, pursue the low carbon-reduction of logistics machinery and equipment, and develop an mode to appropriate demand for green low-carbon economic growth.

Supercritical Dyeing Technology (초임계 염색 기술)

  • Kim, Taewan;Park, Geonhwan;Kong, Wonbae;Lee, Youn-Woo
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • As the social demands for environmental pollution increase and regulations on the dyeing process wastewater are strengthened, supercritical dyeing process has been attracting attention as an alternative technology to reduce wastewater and energy consumption. In the supercritical dyeing process where carbon dioxide is used as a solvent instead of water as a solvent, there is no wastewater generated. The unfixed dyes can be reused later which makes the process environment-friendly. Also, after dyeing process, dried textiles can be obtained without additional drying process, which makes the process energy efficient. In this article, we have summarized the development of the supercritical dyeing process along with the research in Korea today and compared the principle of supercritical dyeing process with conventional dyeing process. To further explain the principle, studies of the distribution factor and mass transfer of dyes in supercritical carbon dioxide and fibers, as well as solubility between supercritical $CO_2$ and dyes are discussed. The dynamic behavior of dyes in supercritical dyeing apparatus and summary of the supercritical dyeing facilities developed around the world are also discussed. Finally, we suggest the direction of research and development for optimization of supercritical dyeing process and application to synthetic fibers and natural fibers except for polyester.

Computational Optimization of Bioanalytical Parameters for the Evaluation of the Toxicity of the Phytomarker 1,4 Napthoquinone and its Metabolite 1,2,4-trihydroxynapththalene

  • Gopal, Velmani;AL Rashid, Mohammad Harun;Majumder, Sayani;Maiti, Partha Pratim;Mandal, Subhash C
    • Journal of Pharmacopuncture
    • /
    • v.18 no.2
    • /
    • pp.7-18
    • /
    • 2015
  • Objectives: Lawsone (1,4 naphthoquinone) is a non redox cycling compound that can be catalyzed by DT diaphorase (DTD) into 1,2,4-trihydroxynaphthalene (THN), which can generate reactive oxygen species by auto oxidation. The purpose of this study was to evaluate the toxicity of the phytomarker 1,4 naphthoquinone and its metabolite THN by using the molecular docking program AutoDock 4. Methods: The 3D structure of ligands such as hydrogen peroxide ($H_2O_2$), nitric oxide synthase (NOS), catalase (CAT), glutathione (GSH), glutathione reductase (GR), glucose 6-phosphate dehydrogenase (G6PDH) and nicotinamide adenine dinucleotide phosphate hydrogen (NADPH) were drawn using hyperchem drawing tools and minimizing the energy of all pdb files with the help of hyperchem by $MM^+$ followed by a semi-empirical (PM3) method. The docking process was studied with ligand molecules to identify suitable dockings at protein binding sites through annealing and genetic simulation algorithms. The program auto dock tools (ADT) was released as an extension suite to the python molecular viewer used to prepare proteins and ligands. Grids centered on active sites were obtained with spacings of $54{\times}55{\times}56$, and a grid spacing of 0.503 was calculated. Comparisons of Global and Local Search Methods in Drug Docking were adopted to determine parameters; a maximum number of 250,000 energy evaluations, a maximum number of generations of 27,000, and mutation and crossover rates of 0.02 and 0.8 were used. The number of docking runs was set to 10. Results: Lawsone and THN can be considered to efficiently bind with NOS, CAT, GSH, GR, G6PDH and NADPH, which has been confirmed through hydrogen bond affinity with the respective amino acids. Conclusion: Naphthoquinone derivatives of lawsone, which can be metabolized into THN by a catalyst DTD, were examined. Lawsone and THN were found to be identically potent molecules for their affinities for selected proteins.

Ecotoxicity Assessment for Livestock Waste Water Treated by a Low Impact Development(LID) Pilot Plant (파일럿 규모의 LID공법을 적용한 축산폐수 처리수에 대한 생태독성 평가)

  • Park, Da Kyung;Chang, Soon-Woong;Choi, Hanna
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.662-669
    • /
    • 2017
  • This study evaluated the ecotoxicological properties of livestock waste water treated by a LID (Low Impact Development) system, using a mixture of bio-reeds and bio-ceramics as suitable bed media for a subsequent treatment process of a livestock wastewater treatment plant. The relationship between the pollutant reduction rate and the ecotoxicity was analyzed with the effluents from the inlet pilot plant, with vegetated swale and wetlands and the batch type of an infiltration trench. Each pilot plant consisted of a bio process using bio-reeds and bio-ceramics as bed media, as well as a general process using general reeds and a bed as a control group. The results indicated that, after applying the HRT 24 hour LID method, the ecotoxicity was considerably lowered and the batch type pilot plant was shown to be effective for toxicity reduction. The LID method is expected to be effective for water quality management, considering ecotoxicity by not only as a nonpoint source pollution abatement facility but also, as a subsequent treatment process linked with a livestock manure purification facility. It is necessary to take the LID technic optimization study further to apply it as a subsequent process for livestock wastewater treatment.

