• Title/Summary/Keyword: Electronic needle

Search Result 173, Processing Time 0.03 seconds

Frequency Spectrum Analysis of Series Arc and Corona Discharges (직렬 아크 및 코로나 방전의 주파수 스펙트럼 분석)

  • Kil, Gyung-Suk;Jung, Kwang-Seok;Park, Dae-Won;Kim, Sun-Jae;Han, Ju-Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.554-559
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic pulses generated by series arc- and corona- discharges as a basic study to develop an on-line diagnostic technique for power facilities installed inside closed-switchboards. To simulate series arc and corona discharges, five types of electrode system which consists of needle and plane electrodes were arranged. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an ultra log antenna and an EMI receiver. From the experimental results, the frequency spectrum exists in ranges from 30 MHz to 2 GHz for a series arc discharge and 30 MHz to 1.2 GHz depending on defects for a corona discharge. The peak frequency of the series arc- and corona- discharges were 100 MHz to 160 MHz and 40 MHz to 80 MHz, respectively.

Synchronous Control of Center Distributed Multi-Head Embroidery Machine Using Disturbance Observer (외란 관측기를 이용한 중앙 분산형 다두 자수기의 동기제어)

  • Jeong, Seung Hyun;Choi, Deuk-Sung;Park, Jung Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.11
    • /
    • pp.1015-1021
    • /
    • 2014
  • This paper proposes the center distributed embroidery machine structure with 1,500 RPM, 52 heads for productivity and large sized embroidery goods. The synchronous velocity controller is adopted for control of the 2-axis distributed embroidery machine and the DOB(Disturbance Observer) is also adopted for minimizing disturbances caused by needle cams. For driving experiments of 2-axis center distributed driving structure, two conventional 26 heads 1,500RPM embroidery machines are used. It was shown that the center distributed driving structure with 2-axis synchronous control can be one way for implementing a large embroidery machine.

Development of Visual Inspection System for Minte needle probe (미세 탐침의 검사 시스템 개발)

  • Kang, Su-Min;Park, Se-Hyuk;Huh, Kyung-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.123-124
    • /
    • 2008
  • The appearance inspection of various electronic products and parts has been executed by the eyesight of human. But inspection by eyesight can't bring about uniform inspection result. Because the appearance inspection result by eyesight of human is changed by condition of physical and spirit of the checker. So machine vision inspection system is currently used to many appearance inspection fields instead of the checker. Therefore we proposes a inspection system in this paper. it will be able to secure the objectivity of the prosecuting attorney using inspection system. Also this system has been developed only using PC, CCD Camera and Visual C++ for universal workplace.

  • PDF

Characteristics of AC Treeing for Three Epoxy Resins for High Voltage Heavy Electric Machine Appliances (고전압 중전기기용 에폭시 수지 3종에 대한 교류트리잉 파괴특성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1322-1329
    • /
    • 2018
  • In this paper, the reliability test of three kinds of epoxy resin for GIS Spacer, which is a high voltage based heavy electric machine, AC electrical treeing experiments were performed. Three types of epoxy resins, Araldite B41, CT 5531 CI and B46, have slight viscosity differences. An non-uniform electric field, E = 1149.4 kV/mm, as the needle to plate electrode, a power source with a frequency of 1 kHz was applied to the tree electrode for accelerated deterioration. The treeing phenomena of the three kinds of epoxy resin all initiated, propagated, and destroyed by the branch tree. Epoxy Resin B46 was 145 times longer than B41 and 53 times longer than CT 5531CI. I think that the choice of epoxy resin is very important in choosing high voltage heavy electric machine insulation materials.

The Study of Low Temperature Firing Glass-Ceramics Substrate in Lithium Fluorhectorite

  • Choi, J-H;Park, D-H;Kim, B-I;Kang, W-H
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 1999.11a
    • /
    • pp.111-115
    • /
    • 1999
  • The $Li_2O-MgO-MgF_2-SiO_2$glasses with addition of $B_2O_3$ were investigated in order to make glass-ceramics for low temperature firing substrate. Glasses were made by melting at $1450^{\circ}C$ in the electronic furnace and crystallized at $750^{\circ}C$. After the crystallization, crystal phases and microstructure were observed. The crystal phases were polycrystalline of lithium boron fluorphlogopite and lithium fluorhectorite. The crystal shape was changed to grande type from needle type with the increase in $B_2O_3$ contents. Average particle size of the glass-ceramics aftar water swelling was $3.77{\mu}{\textrm}{m}$. The optimum sintering temperature and sintering shrinkage of the substrate were $900^{\circ}C$ and 13.4vol%, respectively.

  • PDF

Development of ECS-NIBP-$SpO_2$ Patient Monitoring System (ECG-NIBP-$SpO_2$ 환자감시장치 개발)

  • Kim, N.H.;Shin, W.H.;Lee, G.K.;Ra, S.W.;Kim, G.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.129-130
    • /
    • 1998
  • In this paper, We designed the ECG-NIBP-$SpO_2$ patient monitor. This production can measure Electrocardiograph, Heart Rate, Noninvasive Blood Pressure, and Oxygen Saturation for Noninvasive Mehod and can display each information. These informations were implemented by the electrodes of ECG part, the cuff of NIBP module and the finger probe with light sensor of $SpO_2$ without injection of needle or catheter. In addition, We developed a new analysis algorithm and measurement technique for NIBP and $SpO_2$ to observe patient's conditions correctly.

