Abstract
In this study, 2-zone model CFAST software was used to predict the fire hazard of karaoke. Model is a three-dimensional unsteady state. Accuracy of CFAST is verified by comparing result of CFAST analysis with result of real fire experiment. For analysis results, the oxygen concentration were reduced to 10% within 5 minutes in room 5, the carbon dioxide concentration were increased to 5%. Therefore, at the enclosed space like karaoke, we can predict that dangerous situation would occur and people be suffocated because of toxic gas.