• Title/Summary/Keyword: Energy Consumption Unit

Search Result 355, Processing Time 0.026 seconds

A Study on the Operational Strategy for Hybrid Ventilation System in Apartment unit focused on Indoor Air Quality (실내공기질을 고려한 공동주택의 하이브리드 환기 시스템의 운영에 관한 연구)

  • Lee, Yong-Jun;Leigh, Seung-Bok;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.203-210
    • /
    • 2004
  • This dissertation identifies and investigates the possible control modes of hybrid ventilation system in applying to general apartments. It evaluates range of hybrid ventilation control modes in terms of indoor air quality, thermal comfort, and energy consumption in a living room and a kitchen of the $1000m^2$ apartment. The TRNSYS simulation program was used for evaluating the following four ventilation types : A ventilation mode relying on only infiltration for supplying air, A natural ventilation mode considering with weather condition, A hybrid ventilation (natural + mechanical ventilation) mode allowing minimum ventilation with no heat exchange, and a hybrid ventilation mode with heat exchange. This study shows the following results. As temperature being controlled by heating cooling equipments, there is without significant difference in thermal performance among ventilation types. Regarding Indoor Air quality, Indoor air contamination level of the hybrid ventilation case consistently keep the lower levels. The hybrid ventilation modes consume more energy by a 49% as compared to the A ventilation mode relying on only infiltration for supplying air. It is caused by the continuous ventilation for keeping good indoor air quality; the increase of energy consumption can be attributable to the increase of the heating energy. Therefore, the heat exchange between indoor and outdoor air is required during heating season in severe weather conditions. During the cooling seasons, Introducing natural ventilation can achieve energy saving by 40 ~ 45%. Thus, it can be an effective strategies for energy saving. Based on these results, a hybrid ventilation system can be suggested as an effective ventilation strategy for archiving high level of indoor air quality, thermal comfort, and energy consumption.

An Analysis on Characteristics and the Development of Estimation Model of Internal Heat Gain from Appliances in Apartment Units (공동주택 단위세대의 기기발열 특성 분석 및 추정모델 개발)

  • Lee, Soo-Jin;Jin, Hye-Sun;Kim, Sung-Im;Lim, Han-Young;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.10
    • /
    • pp.19-26
    • /
    • 2018
  • The purpose of this study was to analyze characteristics and to develop estimation model of IHG(Internal Heat Gain) from appliance in domestic apartment units. To do this, it was defined the source of IHG from appliance and the calculation method through the case study of international and domestic codes. And the equipment related datum such possession, usage or not, etc were collected through field survey in apartment units, and the appliances' electricity consumption were measured separately from overall electricity consumption. Annual electricity consumption value were calculated with field survey datum and appliances' electricity consumption measurement datum, and then IHG value was calculated by applying PHPP v9 method. And it was conducted correlation analysis between IHG value and the area for exclusive use, the number of occupants, and then the IHG from applianace estimation model was deducted with regression analysis. Finally, it was analyzed the present level and of the domestic code(The Building Energy Efficiency Rating System) comparing with the value of estimation model, and the various international codes(HERS, Building America, SAP).

A Study on the Effect Analysis of the Tilting Technology According to the Evaluation of Electric Power Consumption Energy of Rolling Stock (철도차량 소비전력량 평가에 따른 틸팅기술 효과분석)

  • Kim, Dae-Sik;Lee, Ki-Jun
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.329-333
    • /
    • 2012
  • In this paper, By the time that the tilting technology is adopted in railway rolling stock, we analyzed quantitatively energy saving by reducing the power consumption with the reduction of the operation time through the speed improvement and suggested the necessity to introduce tilting technology in the domestic rail vehicles. To achieve this purpose, the effect of energy saving by comparing and analyzing the power consumption during the operation by TTX HANVIT 200 and 8200 electric locomotives to pull the trains on the same line was suggested and the efficiency of the main devices was compared and analyzed by measuring the power consumption by a single unit. As the energy saving is the world topic, the studies on reducing energy usage goes on constantly in many areas. In addition, as of the time to improve the conventional tracks to speed up and change the signals, Tilting technology will be contributed to the management environment by enlarging the passengers' demand through the reduction of the operation time and saving energy using the existing infrastructure.

Estimating China Long-run Energy Demand Functions with Cointegration Approaches (중국의 중장기 에너지 수요함수 추정 및 비교분석)

  • Jung, Sukwan;Yang, Yu;Won, DooHwan
    • International Area Studies Review
    • /
    • v.20 no.3
    • /
    • pp.3-22
    • /
    • 2016
  • This paper uses Dynamic OLS(DOLS) approach to estimate the long-run energy demand functions. The results are compared with those of standard cointegration approach. Cointegration tests verify that there is a cointegration among energy consumption, real GDP, and energy price in China. Johansen approach and DOLS approach are more appropriate to estimate for the long-run energy demand function than Engle-Granger Cointegration approach. DOLS provided significant negative sign of price while Engle-Granger did not. Based on the DOLS results, the elasticities of real GDP and energy price on energy consumption are 0.83 and -0.45 respectively, and their statistical significances are high.

