• Title/Summary/Keyword: Elevator Safety

Search Result 141, Processing Time 0.023 seconds

Behavior Analysis of Small Size Elevator Brake (소형 승강기 제동장치의 거동해석)

  • LEE, Jong-Sun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.2
    • /
    • pp.401-406
    • /
    • 2016
  • Elevator is very important transportation facility of modern society. But there have been frequent elevator accidents recently. In the view of safety management of elevator, the corresponding study must be done since accidents related elevator include not only actual accident but also possible accident in order to protect user from danger. A 3D design was developed using SolidWorks and behavior analysis using FEM Code.

The Integrated Model of CCTV, Remote Control and Direct Call for the Elevator Safety based on Information Technology (IT기반 승강기안전을 위한 CCTV, 원격제어 및 직접통화장치 통합 모델)

  • Kim, Woon-Yong;Park, Seok-Gyu
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.4
    • /
    • pp.697-702
    • /
    • 2012
  • With an elevator supply and demand increases, It has been enlarged various requirements for the safety of the elevator. Elevator safety requirements can be the ability to respond to emergencies quickly. Recently, QR code was attached to all elevator for the elevator safety and it is established by law for the Elevator rescue work. And also the elevator system is seeking to utilize more secure elevator with mandatory installation of CCTV and direct call devices. However, CCTV and direct call service is operating on an individual method and it has not been proposed integrated model. In this paper, we propose the safety elevator integration model with CCTV, direct call service and remote control based on smart phone. Using the proposed model, we can be improved the efficiency of maintenance and ability of prompt action in the event of a disaster.

The Comparative Study on Safety Factors at Elevator Management System Operation (승강기 관리시스템 운영 시 안전요소에 관한 비교연구)

  • Park, Joo-Bong;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.159-162
    • /
    • 2014
  • Recently, from 2008 to 2012, there are many of elevator safety patents from patent office survey. In this paper, we analyzed the elevator safety patent from 2009 to 2013, found out safety factor is safety control, emergency stop equipment and door opening equipment. Through reliability statistics, we defined the most important things for safety elevator factor is this three things, studied the reason about many patents. Finally, we propose the Kinect Scada elevator system for prevention safety accident.

Cause Analysis and Measure for Accident of Door Detachment in Elevator Platform (승강장 도어이탈 안전사고에 대한 원인분석 및 대책)

  • Kim, Eui-Soo;Kim, Sang-Hyeon;Kim, Dong-Hwan;Park, Nam-Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.1-6
    • /
    • 2007
  • A Recently elevator accidents were occurred and increased due to carelessness of user and violent behavior. The accident of door detachment in elevator platform by electronic motor scooter show a example of safety concerns and insensibility for safety awareness. In this report, we review the cause of accident of door detachment in elevator platform by electronic motor scooter, and show some suggestions of preventing from the safety concerns about this case.

Electric malfunction research for safety of elevator system (승강기 시스템의 안전성을 위한 전기적 오동작 조사)

  • Lee, Hee-Tae;Kim, Jae-Chul;Kim, Gi-Hyun;Bae, Suk-Myong
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.316-318
    • /
    • 2005
  • Increasing elevator system every year that is directly connected passenger's safety and connected peculiarity Reliability of each variety equipment that is composing elevator is linked with passenger's safely, and prevent accident is important. Malfunction by electric part of elevator system that is composing elevator is not easy to examine closely the cause. Estimation about malfunction of component by electric power quality must consist among them. In this paper, inspect elevator accident figure to examine effect that electric power quality gets on elevator that see and presented thing for research direction and necessity of electric safety consideration by such electric malfunction.

  • PDF

Evaluation of Escape Safety Depending on the Number of Users of Residential Convenience Facilities in the Apartment Complex and the Kind of Elevators

  • Cho, Seong-Suk;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.376-384
    • /
    • 2021
  • This study wants to provide basic data on effective escape safety plans when residents of apartment complex use residential convenience facilities. The findings of the analysis are as follows. First, when this study applied the actual number of users (No=54) of those facilities, the existence of elevator for escape reduced the escape time by 189.0 seconds. Second, when the number of users was calculated on the standard of the number of people who can be accommodated for performance based design (No=316), the existence of the elevator for escape reduced the escape time by 173.5 seconds. Finally, when the number of users was calculated on the standard of installing fire-fighting facilities (No=122), the existence of the elevator for escape reduced the escape time by 159.2 seconds. As a result, it was found that elevator for escape reduces the escape time from fire. Accordingly, it is necessary to revise the construction law to make it obligatory for residential convenience facilities to be equipped with elevator for escape. Currently, apartment buildings lower than 30 stories have either elevator for passengers or elevator for escape. Thus, in future studies, it is necessary to compare escape times in fire depending on the kinds of elevator, and identify the usefulness of elevator for escape.

