• 제목/요약/키워드: Elevator Shaft

검색결과 17건 처리시간 0.023초

엘리베이터용 사다리꼴 에어 스크류의 설계 (Design of Trapezoidal Air Screw for Elevators)

  • 박상신;김진호
    • Tribology and Lubricants
    • /
    • 제24권1호
    • /
    • pp.14-20
    • /
    • 2008
  • In this paper, the characteristics of trapezoidal air screws is studied. These screws can e applied to the elevator having column driving shaft. The generalized coordinate transformation technique is used to solve incompressible Reynolds' equation because the air lubricated plane is twisted. The transformed equation is discretized by the base of Finite difference method. Using Visual C++ language, a GUI program which can calculate he load carrying capacity for this kind of air screw is developed, then the design variables for these air screws is studied.

건축화재시 피난대책에 관한 연구 -고층건물의 제연을 중심으로- (A Study on the Smoke Proof Measure of High Rise Buildings.)

  • 이영재;이근영
    • 한국화재소방학회논문지
    • /
    • 제4권1호
    • /
    • pp.3-12
    • /
    • 1990
  • This study is to Present the air Pressurization system of staircase as a way to decrease the injury of human life which is suffocated by smoke when the fire break out in building. 1) The best among an air pressurization system of stairshaft Is multiple air Injection system established to be situated an air injection point in each layer. 2) If the air pressurization system is also applied to the elevator accessory room to use commonly, it can prevent from the smoke spreading and pollution inside building caused by stack effect of elevator shaft. 3) For the reasonable and safe escape and air pressurization system must be carried out from the project of basic shape of building under the close cooperation with architect and fire protection expert.

  • PDF

엘리베이터 승강로의 유량계수 산정에 관한 실험 연구 (An Experimental Study on the Estimation for the Flow Coefficient of Elevator Hoistway)

  • 김학중
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.43-48
    • /
    • 2012
  • 최근 건축물이 대형화, 복잡화되면서 건축물내 거주자의 피난 안전성이 관심의 초점이 되고 있다. 초고층 건물의 경우 화재 발생 시 계단을 통한 피난에 시간이 많이 소요되고 특히, 장애인의 경우 계단을 통한 피난 자체가 불가능할 수 있다. 이에 거주자의 피난에 엘리베이터를 이용하는 방법에 대한 연구가 진행되고 있다. 본 연구에서는 엘리베이터를 피난에 이용하기 위하여 엘리베이터 승강로가 연기에 오염되지 않도록 하는 연구의 일환으로 엘리베이터 운행 시 승강로 내의 유량계수를 실험을 통하여 살펴보았다. 유량계수는 엘리베이터 피스톤 효과의 양을 결정짓는 중요한 인자이다. 본 연구의 결과는 엘리베이터 피스톤 효과에 대한 연구의 기초 데이터로 활용 가능하다. 실험은 3층과 2층 건물 5곳의 엘리베이터 승강로에서 수행하였으며, 실험 결과 평균 유량계수는 0.954이며 99.99 % 신뢰도를 위해 $4{\sigma}$를 적용하였을 경우 유량계수가 0.86으로 나타났다. 이 결과는 Klote와 Tamura가 제안한 0.83보다 3.6 %가 큰 값이며, 동일 조건의 엘리베이터 운행 시 피스톤 효과에 의한 최대 계산 압력이 약 7 % 감소함을 의미한다. 이 결과는 현재의 초고층 건물의 제연성능 평가 시 엘리베이터 피스톤 효과의 최대 임계압력을 적용할 경우 보다 실제적이고 작은 값을 적용하여 경제성을 확보할 수 있다는 것을 의미한다.

수직통로의 형상이 연돌효과에 미치는 영향에 관한 수치해석 연구 (A Numerical Study on the Influence of the Shaft Geometry on the Stack Effect)

  • 전흥균;추홍록
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.74-81
    • /
    • 2011
  • 고층건물의 수직통로 형상이 연돌효과의 차압과 중성대 위치에 미치는 영향을 알아보고, 연돌효과의 발생현상을 가시화하기 위하여 3가지 형상의 수직통로, 즉 단순 수직통로, 승강기 수직통로 및 계단실 수직통로에 대하여 CFD 모델인 FDS(ver. 5.3) 프로그램을 사용하여 수치해석 하였다. 연돌효과 초기(t = 10 s) 차압은 승강기 수직통로인 경우(79.3 Pa)가 이론식 계산 결과(78 Pa)와 잘 일치하였다. t = 300 s 시점에서 중성대 위치는 3가지 경우 모두 49 m 이상으로 이론식 결과 보다 5 m 이상 높게 나타났다. 수직통로 상부와 하부지점 사이의 최대차압은 수직통로의 구조가 복잡할수록 감소하였다. 연돌효과 가시화를 통하여 수직통로 형상에 따라 연돌효과에 차이가 있다는 것을 알 수 있었다.

