• Title/Summary/Keyword: Emergency evacuation

Search Result 305, Processing Time 0.026 seconds

A Study on the Effects of an Increase in the Height of Ship's Accommodation Area on Safe Evacuation in Emergency Situation (선박 거주구역의 높이가 피난안전에 미치는 영향에 대한 연구)

  • Kim, Won-Ouk;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.1
    • /
    • pp.69-73
    • /
    • 2011
  • Unlike land fires, Fires on board a ship are not likely to be extinguished by skilled human resources using a variety of fire fighting equipments, but have to be brought under control on board a ship itself despite of difficult task. There are more cases of deaths from suffocation by smoke than from an increased temperature by heat in fires on board ships, because crew fail to secure a sufficient visibility range enough to escape from the scene of a fire or to leave the ship as early as possible. On the assumption that the height of ship's accommodation area increases from 2.0m to 2.3m comparable to the height of apartments on the ground in Korea, behaviors of fire smokes between the cases of 2.0m and 2.3m heights were compared and analyzed. Based on the blue print of the existing Training Ship "Hanbada", a new blueprint with the 30 cm height adjustment was additionally created. FDS (Fire Dynamic Simulator), which was created by the NIST in the United States and is the most widely distributed simulator for fires, was used to conduct a simulation and predict results. The results of simulation on the basis of temperature of $60^{\circ}C$ showed a safe evacuation period of time at the position 10m apart from the scene of a fire to increase by 55.8 seconds, when the height of ship's accommodation area increased from 2.0m to 2.3m. The results of simulation on the basis of visibility range of 6m showed the safe evacuation periods of time at the positions 10m, 20m and 30m apart from the scene of a fire to increase by 27.1 seconds, 109.2 seconds and 73.3 seconds, respectively, as the height of ship's accommodation area increased from 2.0m to 2.3m. This means that crew can escape more safely from a scene of fires on board when the height of ship's accommodation area is increased and equal to the height of living room in a building on land.

A Study on the Development of Facility Model for Safety Training Class in School (학교 내 안전체험교실의 시설모형 개발 연구)

  • Park, Sung-Chul;Ahn, Yoo-Jeong;Song, Byung-Joon;Cho, Jin-ll
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.2
    • /
    • pp.19-33
    • /
    • 2017
  • The purpose of this study is to derive education programs for safety training class, create unit spaces and present components and methods of utilizing the spaces for the development of facilities models closely related to various policy, operation plan and facility construction projects promoted by related institutions such as the Ministry of Education, schools, architects and companies. This study is divided into five steps. First, we reviewed the literature related basic directions for safety education and facility plan, second, field survey included both field conditions such as spatial size and facility configuration and analysis of operating conditions like hours of operation and personnel. Base on literature review and field survey, it were used to analyze strengths and weaknesses of existing safety training classes, and five facility models was developed based on the Delphi method and expert participatory design. The result show that the facility models (drafts) of safety training class were developed as follows: (1)the facility model for traffic safety(pedestrian safety, vehicle safety, subway safety) (2)the facility model for first aid(emergency rescue, how to report) (3)the facility model for disaster safety(fire evacuation safety, life earthquake safety) (4)the facility model for elevator safety(elevator safety, escalator safety) (5)the facility model for drugs and violence safety (smoking drinking, sexual harassment safety, food safety) The safety training class can be composed by combining or separating each module according to affordable space size of each school.

A Study on Strengthening Consequence Management System Against CBRN Threats (CBRN 위협에 대비한 사후관리체계 강화방안)

  • Kwon, Hyuckshin;Kwak, Minsu;Kim, Kwanheon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.4
    • /
    • pp.429-435
    • /
    • 2020
  • North Korea declared itself complete with nuclear force after its sixth nuclear test in 2017. Despite efforts at home and abroad to denuclearize the Korean Peninsula, the prospects for the denuclearization are not bright. Along with political and diplomatic efforts to deter NK's WMD threats, the government is required to strengthen its consequence management capabilities against 'catastrophic situations' expected in case of emergency. Accordingly, this study was conducted to present measures to strengthen follow-up management against CBRN threats. The research model was partially supplemented and utilized by the THIRA process adopted and utilized by the U.S. Department of Homeland Security among national-level disaster management plan development models. Korea's consequence management (CM) system encompasses risk and crisis management on disaster condition. The system has been carried out in the form of a civil, government and military integrated defense operations for the purpose of curbing the spread or use of CBRNs, responding to threats, and minimizing expected damages. The preventive stage call for the incorporation of CBRN concept and CM procedures into the national management system, supplementing the integrated alarm systems, preparation of evacuation facilities, and establishment of the integrated training systems. In the preparation phase, readjustment of relevant laws and manuals, maintenance of government organizations, developing performance procedures, establishing the on-site support systems, and regular training are essential. In the response phase, normal operations of the medical support system for first aid and relief, installation and operation of facilities for decontamination, and development of regional damage assessment and control guidelines are important. In the recovery phase, development of stabilization evaluation criteria and procedures, securing and operation of resources needed for damage recovery, and strengthening of regional damage recovery capabilities linked to local defense forces, reserve forces and civil defense committees are required.