An Analysis of the Relationship between Elevator Emergency(Entrapment) and Situation Measurement of Sag/Interruptions at the Switchboard

  • Kim, Gi-Hyun;Lim, Young-Bae;Bai, Seok-Myung;Kim, Jae-Chul;Lee, Hee-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.36-44
    • /
    • 2007
  • This study researched the mutual relationship between elevator emergencies(sudden stops, entrapment) and power quality such as voltage interruptions or sags. To analyze the power quality at the elevator switchboard of an apartment, the on-line power quality(sag, swell, and interruption, etc.) were measured and error messages(under voltage error, etc.) in the elevator control room were researched. Also the performance and susceptibility for stops were evaluated and stated through the testing of three pieces of simulated test equipment with an EN12016(2004) standard setting and the magnitude and duration data of the measured sag or interruption. This paper will use these data in the analysis of the mutual relationship between power quality and elevator emergencies.

Development of a Pre-prediction Model for Elevator Maintenance Quality and Evaluation of the Influence of Detailed Quality Factors Using Logistic Regression Analysis (로지스틱 회귀분석을 이용한 승강기 유지관리품질 사전예측모형 개발 및 세부 품질 인자의 영향력 평가)

  • Kyung-Min Roh;Kwan-Hee Han
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.4
    • /
    • pp.133-141
    • /
    • 2023
  • Approximately 40,000 elevators are installed every year in Korea, and they are used as a convenient means of transportation in daily life. However, the continuous increase in elevators has a social problem of increased safety accidents behind the functional aspect of convenience. There is an emerging need to induce preemptive and active elevator safety management by elevator management entities by strengthening the management of poorly managed elevators. Therefore, this study examines domestic research cases related to the evaluation items of the elevator safety quality rating system conducted in previous studies, and develops a statistical model that can examine the effect of elevator maintenance quality as a result of the safety management of the elevator management entity. We review two types: odds ratio analysis and logistic regression analysis models.

Accident Prevention for the Elevator and Escalator by the Accident Type Analysis (사고유형 분석에 의한 승강기 및 에스컬레이터 재해예방)

  • Jeong, Ok Nam;Yun, Yu Seong;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.15-21
    • /
    • 2016
  • The elevator is an essential part of the transportation means in modern society. It has become the convenient movement means of vertical and horizontal mobilities for vulnerable citizens including the disabled or elderly in skyscrapers and the multi-purposes facilities. After the 1990s, the number of newly installed elevators have increased because of the establishment of large scale public houses which need an increase of means of transportation. Thus, the safety accident in the elevator has been currently in an increasing trend as years passed by because that the elevator is always exposed to the risk of accident. Most of the elevator accidents occur in the escalator and moving walkway. This study investigated the current usage situations of users at multi-purpose shopping spaces, the sub way, and the airport about the escalator including moving walkway. Moreover the accident types were analyzed for the escalator based on 10 years of statistics. And the methods for the accident prevention were proposed on the equipment, management and user side.

A study on the Development of the Portable Device for Safety Diagnosis and Dynamic Characteristics Analysis of Elevator using Fuzzy Algorithm (Fuzzy 알고리즘을 이용한 엘리베이터 안전진단 및 동특성 분석 포터블 장비 개발)

  • 김태형;김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.199-202
    • /
    • 2001
  • An elevator system, which is essential equipment for vertical movement of an object, as a property of building, has been driven by various expenditures and purposes. Since developing electrical control technology, control system are highly developed. The elevator system has expanded widely, but a data accuracy acquisition technique and safety predict technique for securing system safety is still at a basic level. So, objective verification for elevator confidence condition requires an absolute accuracy measurement technique. Therefore, this study is executed in order to acquire a method of depending on sense of a manager with simple numeric measurement data, and to construct a logical, analytical foresight system for more efficient elevator management system. As an artificial intelligence for diagnosis, the fuzzy inference algorithm is used for foreseeing the system in this thesis, because the fuzzy algorithm is the most useful method for resolving subjective ideas and a vague judgment of humans. The fuzzy inference algorithm is developed for each sensor signal(i.e. vibration, velocity, current).

  • PDF