• Title/Summary/Keyword: Enclosed Space

Search Result 154, Processing Time 0.033 seconds

Gas Leakage Condition and CFD analysis on Gas Fuelled ship FGS system (Gas Fuelled Ship FGS 시스템에 대한 가스누출 조건 검토 및 CFD 해석)

  • Kim, Ki-Pyoung;Kang, Ho-Keun;Park, Jae-Hong;Choung, Choung-Ho
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.7-10
    • /
    • 2011
  • According to the requirement of Res.MSC.285(86) for natural gas-fueled engine installations in ships, pump and compressor rooms should be fitted with effective mechanical ventilation system of the under pressure type, providing a ventilation capacity of at least 30 air changes per hour. It generally considered that gas leakage is more likely from a Fueled Gas Supply System(FGS) room as compared to other places, where installed in many kind of machinery or equipments like gas supply high-pressure pipes, valves, flanges and etc. Furthermore, leaked gas may be dispersed in a short time in an enclosed space, especially a FGS room, due to high pressure. However, the present requirement in Res.MSC.285(86) just considers the ventilating capacity of air changes per hour but the capacity of leaked gas. Hence, the current requirements may not meet effectively when enforcing the new propulsion systems as marine fuel. This study is conducted for the purpose of safety evaluation about the dispersion and ventilation efficiency with estimated leakage scenario. Numerical analysis predictions as the result of this paper are explained to know the features of flow pattern and the diffusion of natural gas concentration.

  • PDF

Air Pumps for Polymer Electrolyte Membrane Fuel Cells (휴대용 고분자전해질막 연료전지의 산화제 공급을 위한 전기침투 현상 기반의 공기펌프의 개발)

  • Kwon, Kil-Sung;Kim, Dae-Joong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.7
    • /
    • pp.715-720
    • /
    • 2010
  • We propose an electroosmosis-based air delivery scheme for polymer electrolyte fuel cells and experimentally investigate its feasibility. An electroosmotic pump under a low-frequency AC electric field is used to displace initially a volume of pump working liquids. This working liquid is then pumped into a space enclosed by a flexible membrane and the movement of the membrane delivers air to a fuel cell. We successfully demonstrated the operation of a forced-convection fuel cell using this technique. In this preliminary study, however, the power consumption of the pump exceeds the power generated by the fuel cell. We conclude this paper with a discussion of several ways to reduce the pump-to-fuel cell power ratio.

Numerical Study on Ventilation Method for Temperature Control of HRSG Building (HRSG건물 온도제어를 위한 환기방안에 관한 수치적 연구)

  • Kim, Chul Hwan;Lee, Jong Wook;Choi, Hoon Ki;Yoo, Geun Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.240-249
    • /
    • 2009
  • HRSG(Heat Recovery Steam Generator) building is large enclosed structure included various heat sources. This building needs to appropriately keep internal air temperature for worker's safety and operability of control devices. In this study, ventilation analysis is performed to find proper ventilation method for temperature control. Ventilation analysis is applied to entire internal space of the building with standard $k-{\varepsilon}$ model and enhanced wall treatment because of large size of the structure. And the ventilation method is considered natural and forced convection with two louver structures which has damper or not. Louver structure affect directly air circulation in near HRSG and lower region of the building. Forced ventilation provides strong inertial force which cause upward airflow. From the analysis, it is found that design requirement for internal air temperature can be satisfied by forced ventilation method with louver structure without damper.

Flame Extinguishing Concentrations and Flue Gas Compositions of n-Heptane by Mixed Inert Gas Agents (불활성 가스계 혼합소화약제의 n-Heptane 불꽃소화농도 및 배가스 조성)

  • 김재덕;김영래;홍승태;이성철
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.77-83
    • /
    • 2002
  • We measured flame extinguishing concentration and flue gas composition in the n-heptane fuel cup-burner system using inert gas agents such as nitrogen, argon, carbon dioxide and their mixtures. The flame extinguishing concentration of binary gaseous mixture was well predicted by model which contains the flame extinguishing concentration and composition of pure components. The higher average specific gravity of the mixed inert gas agents, the more excellent flame extinguishing performance. And the structure of enclosed space also affects the fire extinguishing. The composition of carbon dioxide in the flue gas was decreased with increasing extinguishing agent used. Nitrogen monoxide production is not related with increasing nitrogen, but increased at rapid mass flow rate of air in the cup-burner.

Smart Home Safety Platform Program for City Gas Leakage (도시가스 누출에 따른 스마트 홈 안전 플랫폼 프로그램 구축)

  • Ji, HyunMin;Lee, Ugwiyeon;Oh, Jeongseok
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.97-102
    • /
    • 2019
  • In this study, city gas is the most commonly used in homes, and gas accidents are increasing as demand increases. Among them, accidents due to user carelessness are the most and we try to provide information by establishing scenarios to effectively prevent this. The gas leak in the home is an enclosed space, and the appropriate Gaussian model is applied. As smart home control technology is developed by the 4th industrial revolution, it will make a foundation to provide information through program to predict and prevent gas leakage accidents and apply it to smart home safety platform.