복층터널 연결 수직구용 철재브래킷 구조성능 연구 (A study on structural performance of steel brackets in vertical shaft connected to double-deck tunnel)

  • 신영완;민병헌;남정봉;이상환
    • 한국터널지하공간학회 논문집
    • /
    • 제21권3호
    • /
    • pp.363-375
    • /
    • 2019
  • 복층터널은 도심지에서 대심도로 시공되는 특성이 있으므로 복층터널용 수직구는 급기 및 배기구, 대피통로 계단, 엘리베이터, 배전시설, 접속터널 등의 설치공간의 확보가 필요하다. 또한 복층터널용 수직구는 도심지에 시공되는 특성상 공사영향 최소화를 위하여 터널굴착 완료 후 수직구 내부 콘크리트 구조물의 급속시공이 필요하다. 따라서 수직구 내부 슬래브 및 계단용 콘크리트 시공의 프리캐스트화가 필요하며 이러한 수직구 내부 프리캐스트 구조물 지지를 위한 브래킷의 급속시공기술이 필요하다. 브래킷 형태 사례조사 결과 현장타설 방식, 프리캐스트 방식, 철재브래킷 방식 등이 있는데 본 연구에서는 시공속도 향상을 고려하여 경제성이 양호하고 시공성이 우수한 철재브래킷을 개선한 새로운 브래킷에 대하여, 직선형 매립 앵커볼트와 꺾임형 매립 앵커볼트에 대한 구조성능시험결과 소요하중 지지능력을 확보하는 것을 확인하였고 꺾임형 매립 앵커볼트의 하중지지능력이 보다 큰 것을 확인하였다.

건축물 계단에서의 연돌효과 저감방안에 대한 현장실험 연구 (Study on Field Experiment of Stack Effect Reduction in Stairwell of Building)

  • 김정엽;김지석;이수각
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.484-490
    • /
    • 2015
  • The winter stack effect that occurs in vertical construction passages such as the stairwell or elevator shaft of a high-rise building negatively affects living environments, energy usage, and personal safety; therefore, a mitigation of the stack effect is required to improve building conditions. Recently, circulation-type facilities that comprise the usage of air blowers and vertical ducts were proposed as part of a mechanical approach to quantitatively control the stack effect. In this study, these circulation-type facilities were installed in a building stairwell and the performance of the device was evaluated during its operation. A numerical-analysis result was obtained under the test conditions using a network-model-based, numerical-analysis method, and the result was then used for a comparison with the test result.

A vision-based system for long-distance remote monitoring of dynamic displacement: experimental verification on a supertall structure

  • Ni, Yi-Qing;Wang, You-Wu;Liao, Wei-Yang;Chen, Wei-Huan
    • Smart Structures and Systems
    • /
    • 제24권6호
    • /
    • pp.769-781
    • /
    • 2019
  • Dynamic displacement response of civil structures is an important index for in-construction and in-service structural condition assessment. However, accurately measuring the displacement of large-scale civil structures such as high-rise buildings still remains as a challenging task. In order to cope with this problem, a vision-based system with the use of industrial digital camera and image processing has been developed for long-distance, remote, and real-time monitoring of dynamic displacement of supertall structures. Instead of acquiring image signals, the proposed system traces only the coordinates of the target points, therefore enabling real-time monitoring and display of displacement responses in a relatively high sampling rate. This study addresses the in-situ experimental verification of the developed vision-based system on the Canton Tower of 600 m high. To facilitate the verification, a GPS system is used to calibrate/verify the structural displacement responses measured by the vision-based system. Meanwhile, an accelerometer deployed in the vicinity of the target point also provides frequency-domain information for comparison. Special attention has been given on understanding the influence of the surrounding light on the monitoring results. For this purpose, the experimental tests are conducted in daytime and nighttime through placing the vision-based system outside the tower (in a brilliant environment) and inside the tower (in a dark environment), respectively. The results indicate that the displacement response time histories monitored by the vision-based system not only match well with those acquired by the GPS receiver, but also have higher fidelity and are less noise-corrupted. In addition, the low-order modal frequencies of the building identified with use of the data obtained from the vision-based system are all in good agreement with those obtained from the accelerometer, the GPS receiver and an elaborate finite element model. Especially, the vision-based system placed at the bottom of the enclosed elevator shaft offers better monitoring data compared with the system placed outside the tower. Based on a wavelet filtering technique, the displacement response time histories obtained by the vision-based system are easily decomposed into two parts: a quasi-static ingredient primarily resulting from temperature variation and a dynamic component mainly caused by fluctuating wind load.