• Title/Summary/Keyword: Emergency Stop

Search Result 110, Processing Time 0.028 seconds

Waterhammer Caused by Startup and Stoppage of a Centrifugal Pump (원심펌프의 시동 및 정지에 따른 수격현상)

  • Kim, Kyung-Yup;Kim, Joum-Bea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.1 s.22
    • /
    • pp.51-57
    • /
    • 2004
  • The waterhammer has recently become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. When the pumps are started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity As the pressure waves are propagating between the pumping station and the distributing reservoir, the pressure inside the pipe drops to the liquid vapor pressure with the pipeline profile, at which time a vapor cavity forms, and finally the column separation occurs. If the pressure in the pipe is less than the atmospheric pressure, the pipe can be collapsed and destroyed after the water columns separated by the vapor cavity rejoin. During the reverse flow, the pressure is so abnormally increased at the pumping station that the accident of flooding may happen due to the failure of system. In this paper, the field tests on the waterhammer by the startup, stoppage, and power failure of a centrifugal pump were carried out for Yongma transmission pumping station in Seoul. The experimental results were compared with that of the numerical calculations, in which results the procedure of controlled pump normal shut-down and the two-step closing mode of controlling the ball valve for pump emergency stop are proposed to reduce the pressure surge.

A Study on the Multi-Joint Rehabilitation System of an Industrial Robot

  • Lee, Yong-Seok;Jang, Jae-Ho;Sim, Hyung-Joon;Han, Chang-Soo;Han, Jung-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.92-95
    • /
    • 2004
  • This study proposes an industrial rehabilitation robot system which can exercise two joints in 3 dimensional spaces. The robot kinematics analysis and the results of studies on each joint for the rehabilitation robot could verify possibility of rehabilitation motion to exercise a joint. The force and torques sensor not only measures a rehabilitation performance of subjects between the abnormal limb and the manipulator, but also carries out an important function of safety device to prevent accidents. Also, limit sensors and emergency stop switch are used for high safety in this system. In this real test, the possibility of rehabilitation robot system is evaluated by C&R ARM I which is similar to upper-limb.

  • PDF

Simulation Technique of Wind Turbine Dynamic Behavior using Multibody FEM Analysis (탄성 다물체 동역학 해석기법을 이용한 풍력터빈 드라이브트레인의 동특성 해석)

  • Lee, Seung-Kyu;Lim, Dong-Su;Park, Young-Su;Kim, Jin;Choi, Won-Ho
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.817-821
    • /
    • 2008
  • Wind turbine requires service life of about 20 years and each components of wind turbine requires high durability, because installation and maintenance costs are more expensive than generated electricity by wind turbine. So the design of wind turbine must be verified in various condition before production step. This paper demonstrates the application of a generic methodology, based on the flexible multibody simulation technique, for the dynamic analysis of a wind turbine and its drive train. The concern of the paper is the computation of dynamic loads of wind turbine in emergency-stop condition. The finite element model is used to analyse the dynamic behaviour of the wind turbine.

  • PDF

Reduction Plan for nip accidents by a Roller Machine (산업용 로울러기의 협착재해 감소방안)

  • 박재범;강동규;김두현
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2003
  • The roller machines installed in the industrial field are operated under hazardous conditions due to no safety devices available, human error during operation, defective safety devices, and inadequate regulation even in case that safety devices are provided. Up to now, most roller machines installed in domestic field are provides with band breaking system as a safety device. In this study, the emergency stop distance is measured within the limit of domestic regulation but violates a foreign regulation(EN1417). Consequently, it is concluded that the roller machines with a band breaking system have high possibility of death or serious injury of the operator and the system should be improved with the introduction of additional safety devices. This thesis suggests the safety measures suitable for the roller machines with different drive systems based on the experiment results. The use of the newly developed safety system has been tested on many cases.

Research about Operation Status of Safety System in High speed Rolling-stock (고속철도차량 안전장치의 운영 실태 조사)

  • Ryu, Byung-Gwan
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1178-1187
    • /
    • 2008
  • According to the operation data between $2007{\sim}2008$(January$\sim$June) for essential safety equipment including ATC, there were nothing special but stable and steady. And also emergency stop number of count are decreasing. But the frequency are still above the resonable count and it means driving condition should be improved through interface between ground and locomotive same as come to an understanding with driver. The number of count of emergency stop for VACMA(vigilance system) are also decreasing but also the frequency are above resonable count. This phenomenon caused by careless driving for the driver or the system malfunction. So the continuous monitoring for the data is necessary.