Dynamic Analysis of Cool Thermal Storage Air Conditioning System (빙축열 에어컨의 동적 사이클 해석)

  • Koh, Jae-Yoon;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.65-74
    • /
    • 2008
  • In this study, dynamic characteristics analysis of AC system is investigated using a cool thermal storage system. A analysing program for cool thermal storage AC system is developed. The performances are studied by several variables and dynamic characteristics. Comparing the result at conventional operation condition with that at the condition using ice storage system, this study showed the effects of the sub cooled degree, superheated degree, efficiency of compressor and evaporating temperature. At the condition using thermal storage system, the thermal storage process was operated during midnight being not needed the cooling of the AC unit through the continuous running of the condenser. The refrigerant was sub-cooled using stored energy after being discharged from the air source condenser during the daytime. The COP was increased owing to the sub-cooling of refrigerant during daytime, thus the power consumption was effectively decreased.

Comparative studies of gasification potential of agro-waste with wood and their characterization

  • Tripathi, Amarmani;Shukla, S.K.
    • Advances in Energy Research
    • /
    • v.3 no.3
    • /
    • pp.181-194
    • /
    • 2015
  • In this work, an experimental study of the gasification on wood was carried out in downdraft type fixed bed Gasifier attached with 10 kW duel fuel diesel engine. The main objective of the study was to use wood as the biomass fuel for downdraft Gasifier and to evaluate the operating parameter of gasifier unit to predict its performance in terms of gas yield and cold gas efficiency. The influence of different biomass on fuel consumption rate, gas yield and cold gas efficiency was studied. Composition of producer gas was also detected for measuring the lower heating value of producer gas to select the feed stock so that optimum performance in the existing gasifier unit can be achieved. Under the experimental conditions, Lower heating value, of producer gas, cold gas efficiency and gas yields, using wood as a feed stock, are $4.85MJ/m^3$, 46.57% and $0.519m^3/kg$.

Annual Energy Performance Evaluation of Zero Energy House Using Metering Data (실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가)

  • Lim, Hee-Won;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

Experimental Study on Hydrogen Direct Reduction of Hematite in a Lab Scale Fluidized Bed Reactor by Estimating the Gas Consumption Rate

  • Hasolli, Naim;Jeon, Seong Min;Park, Young Ok;Kim, Yong Ha
    • Clean Technology
    • /
    • v.21 no.2
    • /
    • pp.96-101
    • /
    • 2015
  • Hematite reduction using hydrogen was conducted and the various process parameters were closely observed. A lab scale fluidized bed unit was designed especially for this study. The optimal values of the gas velocity, reduction time and temperature were evaluated. The values which indicated the highest reduction rate were set as fixed parameters for the following tests starting with the reduction time of 30 minutes and 750 ℃ of temperature. Among these variables the one with the highest interest was the gas specific consumption. It will tell the amount of the gas which is required to achieve a reduction rate of over 90% at the optimal conditions. This parameter is important for the scale up of the lab scale unit. 1,500 Nm3/ton-ore was found to be the optimal specific gas consumption rate at which the reduction rates exhibit the highest values for hematite.

Analytic Study on the Design Elements for Energy Conservative Green-Home Prototyping (에너지 저감형 그린홈 프로토타이핑을 위한 설계요소 분석 연구)

  • Kim, Jung-Eun;Chang, Seong-Ju;Ha, Mi-Kyoung;Sung, Hae-Yoen;Kim, Kyung-Wan
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.63-70
    • /
    • 2011
  • In respond to the global energy crisis and climate change, there have been many ongoing national efforts to develop a sustainable housing prototype followed by "2 million Green Home Project" in Korea. More than 50% of nation's population are currently living in apartment housing thus the country is seriously in need of developing green apartment prototype. In this research, we focused on energy-conservative green apartment design prototype that have both passive components and active systems explored in a systemic design approach. After selecting an existing basic apartment unit, we analyzed and compared statistical data with the simulated annual energy consumption to match these two data sets for validating simulation accuracy performed with TRNSYS package. We performed energy simulations with different passive design factors such as varied insulation thickness, window types and infiltration rates as well as the active design factors including boilers and lighting fixtures to analyze their impacts on the energy performance of the housing unit using TRNSYS software. As a result, we acquired significant energy reduction effect with explored design strategies but the life cycle cost analysis for the final design guidline would need to be performed. In this study, we focused on a systematic comparative energy analysis based on TRNSYS that can improve the design of a green apartment housing.

Analysis of the Hardware Structures of the IoT Device Platforms for the Minimal Power Consumption (소비 전력 최소화를 위한 IoT 디바이스 플랫폼의 하드웨어 구조 분석)

  • Lee, Jin
    • Journal of Internet of Things and Convergence
    • /
    • v.6 no.2
    • /
    • pp.11-18
    • /
    • 2020
  • Since the end devices of the Internet of Things (IoT) are battery operated products, careful consideration for ultra-low power (ULP) is required. The Micro Controller Unit (MCU) industry has developed very effective functions to save energy, but developers have difficulty in selecting the MCU because various operating modes are applied to reduce energy consumption by manufacturers. Therefore, this paper introduces ULPMark benchmark, a standardized benchmark method that can compare MCUs of various vendors and feature sets, and provides hardware functions for ultra-low-power operation of the two platforms that received the high evaluation scores from ULPMark. In addition, we investigated and analyzed how developers can utilize the functions for ultra low power consumption through driver APIs and detailed register control.