• 제목/요약/키워드: Emergency Generator

검색결과 198건 처리시간 0.03초

비상발전기용량 산정식 개선에 관한 연구 (A Study on the Improvement of the Arithmetic for Emergency Generator Capacity)

  • 이종혁;김진오
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1517-1522
    • /
    • 2018
  • This paper describes the improvement of the arithmetic for emergency generator capacity. This formula which calculates emergency generator is dependent on the Korean Design Standard of building electrical equipment issued by the Ministry of Land, Infrastructure and Transport, and the technical data related to the generator. when appling the formula, the capacity of the generator is insufficient at the starting conditions of the load facility. In case of emergency, the generator is not operated normally. $PG_2$ of the formula ($PG_1$, $PG_2$, $PG_3$) applied in determining the capacity of the emergency generator is selected by calculating the capacity of the generator based on only biggest one motor among the load equipment and $PG_3$ may not be able to start the generator normally in case of emergency because there is an error such that the power factor is applied at the last start of the motor having the maximum capacity of the load. We analyze the problem of capacity calculation of emergency generators used for general purposes. As a consequence, the improved formulas have been presented for safety of electrical installation.

원자력발전소 비상디젤발전기 상태감시를 위한 운전인자 선정에 관한 연구 (Selection and Analysis of Operating Parameters for Condition Monitoring of Emergency Diesel Generator at Nuclear Power Plant)

  • 박종혁;최광희;이상국;박종은
    • 동력기계공학회지
    • /
    • 제11권3호
    • /
    • pp.3-8
    • /
    • 2007
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear reactor at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the plant safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to maintain and monitor and forecast the reliability level of diesel generator. To do this kind of diesel generator condition monitoring we reviewed several operating factors and history of the wolsong unit 3 diesel generator and selected the proper conditioning monitoring operating factors.

  • PDF

원자력발전소 비상디젤발전기 상태감시 기술 적용 연구 (Application Study of Condition Monitoring Technology for Emergency Diesel Generator at Nuclear Power Plant)

  • 최광희;박종혁;박종은;이상국
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.53-58
    • /
    • 2009
  • The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

  • PDF

비상용 디젤발전기 제어시스템 설계 (Design of a Control System for the Emergency Diesel Generator)

  • 김진애;주재훈;백판근;김병준;최중경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.849-853
    • /
    • 2009
  • 발전기는 차량용에서부터 항공, 선박용등 이동 장치에서 사용될 뿐만 아니라, 화력, 수력, 원자력 발전소 등 기간 산업에서도 사용되고 있다. 이러한 교류 발전기는 차량이나 선박, 항공기 등에서 전기를 생산하는 아주 중요한 역할을 한다. 특히, 선박에서는 항해 중 발생할 수 있는 발전기 고장에 대비하여 비상용 발전 시스템을 장착하고 있다. 따라서 발전기 시스템을 항상 모니터링하여 발전기 이상 발생 시 비상 발전기를 가동할 수 있어야 한다. 본 연구는 비상용 디젤 엔진 발전기를 위한 제어기 및 각종 소프트웨어 설계에 관한 연구이다.

  • PDF

화학 플랜트에서의 비상발전기 용량선정 방안(PG3)에 관한 연구 (Study on Emergency Generator Capacity Selection(PG3) in the Chemical Plant)

  • 이승재;조만영;김세용;김은태;강병욱;박한민;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.55-60
    • /
    • 2015
  • PG and RG methods are widely known method for calculating the capacity of the emergency generator in construction electrical installation. PG and RG methods are mainly used as a saving a life, fire protection, fire fighting in construction. Because no long distance between the emergency generator and electric motor feeder, the relatively small motor power in construction electrical installation, the capacity of generator in PG and RG methods are little problem of voltage and reactive power of generator. However in many cases the application of the PG and RG method is difficult in the Chemical Plant because it is long distance between the generator and the motor Feeder and motor capacity is very large. Motor starting power factor is about 0.2 lagging power factor and motor starting current is about 6times during motor staring. Also Most of the staring current component is a reactive power component. therefore, it is many cases that lack of reactive power and excess of allowable voltage drop limit and After selection of emergency diesel generator, problems happen during motor starting. Therefore, to be selection of effective emergency generator, active generator power, reactive power and the required reactive power during large motor starting should be considered in chemical plant. It is also required of the verification process through simulation because hand calculation is very difficult considering study cases.