Dead Layer Thickness and Geometry Optimization of HPGe Detector Based on Monte Carlo Simulation

  • Suah Yu;Na Hye Kwon;Young Jae Jang;Byungchae Lee;Jihyun Yu;Dong-Wook Kim;Gyu-Seok Cho;Kum-Bae Kim;Geun Beom Kim;Cheol Ha Baek;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.129-135
    • /
    • 2022
  • Purpose: A full-energy-peak (FEP) efficiency correction is required through a Monte Carlo simulation for accurate radioactivity measurement, considering the geometrical characteristics of the detector and the sample. However, a relative deviation (RD) occurs between the measurement and calculation efficiencies when modeling using the data provided by the manufacturers due to the randomly generated dead layer. This study aims to optimize the structure of the detector by determining the dead layer thickness based on Monte Carlo simulation. Methods: The high-purity germanium (HPGe) detector used in this study was a coaxial p-type GC2518 model, and a certified reference material (CRM) was used to measure the FEP efficiency. Using the MC N-Particle Transport Code (MCNP) code, the FEP efficiency was calculated by increasing the thickness of the outer and inner dead layer in proportion to the thickness of the electrode. Results: As the thickness of the outer and inner dead layer increased by 0.1 mm and 0.1 ㎛, the efficiency difference decreased by 2.43% on average up to 1.0 mm and 1.0 ㎛ and increased by 1.86% thereafter. Therefore, the structure of the detector was optimized by determining 1.0 mm and 1.0 ㎛ as thickness of the dead layer. Conclusions: The effect of the dead layer on the FEP efficiency was evaluated, and an excellent agreement between the measured and calculated efficiencies was confirmed with RDs of less than 4%. It suggests that the optimized HPGe detector can be used to measure the accurate radioactivity using in dismantling and disposing medical linear accelerators.

Design and Performance Evaluation of Digital Twin Prototype Based on Biomass Plant (바이오매스 플랜트기반 디지털트윈 프로토타입 설계 및 성능 평가)

  • Chae-Young Lim;Chae-Eun Yeo;Seong-Yool Ahn;Myung-Ok Lee;Ho-Jin Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.935-940
    • /
    • 2023
  • Digital-twin technology is emerging as an innovative solution for all industries, including manufacturing and production lines. Therefore, this paper optimizes all the energy used in a biomass plant based on unused resources. We will then implement a digital-twin prototype for biomass plants and evaluate its performance in order to improve the efficiency of plant operations. The proposed digital-twin prototype applies a standard communication platform between the framework and the gateway and is implemented to enable real-time collaboration. and, define the message sequence between the client server and the gateway. Therefore, an interface is implemented to enable communication with the host server. In order to verify the performance of the proposed prototype, we set up a virtual environment to collect data from the server and perform a data collection evaluation. As a result, it was confirmed that the proposed framework can contribute to energy optimization and improvement of operational efficiency when applied to biomass plants.

Study on the optimization of additive manufacturing process parameters to fabricate high density STS316L alloy and its tensile properties (고밀도 STS316L 합금 적층 성형체의 제조공정 최적화 및 인장 특성 연구)

  • Yeonghwan Song
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.6
    • /
    • pp.288-293
    • /
    • 2023
  • To optimize the process parameters of laser powder bed fusion process to fabricate the high density STS316L alloy, the effect of laser power, scanning speed and hatching distance on the relative density was studied. Tensile properties of additively manufactured STS316L alloy using optimized parameters was also evaluated according to the build direction. As a result of additive manufacturing process under the energy density of 55.6 J/mm3, 83.3 J/mm3 and 111.1 J/mm3, high density STS316L specimens was suitably fabricated when the energy density, power and scan speed were 83.3 J/mm3, 225 W and 1000 mm/s, respectively. The yield strength, ultimate tensile strength, and elongation of STS316L specimens in direction perpendicular to the build direction, show the most competitive values. Anisotropic shape of the pores and the lack of fusion defects probably caused strain localization which result in deterioration of tensile properties.

