• 제목/요약/키워드: End-load

검색결과 1,423건 처리시간 0.024초

원자로용 하단고정체에 대한 구조시험 평가 (Evaluation of Structural Test for Bottom End Piece Used for Nuclear Power Reactor)

  • 김재훈;사정우;김덕회;손동성;임정식
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.3-11
    • /
    • 1999
  • The atomic fuel rods between top and bottom end pieces of reactor need to be extended for high combustion rate of future-type fuel to increase the irradiation in the axial direction. For allowing axial extension of the fuel rods, the space between top and bottom end pieces should be expanded. Thus the thickness reduction of the flow plate is necessary. This study was carried out the mechanical strength test by using strain gages as a function of flow plate thickness, the existence of skirt and loading condition for the Korean Fuel Assembly(KOFA). The experimental apparatus was designed for load conditions, uniformly distributed load and displacement. Test method using whiffle tree of uniformly distributed load has been comparatively conservative. The test results were compared with those of finite element analysis and the test method on bottom end piece was established.

  • PDF

엔드밀 가공의 절삭력 예측 및 실험 (Prediction and Experiments of Cutting Forces in End Milling)

  • 이신영;임용묵
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.9-15
    • /
    • 2004
  • A reasonable analysis of cutting force in end milling may give much advantage to improvement of productivity and cutting tool life. In order to analyze cutting force, the cutting dynamics was modelled mathematically by using chip load, cutting geometry, and the relationship between cutting forces and the chip load. The specific cutting constants of the cutting dynamics model were obtained by average cutting forces, tool diameter, cutting speed, feed, axial depth, and radial depth of cut. The model is verified through comparisons of model predicted cutting forces with measured cutting forces obtained from machining experiments. The results showed good agreement and from that we could predict reasonably the cutting forces in end milling.

모듈형 복합재 전두부가 적용된 전동차의 구조해석 연구 (A Study on Structural Analysis of an Aluminum Electric Motor Car with a Modular Front End made of composite materials)

  • 노규석;구정서;이현순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.247-252
    • /
    • 2001
  • In this study, an aluminum electric motor car with a modular front end made of composite materials is numerically evaluated applying the standard specifications for the urban EMU(Electric Multiple Unit) train. Structural analyses under compressive load, torsional load and free vibration satisfy the standard specifications, but analysis under normal load doesn't. By the way, the aluminum bodyshell of the car except the modular front end is almost same to that of the Korean standard EMU, which satisfy the standard specifications. It is presumed that the stiffness of the modular front end made of composite materials haves some influence on the strength of the aluminum bodyshell.

  • PDF

모듈형 복합재 전두부가 적용된 알루미늄 차체의 구조해석 연구 (A Study on Structural Analysis of An Aluminum Bodyshell with A Modular Front End Made of Composite Materials)

  • 구정서;조현직;한형석
    • 한국철도학회논문집
    • /
    • 제6권4호
    • /
    • pp.273-278
    • /
    • 2003
  • In this study, an aluminum bodyshell with a modular front end made of composite materials is numerically evaluated applying the standard specifications for the urban EMU (Electric Multiple Unit) train. Structural analyses under compressive load, torsional load and free vibration satisfy the standard specifications, but analysis under normal load doesn't. By the way, the aluminum bodyshell of the car except the modular front end is almost same to that of the Korean standard EMU, which satisfy the standard specifications. It is presumed that the stiffness of the modular front end made of composite materials has some influence on the strength of the aluminum bodyshell.

수용가 부하곡선을 일용한 국제분쟁시 전력사용 행태분석 (An analysis of the End-User electric power consumption trends using the load curve during international conflict)

  • 손학식;김인수;박용욱;임상국;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.165-167
    • /
    • 2004
  • End-user electric power consumption trends shows various load curves dependant on industry, contract, season, day and time. Analysis of end-user electric power consumption trends has a key role to efficiently meet electricity demand. There are several factors of change in electricity demand such as the change of weather, international conflict, and industrial trends during summer. This paper has analyzed the analysis the end-user electric power consumption trends using the load curve during international conflict. We observed that international conflict decreased electric demand by $5.4\%$. This increase is not significant, and therefore we conclude that the international conflict has not greatly affected Korea's electricity demands. This paper provides useful information so as to mon: efficiently perform demand side management.

