• 제목/요약/키워드: Element dispersion

검색결과 213건 처리시간 0.034초

입도분포에 따른 하상퇴적물의 지구화학적 분산 및 부화 (Geochemical Dispersion and Enrichment of Fluvial Sediments Depending on the Particla Size Distribution)

  • 이현구
    • 자원환경지질
    • /
    • 제32권3호
    • /
    • pp.247-260
    • /
    • 1999
  • Geochermical characteristics of the fluvial sediments deprnding on particle size distribution size were investigated in the respect of majir, minor and rare eath element chemisitry. Ratios of $Al_{2}O_{3}/Na_{2}O$ and $K_{2}O/Na_{2}O$ of the sediments show the homogeneous valus, and partly positive correlation with $SiO_{2}/Al_{2}O_{3}$, respecively. Characteristics of minor element ratios (V/Ni, Cr/V, Ni/Co and Zr/Hf)are within the lower and narrow range. Thesesuggested that sediment sources may be acidic to intermediate granitic rock, and may be explained by simple weathering and sedimentation. With increasing SiO2 contents, concentrations of $Al_{2}O_{3}$, $Fe_{2}O_{3}$, CaO and MgO decreased, but those of $K_{2}O$ and $Na_{2}O$ increased, Concentrations of Ba, Be, Cs, Cu, Li, Ni, Sr, V and Zr show comparatively normal negative and some positive trends. Compared with the mean composition of granite, concentrations of $Al_{2}O_{3}$, $Fe_{2}O_{3}$, MnO, CaO and MgO in the sediments of the study area were highly enriced. Among some minor and rare earth elements, concentrations of As, Cd, Cu, and V were enriched, but those of Be, Ce, Rb, Sc, Sr and Zn were depleted when compared with average composition of granite. By decreasing of particle size fractions, SiO2, Rb and Sr conterts decreased, but concentrations of $Al_{2}O_{3}$, $Fe_{2}O_{3}$, CaO, MgO, $TiO_{2}$, MgO, $P_{2}O_{5}$, Be, Cu, Hf, Pb, V and Zr increased. From the correlations between particle size fractions and element concenreations, some elements of $Fe_{2}O_{3}$, CaO, MgO, $P_{2}O_{5}$, Cu, Ni, Zn and Zr showed typical trends in the secondary contramination sediments. These trends are typically shown under 100 mesh fractions. It indicates that the fraction of minus 100 mesh is the optimum size fraction for geochemical and environmental survey.

  • PDF

성견 경골에서 최적화 기법을 이용하여 형상 개선된 임프란트의 조직계측학적 분석 (Histomorphometric evaluation of the implant designed by shape optimization technique)

  • 권혁락;문상권;심준성;안세영;이훈;김한성;최성호;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.35-48
    • /
    • 2004
  • Since the occlusal loading is transmitted to the surrounding bone, the success of an implant treatment is closely related to the distribution of the stress on the implant. The finite element analysis method is often used in order to produce a model for dispersion of stress. Assessment of the success of the implant is usually based on the degree of osseointegration which is a bone and implant surface interface. Implant used in this research was designed through the method of shape optimization after the stress on implant was anaylzed by the finite element analysis method. This study was pertinently assessed by a clinical, histologic, histomorphometric analysis after the shape optimized implant was installed on beagle dog tibia. The results are as follows 1. It clinically showed a good result without mobility and imflammatory reaction. 2. Implant was supported by dense bone and bone remodeling showed on the surrounding area of the implant 3. The average percentage of bone-implant contact was 58.1%.The percentage of bone density was 57.6%. Having above results, shape optimized implant showed the pertinence through clinical and histologic aspects. However, to use the shape optimized implant, the further experiment is required for finding problems, improvement.

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.