Numerical Analysis of Optimum Air-Layer Thickness in a Double Glazing Window (이중창 공기층의 최적두께에 관한 수치해석)

  • Hwang Ho June;Choi Hyoung Gwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.191-199
    • /
    • 2005
  • Double pane window system, in which an air layer with a finite width is filled between glasses, is used in order to increase the insulation efficiency. In the present study, a conjugate heat transfer problem of a double pane window system has been studied numerically in order to investigate the effect of an air layer on the heat transmittance of the double pane window system using a finite element method based on P2P1 basis function. In this study on the conjugate heat transfer of a double pane window system, numerically predicted Nusselt numbers with or without conjugate heat transfer effect have been compared with an available existing empirical formula. It has been found that a Nusselt number from an existing formula for an enclosed space is different from that obtained from the present conjugate heat transfer analysis mainly due to the effects of a very high aspect ratio and conjugate heat transfer mechanism. Furthermore, it has been shown that the numerically estimated optimal air thickness of the double pane window system with conjugate heat transfer effect is a little bit longer than that obtained without considering conjugate heat transfer effect.

Numerical Analysis of Convective Heat and Mass Transfer around Human Body under Strong Wind

  • Li, Cong;Ito, Kazuhide
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.2
    • /
    • pp.107-116
    • /
    • 2012
  • The overarching objective of this study is to predict the convective heat transfer around a human body under forced strong airflow conditions assuming a strong wind blowing through high-rise buildings or an air shower system in an enclosed space. In this study, computational fluid dynamics (CFD) analyses of the flow field and temperature distributions around a human body were carried out to estimate the convective heat transfer coefficient for a whole human body assuming adult male geometry under forced convective airflow conditions between 15 m/s and 25 m/s. A total of 45 CFD analyses were analyzed with boundary conditions that included differences in the air velocity, wind direction and turbulence intensity. In the case of approach air velocity $U_{in}=25m/s$ and turbulent intensity TI = 10%, average convective heat transfer coefficient was estimated at approximately $100W/m^2/K$ for the whole body, and strong dependence on air velocity and turbulence intensity was confirmed. Finally, the formula for the mean convective heat transfer coefficient as a function of approaching average velocity and turbulence intensity was approximated by using the concept of equivalent steady wind speed ($U_{eq}$).

Analysis of fire hazard of karaoke utilizing the fire simulation (화재시뮬레이션을 활용한 노래방 화재 위험성 분석)

  • Kim, Tae Kwon;Park, Jong Choel
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2533-2538
    • /
    • 2014
  • In this study, 2-zone model CFAST software was used to predict the fire hazard of karaoke. Model is a three-dimensional unsteady state. Accuracy of CFAST is verified by comparing result of CFAST analysis with result of real fire experiment. For analysis results, the oxygen concentration were reduced to 10% within 5 minutes in room 5, the carbon dioxide concentration were increased to 5%. Therefore, at the enclosed space like karaoke, we can predict that dangerous situation would occur and people be suffocated because of toxic gas.

A New Sound Reception System using a Symmetrical Microphone Array and its Numerical Simulation

  • Choi Jae-Woong;Kim Ki-Jung
    • Journal of Ship and Ocean Technology
    • /
    • v.8 no.3
    • /
    • pp.18-25
    • /
    • 2004
  • Sound reception system is required to detect the sound and the quadrantal direction of the other ship's horn sound, to overcome the effects of enclosed wall for navigation space, functioning as a sound barrier. However, the realized systems can only provide quadrantal information of the other ship. This paper presents a new arrangement of microphones, having geometrically symmetric deployment with the same distances between sensors and the same angles between adjacent sensors with respect to the geometrical center. The sound pressures received at microphones are transformed into the related envelope signals by applying Hilbert transform. The time delays between microphones are estimated by the correlation functions between the derived envelope signals. This envelope base processing mitigates the noises related to the reflection by ship and sea surface. Then, the directional information is easily defined by using the estimated time delays. The suggested method is verified by the generated signals using boundary element method for a small ship model with sea surface wave. The estimated direction is quite similar to the true one and therefore the proposed approach can be used as an efficient sound reception system.

Performance Analysis on a Heat Pump System using Waste Heat (폐열이용 열펌프시스템의 성능에 관한 연구)

  • Park, Youn Cheol;Song, Lei;Ko, Gwang Soo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.53-60
    • /
    • 2018
  • This study was conducted for analysis of a heat pump system using waste heat in an enclosed space such as a green house. The model was developed with mathematical equations in literature and Engineering Equation Solver (EES) was used to get the solution of the developed equations. The simulation results have 5% of reliability comparing the results with actual test data of heat pump system's dynamic operation. The operating performance of the system was calculated with variation of working fluid temperature in the thermal storage tank such as $25^{\circ}C$, $35^{\circ}C$, $45^{\circ}C$ and $55^{\circ}C$. As a result, the system's the highest total heating capacity shows 280 kWh and the storage tank's operating time decreased as the starting storage tank's temperature was high.