• Title/Summary/Keyword: Enclosure chamber

Search Result 41, Processing Time 0.026 seconds

An Experimental Study on Acoustic Absorption in a Model Chamber with a Half-Wave Resonator (반파장 공명기를 장착한 모형연소실의 흡음특성에 대한 실험적 연구)

  • Sohn, Chae-Hoon;Park, Ju-Hyun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.3
    • /
    • pp.34-40
    • /
    • 2008
  • Acoustic design parameters of a half-wave resonator are studied experimentally for acoustic stability in a model chamber. According to the standard acoustic-test procedures, acoustic-pressure signals are measured. Quantitative acoustic properties of damping factor and sound absorption coefficient are evaluated and thereby, the acoustic-damping capacity of the resonator is examined. The diameter and the number of a half-wave resonator, its distribution, and the diameter of an enclosure are selected as the design parameters for optimal tuning of the resonator. Aroustic-damping capacity of the resonator increases with its diameter. When the open-area ratio of the resonator exceeds the optimum value, over-damping appears, leading to the decrease in the peak absorption coefficient and the broadening of absorption bandwidth. As the resonator diameter increases, optimum open-area ratio decreases.

THE NUMERICAL SIMULATION OF HYDROGEN JET DIFFUSION FOR HYDROGEN LEAKAGE IN THE ENCLOSED GEOMETRY (밀폐공간에서 수소 누설로 인한 수소 제트 확산에 대한 수치해석)

  • Ahn, Hyuk-Jin;Lee, Sang-Hyuk;Hur, Nahm-Keon;Lee, Moon-Kyu;Yong, Gee-Joong
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.32-38
    • /
    • 2009
  • In the present study, a numerical simulation for the diffusion of hydrogen jet in a enclosure was performed to aid the leakage test of the hydrogen for the safety of the hydrogen vehicle. The temporal and spatial distributions of the hydrogen concentration in the test chamber are predicted from the present numerical analyses. Flammable region of 4-74% and explosive region of 18-59% hydrogen by volume was identified from the present results. Factors influencing the diffusion of the hydrogen jet were examined to evaluate the effectiveness of forced ventilation for relieving the accumulation of the leaked hydrogen gas in the chamber, which include location of open windows, size of leakage nozzle, and leakage rate among others. The distribution of the concentration of the leaked hydrogen for various cases can be used as a database in various applications for the hydrogen safety.

BVOCs Estimates Using MEGAN in South Korea: A Case Study of June in 2012 (MEGAN을 이용한 국내 BVOCs 배출량 산정: 2012년 6월 사례 연구)

  • Kim, Kyeongsu;Lee, Seung-Jae
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.1
    • /
    • pp.48-61
    • /
    • 2022
  • South Korea is quite vegetation rich country which has 63% forests and 16% cropland area. Massive NOx emissions from megacities, therefore, are easily combined with BVOCs emitted from the forest and cropland area, then produce high ozone concentration. BVOCs emissions have been estimated using well-known emission models, such as BEIS (Biogenic Emission Inventory System) or MEGAN (Model of Emission of Gases and Aerosol from Nature) which were developed using non-Korean emission factors. In this study, we ran MEGAN v2.1 model to estimate BVO Cs emissions in Korea. The MO DIS Land Cover and LAI (Leaf Area Index) products over Korea were used to run the MEGAN model for June 2012. Isoprene and Monoterpenes emissions from the model were inter-compared against the enclosure chamber measurements from Taehwa research forest in Korea, during June 11 and 12, 2012. For estimating emission from the enclosed chamber measurement data. The initial results show that isoprene emissions from the MEGAN model were up to 6.4 times higher than those from the enclosure chamber measurement. Monoterpenes from enclosure chamber measurement were up to 5.6 times higher than MEGAN emission. The differences between two datasets, however, were much smaller during the time of high emissions. More inter-comparison results and the possibilities of improving the MEGAN modeling performance using local measurement data over Korea will be presented and discussed.

