• Title/Summary/Keyword: Energy Efficiency Improvement

Search Result 1,002, Processing Time 0.029 seconds

An Analysis on the Improvement Plan of energy efficiency standard for household refrigerator and air conditioner (냉장고와 에어컨의 에너지 효율 기준 개선 방안 분석)

  • Oh, Min-Hyuk;Baek, Jung-Myoung;Lee, Byung-Ha;Kim, Jung-Hoon;Hwang, Sung-Wook;Won, Jong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.216-218
    • /
    • 2006
  • Economy of world has grown rapidly. This growth has increased the ownership of household electrical appliances including room air conditioners. The number of users of air conditioners is predicted to grow dramatically in the future. This paper discusses the present status of residential appliance energy efficiency standards around the world. The study found that the energy efficiency standards for room all conditioners would mitigate a significant amount of emissions in Korea.

  • PDF

Operation characteristics of fast pulse generator using a 2-stage magnetic switch (2단 자기스위치를 사용한 고속 펄스발생기의 동작 특성)

  • 김복권;권순걸;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.10
    • /
    • pp.139-147
    • /
    • 1996
  • In this study a two-stage fast pulse generaor using magnetic switches is proposed. The scheme consist of a switch, an inductor and two pairs of capacitor and saturable inductors, a linear transformer. The basic principle and the operation are described using a set of given parameters. The main issue of the magnetic pulse genration scheme is the system efficiency. This study focuses on the system efficiency improvement using magnetic switches. The voltage compression ratio, energy transfer with respect to core area are investigated. The output voltage and transferred energy as a function of input voltage are also included. Also, an analysis and experiments are performed to verify the porposed topology by implementing a 10[J] class experimental circuit. The efficiency of the transferred energy a tload side is 82%.

  • PDF

Duty Cycle Research for Energy Consumption Efficiency under the IoT Wireless Environment

  • Woo, Eun-Ju;Moon, Yu-Sung;Choi, Ung-Se;Kim, Jung-Won
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1210-1213
    • /
    • 2018
  • In this paper, we propose a method to reduce the amount of current through the Timing Control of the duty cycle and the Report Attribute Control at the MAC Layer in consideration of the Sleep Mode under the IoT wireless environment. The use of a duty cycle is an effective way to reduce energy consumption on wireless sensor networks where the node is placed in sleep mode periodically. In particular, we studied how to control power efficiency through duty rate in Short Transition Time and ACK Time processing while satisfying radio channel limitation criterion. When comparing before and after the improvement considering the delay time constraint, we validated the correlation of the electrical current reduction.

A Study on the Improvement of Distance Range for Medium Tactical Vehicle (중형전술차량의 항속거리 향상 방안 연구)

  • Lee, HyungChae
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.30-36
    • /
    • 2019
  • The military has developed and operated a variety of military vehicles. Among them, medium tactical vehicles are developed as vehicles suitable for transporting troops, replacing existing military trucks, which have a significant impact on infantry forces' combat capability. Applying technology to increase fuel efficiency to these critical weapons systems, medium tactical vehicles, increases the distance range, which can reduce effective operational performance and oil costs. In this study, a measure was taken to improve the distance range of Medium Tactical Vehicles by applying an oil temperature control strategy to increase fuel efficiency.

An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions (부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구)

  • Choi, Sungkyung;Lee, Sang Hun;Kim, Sunjae;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.

Performance Improvement of Flexible Thin Film Si Solar Cells using Graphite Substrate (그라파이트 기판을 이용한 유연 박막 실리콘 태양전지 특성 향상)