준 실시간 측정시스템을 이용한 미세입자 원소성분 배출특성 조사 (Emission Characteristics of Elemental Constituents in Fine Particulate Matter Using a Semi-continuous Measurement System)

  • 박승식
    • 한국대기환경학회지
    • /
    • 제26권2호
    • /
    • pp.190-201
    • /
    • 2010
  • Fine particulate matter < $1.8{\mu}m$ was collected as a slurry using the Semicontinuous Elements in Aerosol Sampler with time resolution of 30-min between May 23 and 27, 2002 at the Sydney Supersite, Florida, USA. Concentrations of 11 elements, i.e., Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Se, and Zn, in the collected slurry samples were determined off-line by simultaneous multi-element graphite furnace atomic absorption spectrometry. Temporal profiles of $SO_2$ and elemental concentrations combined with meteorological parameters such as wind direction and wind speed indicate that some transient events in their concentrations are highly correlated with the periods when the plume from an animal feed supplement processing facility influenced the Sydney sampling site. The peaking concentrations of the elemental species during the transient events varied clearly as the plume intensity varied, but the relative concentrations for As, Cr, Pb, and Zn with respect to Cd showed almost consistent values. During the transient events, metal concentrations increased by factors of >10~100 due to the influence of consistent plumes from an individual stationary source. Also the multi-variate air dispersion receptor model, which was previously developed by Park et al. (2005), was applied to ambient $SO_2$ and 8 elements (Al, As, Cd, Cr, Cu, Fe, Pb, and Zn) measurements between 20:00 May 23 and 09:30 May 24 when winds blew from between 70 and $85^{\circ}$, in which animal feed processing plant is situated, to determine emission and ambient source contributions rates of $SO_2$ and elements from one animal feed processing plant. Agreement between observed and predicted $SO_2$ concentrations was excellent (R of 0.99; and their ratio, $1.09{\pm}0.35$) when one emission source was used in the model. Average ratios of observed and predicted concentrations for As, Cd, Cr, Pb, and Zn varied from $0.83{\pm}0.26$ for Pb to $1.12{\pm}0.53$ for Cd.

연구로용 우라늄실리사이드 분산형 핵연료의 팽윤모델 (A Comprehensive Swelling Model of Silicide Dispersion Fuel for Research Reactor)

  • Woan Hwang;Suk, Ho-Chun;Jae, Won-Mok
    • Nuclear Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.40-51
    • /
    • 1992
  • 연구용 원자로의 분산형 핵연료에 대한 노내 조사 거동의 주요 특성중의 하나는 핵연료심 팽윤에 기인된 핵연료봉 직경 증가이다. 본 논문에서는 분산형 우라늄실리사이드 핵연료에 대한 노내 조사거 동과 실험 증거들을 분석함으로써 그 핵연료의 팽윤에 대한 물리적 해석 모형인, DFSWELL 전산 모형을 개발하였다. 문헌에 보고된 실험 증거들로부터 노내에서 U$_3$Si-Al 핵연료심의 부피변화는 온도와 핵분열율에 따라 크게 영향을 받는 것으로 나타났다. 분산형 우라늄 실리사이드 핵연료에 대한 정량적 팽윤량은 주어진 온도, 핵분열율, 핵분열고체생성물 측적 및 핵분열기체 기포거동을 고려함으로써 평가될 수 있다. 연구로의 분산형 우라늄실리사이드 핵연료의 팽윤 현상은 다음과 같은 세 가지 현상으로 귀결된다. i ) 핵분열기체생성물 기포 생성/축적에 치한 부피변화 ii ) 고체 핵분열생성물의 축적 및 상 변화에 의한 부피변화 iii ) 핵연료 입자와 기지 사이의 공유층에 대한 부피변화 상기 세 가지의 물리 적 현상을 고려하는 본 DFSWELL 전산 모형의 출력이력 조건에 따른 절대 예측치들은 실행 결과와 비교할 때 분산형 우라윰실리 사이드 핵연료의 조사추 팽윤 실측치와 잘 일치한다.