Three-phase Making Test Method for Common Type Circuit Breaker

  • Ryu, Jung-Hyeon;Choi, Ike-Sun;Kim, Kern-Joong
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.778-783
    • /
    • 2012
  • The synthetic short-circuit making test to adequately stress the circuit breaker has been specified as the mandatory test duty in the IEC 62271-100. The purpose of this test is to give the maximum pre-arcing energy during making operation. And this requires the making operation with symmetrical short-circuit current that is established when the breakdown between contact gap occurs near the crest of the applied voltage. Also, if the interrupting chamber of circuit breakers is designed as the type of common enclosure or the operation is made by the gang operated mechanism that three-phase contacts are operated by one common mechanism, three-phase synthetic making test is basically required. Therefore, several testing laboratories have developed and proposed their own test circuits to properly evaluate the breaker performance. With these technical backgrounds, we have developed the new alternative three-phase making circuit.

Dynamic Characteristics Research of DVD Disk due to Disk-Wall Gap (간격 변화에 따른 DVD 디스크의 동특성 연구)

  • 임효석;이승엽
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1095-1100
    • /
    • 2003
  • Experimental studies on the aerodynamic coupling effect on natural frequencies, critical speed and flutter instability of DVD disks are investigated in this paper. The experimental results are compared with the theoretical analyses where the aerodynamic effects are represented in terms of elastic, lift and damping and stiffness components. The experiments are performed using a vacuum chamber and DVD disks rotating in vacuum, open and enclosure with several different gaps between disk and wall. The following three results are given. One is that the aerodynamic effect by the surrounding air reduces the natural frequencies and critical speeds of the vibration modes. The second is that natural frequency decreases as the disk-wall gap is decreased. Finally, it is shown that the disk vibration is reduced as the gap between the disk and the rigid wall decreases.

  • PDF

The Bouncing Characteristics of Particles in GIS Chamber (GIS가스 챔버 내에서 파티클 부상특성)

  • Lee, Kang-Soo;Kwak, Hee-Ro;Cho, Yong-Woo;Kim, Kyong-Hwa;Cho, Kook-Hee;Kweon, Dong-Jin;Jun, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1850-1852
    • /
    • 1997
  • In this paper, the behavior and effect of conducting particles in a $SF_6$ insulated electrode system, are presented. It is shown that the bouncing voltage of the particle is independent of particle length, and that the breakdown voltages are affected by the particle length. The longer the particle, the lower the breakdown voltages. The bouncing-off, the lift off and breakdown voltages increase as the particle diameter increase. The breakdown voltage of free particle is lower than fixed particle on the enclosure.

  • PDF

Simulation and Experimental Study for Energy Flow Dynamics of Floor Radiant Heating System (바닥복사 난방시스템의 에너지 유동특성에 관한 시뮬레이션 및 실험적 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob;Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.927-932
    • /
    • 2006
  • A simulation and experimental study for energy flow dynamics of floor radiant heating system were performed. The study was done under both environmental chamber and a house with several rooms. The unsteady energy analysis method using equivalent R-C circuit and radiation heat transfer analysis of enclosure analysis method with simple structured rooms were used for computer simulation. Also, first order dynamics with time delay in analyzing the return water was considered. The results of temperature changes of the simulation study are good fit with the ones of experimental one.