  • PDF

A Reconfigurable Directional Coupler Using a Variable Impedance Mismatch Reflector for High Isolation

  • Lee, Han Lim;Park, Dong-Hoon;Lee, Moon-Que
    • Journal of electromagnetic engineering and science
    • /
    • 제16권4호
    • /
    • pp.206-209
    • /
    • 2016
  • This letter proposes a reconfigurable directional coupler that uses a variable impedance mismatch reflector to achieve high isolation characteristics in the antenna front end. The reconfigurable coupler consists of a directional coupler and a single-pole four-throw (SP4T) switch with different load impedances as a variable load mismatch reflector. Selection of the load impedance by the reflector allows cancellation of the reflected signal due to antenna load mismatch and the leakage from the input to isolation port of the directional coupler, resulting in high isolation characteristics. The performance of the proposed architecture in separating the received (Rx) signal from the transmitted (Tx) signal in the antenna front end was verified by implementing and testing the reconfigurable coupler at 917 MHz for UHF radio-frequency identification (RFID) applications. The proposed reconfigurable directional coupler showed an improvement in the isolation characteristics of more than 20 dB at the operation frequency band.

전력산업 경쟁 환경에서의 요금부하모델 수립을 위한 부하기기의 학습곡선 분석 (Analysis on learning curves of end-use appliances for the establishment of price-sensitivity load model in competitive electricity market)

  • 황성욱;김정훈;송경빈;최준영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.386-388
    • /
    • 2001
  • The change of the electricity charge from cost base to price base due to the introduction of the electricity market competition causes consumer to choose a variety of charge schemes and a portion of loads to be affected by this change. Besides, it is required the index that consolidate the price volatility experienced on the power exchange with gaming and strategic bidding by suppliers to increase profits. Therefore, in order to find a mathematical model of the sensitively-responding-to-price loads, the price-sensitive load model is needed. And the development of state-of-the-art technologies affects the electricity price, so the diffusion of high-efficient end-uses and these price affect load patterns. This paper shows the analysis on learning curves algorithms which is used to investigate the correlation of the end-uses' price and load patterns.

  • PDF

차체구조용 박육부재의 단면형상변화에 따른 에너지흡수 특성 (Energy Absorbing Characteristics of Thin-Walled Members for Vehicles Having Various Section Shapes)

  • 차천석;정진오;이길성;백경윤;양인영
    • 한국정밀공학회지
    • /
    • 제20권10호
    • /
    • pp.177-182
    • /
    • 2003
  • The front-end side members of automobiles absorb most of the energy in a case of front-end collision. The front-end side members are required to have a high stiffness together with easiness to collapse sequentially to absorb more impact energy. The axial static collapse test (5mm/min) was conducted by using UTM for form different types of members which have different cross section shapes; single hat, single cap, double cap, and double hat. The single hat shaped section member has the typical standard section, which the double hat shape section has a symmetry in the center to have more stiffness. As a result of the test, the energy absorbing characteristic was analyzed for different section shapes. It turned out that the change of section shape influence the absorbing energy, the mean collapse load and the maximum collapse load, and the relation between the change of section shape and the collapse mode.

End shape and rotation effect on steel pipe pile installation effort and bearing resistance

  • Saleem, Muhammad A.;Malik, Adnan A.;Kuwano, Jiro
    • Geomechanics and Engineering
    • /
    • 제23권6호
    • /
    • pp.523-533
    • /
    • 2020
  • The current study focuses on the effect of the end shape of steel pipe piles on installation effort and bearing resistance using the pressing method of installation under dense ground conditions. The effect of pile rotation on the installation effort and bearing resistance is also investigated. The model steel piles with a flat end, cone end and cutting-edge end were used in this study. The test results indicated that cone end pile with the pressing method of installation required the least installation effort (load) and showed higher ultimate resistance than flat and cutting-edge end piles. However, pressing and rotation during cutting-edge end pile installation considerably reduces the installation effort (load and torque) if pile penetration in one rotation equal to the cutting-edge depth. Inclusion of rotation during pile installation reduces the ultimate bearing resistance. However, if penetration of the cutting-edge end pile equal to the cutting-edge depth in one rotation, the reduction in ultimate resistance can be minimized. In comparing the cone and cutting-edge end piles installed with pressing and rotation, the least installation effort is observed in the cutting-edge end pile installed with penetration rate equal to the cutting-edge depth per rotation.

A New SVM Method to Reduce Common-Mode Voltage of Five-leg Indirect Matrix Converter Fed Open-End Load Drives

  • Tran, Quoc-Hoan;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.641-652
    • /
    • 2017
  • This paper proposes a cost-effective topology to drive a three-phase open-end load based on a five-leg indirect matrix converter (IMC) and a space vector modulation (SVM) method. By sharing an inverter leg with two load terminals, the proposed topology can reduce the number of power switches when compared to topologies based on a direct matrix converter or a six-leg IMC. The new SVM method uses only the active vectors that do not produce common-mode voltage (CMV), which results in zero CMV across the load phase and significantly reduces the peak value of the CMV at the load terminal. Furthermore, the proposed drive system can increase the voltage transfer ratio up to 1.5 and provide a superior performance in terms of an output line-to-line voltage with a three-level pulse-width modulation waveform. Simulation and experimental results are given to verify the effectiveness of the proposed topology and the new SVM method.