Optimal Configuration of the Truss Structures by Using Decomposition Method of Three-Phases (3단계(段階) 분할기법(分割技法)에 의한 평면(平面)트러스 구조물(構造物)의 형상(形狀) 최적화(最適化)에 관한 연구(硏究))

  • Lee, Gyu Won;Song, Gi Beom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.39-55
    • /
    • 1992
  • In this research, a Three Level Decomposition technique has been developed for configuration design optimization of truss structures. In the first level, as design variables, behavior variables are used and the strain energy has been treated as the cost function to be maximized so that the truss structure can absorb maximum energy. For design constraint of the optimal design problem, allowable stress, buckling stress, and displacement under multi-loading conditions are considered. In the second level, design problem is formulated using the cross-sectional area as the design variable and the weight of the truss structure as the cost function. As for the design constraint, the equilibrium equation with the optimal displacement obtained in the first level is used. In the third level, the nodal point coordinates of the truss structure are used as coordinating variable and the weight has been taken as the cost function. An advantage of the Three Level Decomposition technique is that the first and second level design problems are simple because they are linear programming problems. Moreover, the method is efficient because it is not necessary to carry out time consuming structural analysis and techniques for sensitivity analysis during the design optimization process. By treating the nodal point coordinates as design variables, the third level becomes unconstrained optimal design problems which is easier to solve. Moreover, by using different convergence criteria at each level of design problem, improved convergence can be obtained. The proposed technique has been tested using four different truss structures to yield almost identical optimum designs in the literature with efficient convergence rate regardless of constraint types and configuration of truss structures.

  • PDF

The Research on the Development Potential of Smart Public Facilities in Public Design - Focusing on examples of public facilities in smart cities - (공공디자인에서 스마트 공공시설물의 발전 가능성에 관한 연구 -스마트 도시의 공공시설물 사례를 중심으로-)

  • Son, Dong Joo
    • Journal of Service Research and Studies
    • /
    • v.13 no.4
    • /
    • pp.97-112
    • /
    • 2023
  • Background: In modern society, the importance of Public Design has become increasingly significant in contributing to the enhancement of urban functionality and the quality of life of citizens. Smart Public Facilities have played a pivotal role in enriching user experience by improving accessibility, convenience, and safety, and in elevating the value of the city. This research recognizes the importance of Public Facilities and explores the potential of Smart Public Facilities in solving urban challenges and progressing towards sustainable and Inclusive cities. Method: The literature review comprehensively examines existing theories and research results on Smart Public Facilities. The case study analyzes actual examples of Smart Public Facilities implemented in cities both domestically and internationally, drawing out effects, user satisfaction, and areas for improvement. Through analysis and discussion, the results of the case studies are evaluated, discussing the potential development of Smart Public Facilities. Results: Smart Public Facilities have been found to bring positive changes in various aspects such as urban management, energy efficiency, safety, and information accessibility. In terms of urban management, they play a crucial role in optimization, social Inclusiveness, environmental protection, fostering citizen participation, and promoting technological innovation. These changes create a new form of urban space, combining physical space and digital technology, enhancing the quality of life in the city. Conclusion: This research explores the implications, current status, and functions of Smart Public Facilities in service and design aspects, and their impact on the urban environment and the lives of citizens. In conclusion, Smart Public Facilities have brought about positive changes in the optimization of urban management, enhancement of energy efficiency, increased information accessibility, User-Centric design, increased interaction, and social Inclusiveness. Technological innovation and the integration of Public Facilities have made cities more efficient and proactive, enabling data-based decision-making and optimized service delivery. Such developments enable the creation of new urban environments through the combination of physical space and digital technology. The advancement of Smart Public Facilities indicates the direction of urban development, where future cities can become more intelligent, proactive, and User-Centric. Therefore, they will play a central role in Public Design and greatly contribute to improving the urban environment and the quality of life of citizens.

Optimal Operation of Gas Engine for Biogas Plant in Sewage Treatment Plant (하수처리장 바이오가스 플랜트의 가스엔진 최적 운영 방안)

  • Kim, Gill Jung;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.18-35
    • /
    • 2019
  • The Korea District Heating Corporation operates a gas engine generator with a capacity of $4500m^3 /day$ of biogas generated from the sewage treatment plant of the Nanji Water Recycling Center and 1,500 kW. However, the actual operation experience of the biogas power plant is insufficient, and due to lack of accumulated technology and know-how, frequent breakdown and stoppage of the gas engine causes a lot of economic loss. Therefore, it is necessary to prepare technical fundamental measures for stable operation of the power plant In this study, a series of process problems of the gas engine plant using the biogas generated in the sewage treatment plant of the Nanji Water Recovery Center were identified and the optimization of the actual operation was made by minimizing the problems in each step. In order to purify the gas, which is the main cause of the failure stop, the conditions for establishing the quality standard of the adsorption capacity of the activated carbon were established through the analysis of the components and the adsorption test for the active carbon being used at present. In addition, the system was applied to actual operation by applying standards for replacement cycle of activated carbon to minimize impurities, strengthening measurement period of hydrogen sulfide, localization of activated carbon, and strengthening and improving the operation standards of the plant. As a result, the operating performance of gas engine # 1 was increased by 530% and the operation of the second engine was increased by 250%. In addition, improvement of vent line equipment has reduced work process and increased normal operation time and operation rate. In terms of economic efficiency, it also showed a sales increase of KRW 77,000 / year. By applying the strengthening and improvement measures of operating standards, it is possible to reduce the stoppage of the biogas plant, increase the utilization rate, It is judged to be an operational plan.