  • PDF

Ultrasonic guided wave approach incorporating SAFE for detecting wire breakage in bridge cable

  • Zhang, Pengfei;Tang, Zhifeng;Duan, Yuanfeng;Yun, Chung Bang;Lv, Fuzai
    • Smart Structures and Systems
    • /
    • 제22권4호
    • /
    • pp.481-493
    • /
    • 2018
  • Ultrasonic guided waves have attracted increasing attention for non-destructive testing (NDT) and structural health monitoring (SHM) of bridge cables. They offer advantages like single measurement, wide coverage of acoustical field, and long-range propagation capability. To design defect detection systems, it is essential to understand how guided waves propagate in cables and how to select the optimal excitation frequency and mode. However, certain cable characteristics such as multiple wires, anchorage, and polyethylene (PE) sheath increase the complexity in analyzing the guided wave propagation. In this study, guided wave modes for multi-wire bridge cables are identified by using a semi-analytical finite element (SAFE) technique to obtain relevant dispersion curves. Numerical results indicated that the number of guided wave modes increases, the length of the flat region with a low frequency of L(0,1) mode becomes shorter, and the cutoff frequency for high order longitudinal wave modes becomes lower, as the number of steel wires in a cable increases. These findings were used in design of transducers for defect detection and selection of the optimal wave mode and frequency for subsequent experiments. A magnetostrictive transducer system was used to excite and detect the guided waves. The applicability of the proposed approach for detecting and locating wire breakages was demonstrated for a cable with 37 wires. The present ultrasonic guided wave method has been found to be very responsive to the number of brokenwires and is thus capable of detecting defects with varying sizes.

통가열도 TA26 해저산의 모암변질과 원소분산 (Element Dispersion and Wallrock Alteration of TA26 Seamount, Tonga Arc)

  • 유봉철;최헌수;고상모
    • 자원환경지질
    • /
    • 제44권5호
    • /
    • pp.359-372
    • /
    • 2011
  • 통가열도의 남단에 위치하는 TA26 해저산은 열수활동이 가장 활발한 것으로 알려진 해저산으로 열수플룸이 광범위하게 존재하며 열수광석 및 열수변질암이 채취된 지역이다. 이 지역에서 채취한 암석들은 현무암내지 현무암질 안산암이다. 열수용액에 의한 변질암석시료에서는 사장석, 휘석류, 황철석, 티탄철석, 비결정질 살리카, 중정석, 녹점토, iron sulfates, Fe-Si sulfates 및 Fe silicates 등이 산출된다. 모암변질시 열수작용에 의한 변질 암석의 주원소, 미량원소 및 희토류원소 이득 및 손실을 계산하면, $K_2O$(+0.04~+0.45 g), $SiO_2$(-6.52~+10.56 g), $H_2O$(-0.03~+6.04 g), $SO_4$(-0.46~+17.54 g), S(-0.46~+13.45 g) 및 총 S(-0.51~+16.93 g)들이 모암변질시 이득되었다. 또한 미량원소들 중 특히 Ba(-7.60~+185078.62 g), Sr(-36.18~+3033.08 g), Ag(+54.83 g), Au(+1467.49 g), As(-5.80~+1030.80 g), Cd(+249.78 g), Cu(-100.57~+1357.85 g), Pb(+4.91~+532.65 g), Sb(-0.32~+66.59 g), V(-113.58~+102.94 g), 및 Zn(-49.56~+14989.92 g)들이 모암변질시 이득되었다. 따라서 이득된 주원소 및 미량원소의 종류 및 함량($K_2O$, $H_2O$, $SO_4$, S, 총 S, Ba, Sr, Ag, Au, As, Cd, Cu, Pb, Sb, V, Zn) 등을 지시원소로서 활용하면 통가열도 심해저 열수광상 탐사시 유용하게 이용될 수 있다.

일차원과 이차원 Ka-대역 프린티드 다이폴 배열 안테나의 스캔 블라인드니스 분석 (Scan Blindness Analysis of 1D and 2D Ka-Band Printed Dipole Array Antenna)