A Study on the Behavior of an Existing Tunnel and the Safety Implications on its Facilities from a New Tunnel Blasting (신설 터널 발파 시 기존 터널 거동 및 시설물 안전에 관한 연구)

  • Kim, Sung Hoon;Cho, Woncheol
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.2
    • /
    • pp.57-64
    • /
    • 2010
  • In this study, the behavior and safety of an existing tunnel and its facilities are investigated when a new tunnel adjacent to the existing tunnel is blasted. The design of the new tunnel puts priority on stability of the tunnel itself over the safety of the facilities which are installed within the existing tunnel such as jet fans. And thus, a detailed consideration on securing the safety of the existing facilities has been insufficient. An analysis on the types of traffic accidents in the last ten years shows that most incidents were due to the driver's improper response in emergency situations and unexpected obstacles. In consideration of this analysis, the safety of the facilities in the existing tunnel was secured by minimizing the charging amount for each hangfire and changing the excavation method of evacuation communication shelters to the large center hole cut blasting method to reduce blasting vibration. For a more quantitative analysis, measurement devices were installed inside the existing tunnel, at houses adjacent to the new tunnel, near jet fans in the existing tunnel. This enabled real time measurement of displacements of the existing tunnel, adjacent houses, and jet fans without interrupting traffic flow. Therefore, the improvements of charging amount for each hangfire, the blasting method, and the measurement method are suggested in this paper to secure the safety of the facilities in the existing tunnel when a new tunnel, located on a large city and adjacent to an existing tunnel, is designed.

  • PDF

A Study on Countermeasures between Central and Local Governments for Earthquake Disaster Management of Pohang, Korea (우리나라 포항지진 재난관리에 대한 중앙·지방정부 간 대책 방안 연구)

  • La, Hong Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.3
    • /
    • pp.25-34
    • /
    • 2019
  • Modern disasters prevent accidents in advance and recover after accidents are very important. Our government's current response to these accidents is not appropriate. As for disaster management so far, it has been the center of disaster response and recovery efforts, and has been led by the government against it. The reality is that most private organizations and agencies have only subsidized government disaster management agencies. Korea is no longer a safe zone for earthquakes. Now for the establishment of effective disaster management system for earthquakes in the diagnosis is very urgent and the problems of the operational disaster management, which the problems of the nation.Policies to improve academic efforts to seek alternative proposal is also at a time when volume can be said to be very big need to mine. This study from 2016 to 2019, about the earthquake that took place between National Statistical Office, based on analysis of data to. First of all, research 1: What was the government's plan on Pohang earthquake? The results showed that the residents' evacuation of Pohang was important in the Pohang earthquake, but for the sake of students' safety, they were directly assigned to the test site to cope with the emergency situation. Therefore, the research and analysis shows that the nation should continue to think about the causes and responses of the damage at the disaster site and strive to develop technologies and methods to minimize the damage.

Review on Prior Evaluation for Terrorism Risk of High-rise Buildings (초고층건축물의 테러 위험도 사전평가에 관한 연구)

  • Seong, Bin;Lee, Yoon-Ho
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.293-316
    • /
    • 2013
  • Today's high-rise buildings are increasing concern about the safety and evacuation of people related to the fire and threat from outside. Terrorism breaking out in high-rise buildings, a symbol of the national economy results in a number of casualties, economic loss, social fear and damage to national status. That's why high-rise building has also emerged as a target of major terrorist attacks, compared to other types of buildings. We have 54 high-rise buildings in 15 regions over the country. The Ministry of Land, Infrastructure and Transport and Seoul Metropolitan Government have offered the guidelines to prevent terrorist attacks toward high-rise buildings. Since the 9/11 terrorist attacks, the U.S. Federal Emergency Management Agency (FEMA) has developed and taken advantage of the Risk Management Manual Series. According to this manual, pre-assessment is conducted for the prevention of terrorism and particularly in FEMA 455, risk of the surrounding areas, vulnerability, possibility from terrorist attacks are checked. After the check, experts classify the risk of terrorist attacks toward the high-rise buildings and according to the risk classification, architects, security experts and structure engineers can carry out terrorism prevention program for high-rise buildings. The U.K. NaCTSO has also offered the terrorism prevention guidelines. Therefore, the Ministry of Land, Infrastructure and Transport and Seoul Metropolitan Government should make more concrete guidelines for high-rise buildings such as what U.S. FEMA and U.K. NaCTSO implement, including prior evaluation technique for terrorism risk.