  • PDF

The Fabrication of Low Temperature Firing Substrate of $Li_2O-MgO-MgF_2-SiO_2-B_2O_3$ system

  • Park, Jung-Houn;Park, Dae-Hyun;Kang, Won-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.4
    • /
    • pp.35-39
    • /
    • 1999
  • The $Li_2O-MgO-MgF_2-SiO_2$glasses with addition of $B_2O_3$ were investigated in order to make glass-ceramics for low temperature firing substrate. Glasses were made by melting at $1450^{\circ}C$ in the electronic furnace and crystallized at $750^{\circ}C$. The crystal phases were polycrystalline of lithium boron fluorphlogopite and lithium fluorhectorite. The crystal shape was chanced to granule type from needle type with increasing $B_2O_3$ content. Average particle size of the glass-ceramics after water swelling was 3.77$\mu\textrm{m}$. The optimum sintering temperature and sintering shrinkage of the substrate were $900^{\circ}C$ and 13.4%, respectively.

  • PDF

A Possible Application of the Nonuniform Electric Field Measurement Using Laser Interferometer and Pockels Effect (레이저 간섭계와 포켈스 효과를 이용한 불평등 전계 측정)

  • Gang, Won-Jong;Gu, Ja-Yun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.6
    • /
    • pp.240-245
    • /
    • 2002
  • In this paper, a novel optical measuring system for the measurement of nonuniform electric field was proposed. The electric field distorted by the discharges was detected through proposed optical measuring system based on the Pockets effect and Mach-Zehnder interferometer. In order to produce distorted electric field, corona discharge was generated from needle-plane electrode in air and detected by optical measuring system. This optical measuring system is constructed by He-Ne laser, single mode optical fiber, $2{\times}2$ 50/50 beam splitter, $LiNbO_3$ Pockets cell, photo detector and PC. In this system, output signal of Pockels sensor is measured by digital oscilloscope and transferred to the PC for recording and statistical processing. Through this paper, a promising possibilities of proto-type optical measuring system were evinced.

Effects of Working Fuel Temperature on Injection Characteristics of Bypass Type Piezo Injector (작동 연료온도가 Bypass type 피에조 인젝터의 분사 특성에 미치는 영향)

  • Cho, Insu;Lee, Jinwook
    • Journal of ILASS-Korea
    • /
    • v.24 no.2
    • /
    • pp.66-72
    • /
    • 2019
  • Diesel vehicles suffer from poor starting and running problems at cold temperatures. Diesel vehicles have the characteristic that CO and PM are reduced or similarly discharged when going from low temperature to high temperature. In this study, a bypass type piezo injector for electronic control based common rail injection system was used. Numerical analysis using injector drive analysis model was performed to analyze injector drive and internal fuel flow characteristics according to fuel temperature change. The results show that the rate of density change due to the fuel temperature is proportional, and that the effect of the kinematic viscosity is relatively large between $-20^{\circ}C$ and $0^{\circ}C$. Comparing the results of temperature condition at $0^{\circ}C$ and $20^{\circ}C$, it is considered that the viscosity is more correlated with the needle displacement than the pressure chamber of the delivery chamber.

Diagnostic Accuracy of Ultrasonograph Guided Fine-needle Aspiration Cytologic in Staging of Axillary Lymph Node Metastasis in Breast Cancer Patients: a Meta-analysis

  • Wang, Xi-Wen;Xiong, Yun-Hui;Zen, Xiao-Qing;Lin, Hai-Bo;Liu, Qing-Yi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.11
    • /
    • pp.5517-5523
    • /
    • 2012
  • Purpose: To evaluate the diagnostic accuracy of ultrasonograph and fine-needle aspiration cytologic examination (USG-FNAC) in the staging of axillary lymph node metastasis in breast cancer patients.Methods: We conducted an electronic search of the literature addressing the performance of USG-FNAC in diagnosis of axillary lymph node metastasis in databases such as Pubmed, Medline, Embase, Ovid and Cochrane library. We introduced a series of diagnostic test indices to evaluate the performance of USG-FNAC by the random effect model (REM), including sensitivity, specificity, likelihood ratios, and diagnostic odds ratios and area under the curve (AUC). Results: A total of 20 studies including 1371 cases and 1289 controls were identified. The pooled sensitivity was determined to be 0.66 (95% CI 0.64-0.69), specificity 0.98 (95% CI 0.98-0.99), positive likelihood ratio 22.7 (95% CI 15.0-34.49), negative likelihood ratio 0.32 (95% CI 0.25-0.41), diagnostic OR 84.2 (95% CI 53.3-133.0). Due to the marginal threshold effect found in some indices of diagnostic validity, we used a summary SROC curve to aggregate data, and obtained a symmetrical curve with an AUC of 0.942. Conclusion: The results of this meta-analysis indicated that the USG-FNAC techniques have acceptable diagnostic validity indices and can be used for early staging of axillary lymph node in breast cancer patients.