  • 구한이;송성찬;남상욱
    • 한국전자파학회논문지
    • /
    • 제30권3호
    • /
    • pp.202-208
    • /
    • 2019
  • 본 논문에서는 일차원 배열과 이차원 배열일 때 프린티드 다이폴의 스캔 블라인드니스 특성을 분석한다. 먼저 시뮬레이션을 이용하여 일차원과 이차원 배열일 때 프린티드 다이폴안테나의 능동소자패턴을 구한다. 이차원 배열에서는 E-면 방향으로 스캔 블라인드니스가 ${\pm}36^{\circ}$ 부근에서 발생하였으나, 일차원 배열에서는 스캔 블라인드현상이 거의 관측되지 않았다. 이차원 스캔 블라인드니스 원인을 분석하기 위해 먼저 이차원 배열의 단위 셀 분산 특성을 구하고, 주파수에 따른 스캔 블라인드니스와 비교한다. 그리고 일차원 배열과 이차원 배열에서의 단위 셀에서 Q 값을 비교함으로써 일차원과 이차원 배열에서 스캔 블라인드현상 차이를 설명한다. 선형으로 배열된 다이폴 구조에서 두 포트 사이에 아홉 개의 소자가 떨어져 있을 때 E-면 방향으로 전기장의 커플링을 시뮬레이션을 통하여 관측함으로써 이론의 타당성을 보인다. 마지막으로 프린티드 다이폴 배열을 제작하고, $11{\times}1$ 부배열과 $11{\times}3$ 부배열에 대해 능동소자패턴을 각각 측정하여, 시뮬레이션 결과와 비교함으로 이론을 검증한다.

수중에서 정방형 격자를 갖는 2차원 포노닉 크리스탈의 음향 밴드 구조 (Acoustic Band Structures in Two-dimensional Phononic Crystals with a Square Lattice in Water)

  • 김윤미;이강일;강휘석;윤석왕
    • 한국음향학회지
    • /
    • 제34권5호
    • /
    • pp.335-342
    • /
    • 2015
  • 포노닉 크리스탈이란 기저물질 내에 주기적으로 배열된 산란체로 구성된 복합물질로서 포노닉 크리스탈에 입사된 음파가 특정 주파수 대역에서 차단되는 현상인 밴드 갭이라는 중요한 특성을 갖는다. 본 연구에서는 수중에서 산란체로서 1 mm의 직경을 갖는 원기둥 형태의 스테인리스 스틸 막대가 1.5 mm의 격자상수를 가지며 정방형으로 배열된 2차원 포노닉 크리스탈의 음향 밴드 구조를 이론 및 실험적으로 고찰하였다. 2차원 포노닉 크리스탈의 밴드 구조를 예측하기 위해 유한요소법을 이용하여 첫째 브릴루앙 영역의 ${\Gamma}X$ 방향에 대해 주파수와 파동벡터에 대한 분산관계를 계산하였다. 초음파가 입사되는 방향과 수직한 스테인리스 스틸 막대 층의 개수를 1, 3, 5, 7, 9개로 변화시켜가며 투과계수 및 반사계수를 측정하였다. 계산된 분산관계로부터 2 MHz 이하의 주파수 대역에서 5개의 밴드 갭이 존재하는 것으로 예측되었으며, 첫째 밴드 갭은 0.5 MHz를 중심으로 나타났다. 투과계수 및 반사계수로부터 실험적으로 확인된 밴드 갭은 분산관계로부터 예측된 밴드 갭과 잘 일치하는 것으로 나타났다.

초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로) (Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements))

  • 이경성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권2호
    • /
    • pp.117-124
    • /
    • 2014
  • 본 연구는 초음파 진단 장치에서 초음파 프로브 소자의 결함이 도플러 영상에 미치는 영향을 평가한 것이다. 초음파 프로브 소자결함의 여러 유형 중에서 동일한 방식으로 단선된 초음파 프로브 소자 수를 변화하면서, 도플러 모드 영상에 미치는 영향을 실험으로 살펴보았다. 실험 결과는 첫째, 소자 결함에 따른 도플러 속도는 도플러 소자군 부분에서 급격히 변화하고 있으며, 혈류 속도에는 크게 영향을 받지 않는 것으로 나타났다. 둘째, 도플러 소자군 주변에서 결함 있을 때 소자의 번호가 높은 쪽 소자의 결함에 의한 효과가 작은 것을 알 수 있었다. 셋째, 팬텀의 혈류 속도가 높을수록 도플러 속도 스펙트럼의 폭은 커지지만 크기는 감소하고 있다. 그리고 결함이 증가할수록 도플러 속도와 영상의 밝기의 분산이 더 커지는 것으로 나타났다. 이는 프로브 소자의 결함이 증가하면 전체적으로 시간 평균 도플러 속도 프로파일(TADVP)의 크기가 감소하며 고주파수 영역에서 더 빨리 떨어지는 것으로 알 수 있다.