DOI QR코드

DOI QR Code

Analysis of fire hazard of karaoke utilizing the fire simulation

화재시뮬레이션을 활용한 노래방 화재 위험성 분석

  • Kim, Tae Kwon (Department of Mechanical and Automotive Engineering, Keimyung University) ;
  • Park, Jong Choel (Department of Mechanical Engineering, Graduate School, Keimyung University)
  • 김태권 (계명대학교 기계자동차공학과) ;
  • 박종철 (계명대학교 대학원 기계공학과)
  • Received : 2014.01.16
  • Accepted : 2014.05.08
  • Published : 2014.05.31

Abstract

In this study, 2-zone model CFAST software was used to predict the fire hazard of karaoke. Model is a three-dimensional unsteady state. Accuracy of CFAST is verified by comparing result of CFAST analysis with result of real fire experiment. For analysis results, the oxygen concentration were reduced to 10% within 5 minutes in room 5, the carbon dioxide concentration were increased to 5%. Therefore, at the enclosed space like karaoke, we can predict that dangerous situation would occur and people be suffocated because of toxic gas.

본 연구에서는 노래방 화재의 위험성을 예측하기 위하여 2-zone model CFAST소프트웨어를 이용하여 해석을 수행하였다. 모델은 3차원 비정상 상태이다. 또한, CFAST의 해석 결과와 실제 화재 재현 실험결과를 비교 분석하여 CFAST의 정확성이 검증되었다. 해석 결과 화재가 발생된 방에서 화재발생 5분 이내에 산소농도는 10% 까지 감소하며, 이산화탄소 농도는 5%까지 증가하였다. 따라서 노래방과 같은 밀폐된 공간에서는 유독가스에 의한 질식으로 더 위험한 상황이 발생한다는 것을 예측할 수 있다.

Keywords

References

  1. Walter W. Jones, Richard D. Peacock, Glenn P. Forney, Paul A. Reneke, Kevin B. McGrattan., "Fire Simulation Practice", Donghwa, 2007.
  2. Y. H. Yoo, Y. H. Choi, O. S. Kweon, et al., "Real Scale Fire Test for the Karaoke Fire Risk Analysis", Journal of KOSHAM, Vol. 12, No.6, pp. 001-006, 2012. DOI: http://dx.doi.org/10.9798/KOSHAM.2012.12.6.001
  3. S. K. Lee, "Introduction of fire simulation", A-jin, 2008.