  • PDF

전자파 잔향실 및 야외시험장의 복사 방출 측정결과의 상관성 추출

  • 이중근
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.31-37
    • /
    • 2002
  • 전자파 잔향실(Reverberating Shielded Enclosure)의 개념은 전자파 차폐실(Shielded Enclosure)에서 얻어진 측정결과를 개선하기 위하여 1968년도에 제안되었다. 이후 Reverberating 또는 Mode-Stirred Chamber는 EM Immunity 측정뿐만 아니라 EMI측정에서도 많이 적용되어 왔지만, 국제 표준 방식으로 적용되어 오지 못하다가 최근 EMI 복사 전력 측정 및 EM Immunity 측정시설로 유용하게 사용될 수 있다는 점이 부각되어 국제 표준 방식으로 적용하자는 분위기가 무르익어 이에 대한 활발한 논의가 계속되어 오고 있다. 이러한 전자파 잔향실을 이용하여 EMI 및 EMS 시험을 실시할 수 있는 방법을 규격화시키자는 제안이 '96년 프랑스 Mandelieu 국제 전자파 장해 특별위원회(CISPR:International Special Committee on Radio Interference)회의에서 검토된 후 '97년 일본 Yokosuka CISPR 회의에서 정식의제로 채택되었다. 이 안건에 대하여 대부분의 국가들이 제안 취지에 찬성하여 NWIP(New Work Item Proposal) 문서가 각국에서 회람되었다. 초기 전자파 잔향실은 전자파 장해 및 복사 내성 측정을 위한 대용시험 시설로서 1968년 미국 Mendes에 의해 전자파 차폐실 구조에 Stirrer를 이용하여 필드의 균일도를 확보할 수 있다는 전자파 잔향실 개념이 처음으로 제안되었다. 이후 이 분야의 연구는 미국 표준 기술 연구소(NIST: National Institute of Standard and Technology)등에서 연구가 활발히 진행되고 있으며, 국제 표준화 기구인 CISPR에서 전자파 장해 및 내성 시험을 위한 대용시험 시설로서 활용하기 위하여 규격 작업이 진행중에 있다. 또한 최근 전자파 장해 방지를 위한 규제 주파수가 1∼18㎓ 까지 확장됨에 따라 이 주파수 대역에서 시험장으로 활용할 수 있는 전자파 잔향실이 새롭게 부각되고 있다. 전자파 잔향실은 기본적으로 공진 모드를 활용하기 때문에 일정한 크기의 잔향실 내부에서 전자파 균일성을 확보할 수 있는 모드 수에 의해 하한 주파수가 결정되며 충분한 모드 분포상태에서 Stirrer를 사용하여 필드 경계를 이동시킴으로서 확률적으로 균일한 필드분포를 확보하게 된다. 주파수가 증가함에 따라 모드수는 증가하기 때문에 하한 주파수 이상의 대역에 대한 시험시설로 활용할 수 있으며, 특히 ㎓ 대역에서 사용하기에 적합한 대용시험시설이라고 볼 수 있다.

The Application of Fiber-Reinforced Composites to Electromagnetic Wave Shielding Enclosures (섬유강화 복합재료의 전자파 차폐 기구물에 대한 적용에 관한 연구)

  • Park Ki-Yeon;Lee Sang-Eui;Lee Won-Jun;Kim Chun-Gon;Han Jae-Hung
    • Composites Research
    • /
    • v.19 no.3
    • /
    • pp.1-6
    • /
    • 2006
  • As the structures of the high performance electronic equipments and devices recently become more complex, the electromagnetic interference (EMI) and compatibility (EMC) have been very essential for commercial and military purposes. Thus, sensitive electrical devices and densely packed systems need to be protected from electromagnetic wave. In this research, glass fabric/epoxy composites containing conductive multi-walled carbon nanotube (MWNT) and carbon fiber/epoxy composites as electrical shielding materials were fabricated and electrical properties of the composites were measured. The concerning frequency band is from 300 MHz to 1 GHz. The performances of composite shielding enclosures were predicted using electromagnetic wave 3-D simulation tool, CST Microwave Studio. The shielding enclosure made of carbon fiber/epoxy composites were fabricated and the shielding effectiveness (SE) was measured in the anechoic chamber.

The partial discharge and breakdown phenomena due to metallic particle in $SF_6$ gas chamber ($SF_6$ 가스챔버내 금속이물에 대한 부분방전 및 절연파괴 현상)

  • 이재걸;곽희로;조국희;박중신
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.75-81
    • /
    • 2000
  • This paper describes the partial discharge due to particles in $SF_6$ gas. A model GIS chamber was designed and manufactured. The partial discharge and breakdown phenomena due to the particles between electrodes were observed and partial discharge signals were detected, using an ultrasonic sensor. The analysis of the electric field by the states of the particle inserted between the electrodes, were also carried out. The partial discharge was observed at end while the particle was moving in $SF_6$ gas. The partial discharge in micro-gap grows to arc, and after all, it can cause a breakdown.The electric field strength was the highest in case that the particle was vertically attached on the conductor, and the lowest in case that it was horizontally attached on the enclosure.

  • PDF