  • PDF

An analysis study for reasonable installation of tunnel fire safety facility (터널 방재설비의 합리적 설치를 위한 분석적 연구)

  • Park, Jin-Ouk;Yoo, Yong-Ho;Park, Byoung-Jik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.243-248
    • /
    • 2015
  • Domestic road and railroad construction have been increasingly growing and for reasons of mitigating traffic congestion, urban plan and refurbishment project, deeper and longer tunnels have been built. The event of fire is the most fatal accident in a tunnel, and it can be very disastrous with a high possibility. In this study, QRA (Quantitative Risk Analysis) which is one of quantitative risk analysis approaches was applied to tunnel fire safety design and the evaluation of QRA cases and the cost comparison of QRA methods were carried out. In addition analysis of risk reduction effect of tunnel fire safety system was conducted using AHP (Analytic Hierarchy Process) and the priority of major factors that could mitigate the risk in tunnel fire was presented. As a result, significant cost reduction effect could be obtained by incorporating QRA and it is expected to design fire safety system rationally. The priority of fire safety system based on risk mitigation effect by fire safety system considering the cost is in order of water pipe, emergency lighting, evacuation passage and smoke control system.

A study on the case analysis of Nitric acid chemical accident and establishment of preventive measures (질산 화학사고 사례분석 및 독성피해 영향범위에 대한 연구)

  • Lee, Hyun-Seung;Shin, Chang-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.488-496
    • /
    • 2020
  • This study was based on nitrate chemical accidents at home and abroad. Toxic gases due to adverse reactions are generated in the workplace, laboratory, hospital, container damage, and chemical misinjection. Through a case review of possible situations and safety, this study analyzed various cases of accidents, accident status, accident type, cause of the accident, location of the accidents, etc. from 2014 to 2018. The plans for improvement in education and nitrate accidents were reviewed. As a result, 36 nitrate chemical accidents were investigated, including 16 careless worker accidents, eight transportation accidents, and 12 facilities shortages. Nitrate chemical accidents are occurring continuously. Based on this, the range of toxic effects using CARIS was calculated at the worst-case scenario, and the effective response range was measured through the damage impact range. For this purpose, the impact range was predicted based on the strengthening of safety education, emergency action plan and correlation, and the quantified data was identified. In addition, the reliability of the scope of impact was reviewed based on the correlation formula that could facilitate the evacuation of residents, and it was applied to actual accident scenarios of the workplace to present the effects of the accident response and preventive measures.

Legal Interpretation on Management Power of Article 7 Section 1 of Security Business Act (경비업법 제7조 제1항 "관리권 범위"에 대한 법적 해석)

  • Lee, Jong-Hwan;Lee, Min-Hyung
    • Korean Security Journal
    • /
    • no.26
    • /
    • pp.59-87
    • /
    • 2011
  • Security Business Act of Korea is leaning toward the aspect of regulation, while it provides few provisions about vesting the authority, which causes problems such as legal loopholes to be raised in regard to the rules about authorizing the private security personnel to perform security affairs properly and defining the limit of power. So, it should be done to interpret the law in order to draw the legal basis of empowering as well as to set limits of the authority of security main agent, and Article 7, Section 1, of Security Business Act is the very provision that involves the legal basis. In the scope of 'Management Power', the statutory authority in the first clause of Article 7 of Security Business Act, the security personnel can use force for self-defense, defense of others and property, and prevention of crimes. In addition, the powers of interrogation, access control, and eviction notice are involved in its scope. The private security personnel as the occupation assistant can take precautions and if the infringement on the benefit and protection of the law is imminent or done, he or she can use force within the limits of the passive resistance and the means of defiance on the basis of 'Management Power'. The private security personnel, however, can exercise the force only if the necessary conditions of legal defense, emergency evacuation, and legitimate act of criminal law are fulfilled.

  • PDF

Analysis of Shelter Service Areas According to Walking Speed Using Network Analysis (네트워크 분석을 이용한 보행속도에 따른 대피소 서비스 영역 분석)

  • Park, Jae Kook;Kim, Dong Moon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.4
    • /
    • pp.37-44
    • /
    • 2012
  • There are approximately 25,724 shelters to which people can be quickly evacuated for safety in case of emergency across the nation, and Seoul has about 3,870 shelters. Those nationwide shelters are located at a point within a five-minute radius for quick evacuation. Seoul's shelter capacity can hold 285% of its population. The problem is, however, that there is no knowing how many shelters are reachable within five minutes when considering walking speed according to individual differences in age, height, health state, and physical condition. In addition, available service areas become different according to the spatial allocation and distribution of shelters with possible vulnerable points. This study thus defined the pedestrian walking speed at 1m/s, 1.3m/s, and 2m/s by reviewing previous studies and conducted network analysis of the Location Allocation Model with the designated shelters and road networks in Seoul. The results identified the shelter service and vulnerable areas in each administrative district of Seoul according to walking speeds. It was analyzed that the vulnerable areas in which the elderly could not reach a shelter were more than twice as big as those of adult men and women with a fast walking speed.