  • Lim, Gyeong-yeol;Cho, Jun-sik;Chang, Hyo Sik
    • Korean Journal of Materials Research
    • /
    • v.29 no.5
    • /
    • pp.317-321
    • /
    • 2019
  • We investigated the characteristics of nano crystalline silicon(nc-Si) thin-film solar cells on graphite substrates. Amorphous silicon(a-Si) thin-film solar cells on graphite plates show low conversion efficiency due to high surface roughness, and many recombination by dangling bonds. In previous studies, we deposited barrier films by plasma enhanced chemical vapor deposition(PECVD) on graphite plate to reduce surface roughness and achieved ~7.8 % cell efficiency. In this study, we fabricated nc-Si thin film solar cell on graphite in order to increase the efficiency of solar cells. We achieved 8.45 % efficiency on graphite plate and applied this to nc-Si on graphite sheet for flexible solar cell applications. The characterization of the cell is performed with external quantum efficiency(EQE) and current density-voltage measurements(J-V). As a result, we obtain ~8.42 % cell efficiency in a flexible solar cell fabricated on a graphite sheet, which performance is similar to that of cells fabricated on graphite plates.

The Analysis on Energy Performance according to Characteristics of Glazing in High-rise Office Buildings (Glazing 특성에 따른 고층 오피스 건물의 에너지성능 분석)

  • Hwang, Woo-Jin;Kim, Kyo-Joon;Choi, Won-Ki
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.156-161
    • /
    • 2011
  • In case of newly constructed buildings, the construction type is almost Curtain-wall system or large window in building skin. However, these kind of buildings have problems with regulations on building energy efficiency. And national regulations on building energy efficiency limit only the V-factor of window(except infiltration), it is hard to predict energy consumption of Curtain-wall buildings which gain large solar energy in summer. In this study, the influence of LSG(Light to Solar Gain) on energy performance was theoretically analyzed with simulation. LSG is the value of VLT divide SHGC and represents the optical performance of the glass or glazing. The Window & Therm program developed in LBNL was used to analyze window systems and EnergyPlus was used to building energy. Cases of glazing are three types; single coated Low-e clear glazing, tripple coated Low-e clear glazing, tripple coated Low-e tinted glazing. The results of this study are follows; 1) The building energy consumption of Alt-l, 2, 3 were about 300, 253, $259kWh/m^2{\cdot}yr$ respectively. Therefore, improvement of LSG could save the energy up to 16%. 2) The saved energy could be converted 1 billion won as annual benefit of total energy costs 3) SHGC and LSG more influence on cooling energy than heating energy in office buildings.

  • PDF

A Study on the Energy Efficiency of a Geothermal Heat Pump System in use the Outdoor Reset Control Application (외기보상제어 적용에 따른 지열 히트펌프 시스템의 에너지 효율 향상에 관한 연구)

  • Jung, Young-Ju;Kim, Hyo-Jun;Lee, Yong-Ho;Hwang, Jung-Ha;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • The government is fostering a renewable energy industry as an alternative to handle the energy crisis. Among the renewable energy systems available, geothermal energy is being highlighted as being highly efficient and safely operable without the effect of outdoor air. Accordingly, a study on the geothermal heat pump is in progress in various worldwide perspective. However, Geothermal energy is only in charge of part load of the building due to the high initial installation cost in korea. Moreover, its efficiency is reduced due to the use of independent existing heat sources. In this study, after selecting the building containing the actual installed geothermal heat pump, the use of excellent geothermal heat pump systems was maximized in terms of the energy efficiency. The objective of this study is to show the operation method of geothermal heat pump system to improve energy efficiency through the TRNSYS simulation. This paper proposed operation methods of geothermal heat pump control according to outdoor air temperature. The result of this study is that existing operation method had some problems and if offered improvement is applied to real condition, energy consumption would be decreased.

Energy Analysis of A Combined Heat and Power Plant (엑서지분석에 의한 열병합발전의 효율제고에 관한 연구)

  • 오영삼;김종진;최기련;목영일
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.83-94
    • /
    • 1993
  • In this paper, the performance of an energy conversion system is analyzed using two efficiency concepts, one of conventional and the other of energetic efficiently. The objective of this analysis was to improve and optimize the energy conversion system in point, namely, and LNG-fired Combined Heat and Power Plant (CHP). To this end, energies which represent the true efficiency figures were evaluated for various flows of the system with a set of system configurations given. Then the economic values of the energies were assigned to respective flows and subsystems. With these economic data locations of inefficiencies and opportunities for improvement are identified.

  • PDF