비상발전기 설치 실태조사 및 활용 방안에 대한 고찰 (A Study on Current Status Survey and Utilization of Emergency Generator Installation)

  • 임현성;한운기;정진수;박찬엄;송영상;최종수
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.34-38
    • /
    • 2015
  • Recently, the power supply situation has deteriorated and the plan has issued to utilize of emergency generators for securing standby power. If a part of Emergency Generators was utilized by peak shaving, it can be avoiding over-investment in supply power facility. In this paper we investigate management of Emergency Generator and understand the current situation. So, we verify demand response resource possibility of Emergency Generator.

대용량유도전동기 기동시의 비상용 디젤발전기 동특성 해석 (Dynamic Analysis of Diesel Generators on Starting Large Induction Motors)

  • 한풍;조성돈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.139-142
    • /
    • 1987
  • It is important to evaluate the voltage characteristics of diesel generator as an emergency power supply in nuclear power plant. On loss of offsite power sources, emergency safeguard loads required to safely shutdown the reactor should be supplied by diesel generator. This paper presents the dynamic stability program to evaluate diesel generator performance as an emergency power system. The results Indicate the diesel generator ability to start the motors successfully seems to life in its impedances and inertias.

  • PDF

비상발전기 보호용 원판형 지락과전류계전기의 고조파영향에 관한 연구 (A Study on the Harmonics Effect of Disc-Type Over Current Ground Relay for Emergency Generator Protection)

  • 김경철;고훈
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.58-62
    • /
    • 2015
  • When an emergency generator is running, it supplies the power for critical loads. Generator protection requires the consideration of many abnormal conditions that may occur with generators include overvoltages and ground faults. Modern day power systems create harmonics within the electrical network that can have an impact upon the associated protective system. This paper focuses on the analysing of the cause and development of a solution for the malfunction of induction disc type overcurrent ground relay by generation of harmonics during emergency generator operation.

비상디젤발전기 엔진 상태진단 초음파 탐촉자 개발 (Development of Ultrasonic Sensor for Engine Condition Diagnosis of EDG)

  • 이상국;최광희
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.31-35
    • /
    • 2013
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear power plant at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite standby diesel generator should be ensured by a condition monitoring system designed to maintain, monitor and forecast the reliability level of diesel generator. The purpose of this paper is to improve the existing ultrasonic sensor used for condition diagnosis of engine fuel pump and cylinder head for the accurate diagnosis in actual engine condition of emergency diesel generator(EDG). As a result of this study, we could design and develop much more reliable ultrasonic sensor than existing ones.

항공기 승객용 화학적 비상산소 공급 및 조명시스템에 대한 연구 (Research for the Chemical Emergency Oxygen Supply and Lighting System for Aircraft Passengers)

  • 김영인
    • 한국항공운항학회지
    • /
    • 제30권2호
    • /
    • pp.55-60
    • /
    • 2022
  • A PSU (passenger service unit) is mounted on passenger seats in a cabin on an aircraft and consists of a crew call lamp, a reading lights, an information display lamp, an emergency oxygen generator, and an emergency oxygen mask. It is a safety device for providing convenience to passengers and providing oxygen to passengers in an emergency. This paper is a study on emergency oxygen supply systems and light systems of aircraft PSUs and a control device was developed to operate the system by analyzing the B767-300 aircraft's PSU circuit diagram. And the temperature generated by the B777-200ER aircraft's emergency oxygen generator was also measured by operating it directly. Through this, precautions for explaining the operation of an oxygen mask in an emergency were described and improvements were presented. Data acquired in these research processes can be used in the future to develop aircraft PSU (passenger service unit) and emergency oxygen generators.