  • PDF

A Study on Design and Algorithm of Emergency Lamp Controller for the Alarm Security (도난 경계 경보기용 비상등 컨트롤러의 설계 및 알고리즘에 관한 연구)

  • 윤석암;박종복;윤형상;최장균;차인수;김원배;조명현
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.43-47
    • /
    • 1998
  • In this paper we present the method that improve alarm security system using the electronic circuits added the emergency lamp by our proposed Algorithms. In conventional method the emergency lamp of warning & alarm system was not executed perfectly its performance because of battery with short life. For improving this problem we, using Peripheral Interface Controller IC, designed the circuit added the emergency lamp for an warning & alarm system and for prevent from stopping the electric current, and compared our proposed method with conventional method. By designing the circuit to stop up over charge we can extend life of battery, use of a stoppage of electric current in emergency and according to the lightness around. Therefore we are very convenient and profitable in our life. In this future we will study the method to lower the cost of architecture for practical utilization.

  • PDF

Waterhammer for the In-Line Intake Pumping Station with Air Chamber (에어챔버가 설치된 인라인 취수펌프장에서 수격현상)

  • Kim, Kyung-Yup;Ahn, Cheoul-Hong;Kim, Bum-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.70-76
    • /
    • 2012
  • Recently, because people are taking a great interest in the water supply system and the related facilities are getting larger, the surge suppression is very important problem. The waterhammer occurs when the pumps are started or stoped for operation or tripped due to the power failure. As the waterhammer problems as a result of the pump power failure were very serious, these situations were carefully investigated. Accordingly, we carried out both numerical simulations and field tests to confirm the safety of Juam intake pumping station in which had the in-line pumps. In this paper, it was reviewed that the water supply system has the reliability on the pressure surge, in case the air chambers were installed at both the inlet and the oulet of the in-line pumping station. From the numerical simulations, we found that negative pressure occurred at the inlet disappeared and high pressure occurred at the outlet reduced due to the air chambers. And these results of numerical simulations verified by the field tests. The field tests carried out in case of normal start, normal stop, one and two of pumps emergency stop. By results of simulations and field tests, we are sure that Juam intake pumping station in which have the air chambers is safe for the waterhammer. In addition, we suggested the operation methods of facilities for safe maintenance of the pumping station.

A Study on the In-Pipe Surge Analysis for Cargo Unloading Piping System of LNG Carrier (LNG선의 화물 하역 배관망의 과도 응답 해석에 관한 연구)

  • Chun, Byung-Il;Woo, Jong-Sik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.124-134
    • /
    • 1996
  • In this paper the pressures and flowrate distributions in the loading/unloading piping system of LNG carrier have been investigated in the case of unsteady flow state as well as steady one. Under emergency situation the main cargo pumps are forced to fail, and the ESD(Emergency Shut Down) valves and Stop valves are closed within set-time. The surge pressures according to the variations of valve closing time have been computed to recognize the surge phenomenon due to sudden decrease of flowrate. By means of these analysis results, the most important factors on the in-pipe surge phenomenon of cargo loading/unloading piping system of LNG Carrier are the type of ESD and Stop valves, valve closing time, and the pipe arrangements.

  • PDF

Analysis of the Electromagnetic Clutch for Emergency Power Generator (비상발전기용 전자클러치의 자계해석)

  • Jeon, Mun-Ho;Kim, Chang-Eob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.111-116
    • /
    • 2011
  • This paper deals with the electromagnetic clutch which stop the generator at emergency by using the engine power of generator. The electromagnetic field was analyzed using Flux-2d program with different conditions : voltage, air gap, coil locations. As a result, the maximum magnetic flux density of electromagnetic clutch occurred between the coil and wheel : 0.27[T], 0.41[T] at 12[V], 24[V]. The maximum flux density was at the center location of the coil.

A Study on Three Parallel Operation Control Algorithm of Thyristor Dual Converter System for Urban Railway Substation (도시 철도용 사이리스터 듀얼 컨버터 시스템의 3병렬 운전 제어 기법에 관한 연구)

  • Kim, Sung-An;Han, Sung-Woo;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.459-467
    • /
    • 2017
  • An urban railway power substation consists of three thyristor dual converters. Two converters are connected to up and down trolley line to supply the electric energy or feed the regenerative energy back to the distribution. When the two converters break down, the remaining converter is used in an emergency. One thyristor dual converter system (TDCS) manages the energy of two or three railway stations. If the TDCS fails, the trains stop operating. To solve the problem, this paper proposes the three parallel operation control algorithm of thyristor dual converter system using the emergency converter. The broken TDCS can be replaced by the emergency converter in other TDCS. The effectiveness of this proposed control is verified by simulation.