• Title/Summary/Keyword: Electronic needle

Search Result 173, Processing Time 0.022 seconds

Properties of Partial Discharge accompanying with Electrical Tree in LDPE (저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성)

  • 이광우;박영국;강성화;장동욱;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

A Study on Development of the Lightning Warning System (뇌운경보장치 개발에 관한 연구)

  • Kil Gyung-Suk;Song Jae-Yong;Kim Il-Kwon;Moon Seung-Bo;Cha Myung-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.274-277
    • /
    • 2006
  • This paper describes a lighting warning system (LWS) which consists of a corona needle electrode, a low noise differential amplifier, an A/D converter, an one-chip microprocessor, a LCD and alarm devices. The corona needle electrode is used to measure electric field intensity caused by thunderclouds on the ground level. To evaluate the sensitivity of the LWS, calibration experiment was carried out using a round-shape parallel plate electrode system. The theoretical and experimental results show that the LWS can measure electric field intensity over 2 [kV/m].

  • PDF

Structural Properties of Dielectric Barrier Reactor with Hole (DBH) for CF4 Decomposition

  • Jung Jung Gun;Kim Jong Suk;Park Jae Yoon;Kim Kwang Soo;Rim Geun Hie
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.4
    • /
    • pp.30-35
    • /
    • 2003
  • In this paper, the $CF_4$ decomposition efficiency is investigated for three simulated plasma reactors that are needle plate reactor, metal particle reactor, and dielectric barrier reactor with hole (DBH). The$CF_4$ decomposition efficiency by DBH is much better than that by needle plate reactor or metal particle reactor. When applied voltage is increased up to the critical voltage for spark formation in the all reactors, the $CF_4$ decomposition efficiency is increased. The $CF_4$ decomposition efficiency in needle plate reactor and metal particle reactor is about $12\%$ and $22\%$ respectively at applied voltage of 23 kV (consumption power: 110 W) and $CF_4$ concentration of 500 ppm, however, the $CF_4$ decomposition efficiency is more than $95\%$ in case of DBH. DBH should be much better than two reactors investigated for $CF_4$ decomposition.

Development of Automatic Visual Inspection System for Micro Needle (미세 탐침의 비전 자동 검사 시스템 개발)

  • Kang, Su-Min;Han, Kwang-Hee;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.16-25
    • /
    • 2008
  • The micro needle means the ultrafine probe of 'Probe Card'. The size of micro needle is so minute that it is difficult to minute that it is difficult to inspect it with eyes. On the other hand it is very critical if there is a defect in micro needle of probe card. In this study, we developed an automatic visual inspection system for finding defect status in probe angle, tip length and diameter. Through the experimental results, we could find that our proposed method is better than human-eyes inspection method in accuracy and inspection speed, and also in robustness to lighting circumstances.

Fabrication of Spherical Microlens Array Using Needle Coating for Light Extraction of OLEDs (니들 코팅을 이용한 OLED 광 추출용 구형 마이크로렌즈 어레이 제작)

  • Kim, Juan;Shin, Youngkyun;Kim, Gieun;Hong, Songeun;Park, Jongwoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.2
    • /
    • pp.25-31
    • /
    • 2022
  • By an aid of needle coating, we have fabricated a spherical microlens array using poly(methyl methacrylate) for potential applications in light extraction of organic light-emitting diodes. With an attempt to achieve high-density and high-aspect-ratio microlens arrays, we have investigated the coating behaviors by varying the material parameters such as the solute concentration and wettability of the poly(methyl methacrylate) solution and process parameters such as the dwell time of needle near the substrate, retract distance of needle from the substrate, and coating gap between the needle and substrate. Under the optimized coating conditions, it is demonstrated that high-aspect-ratio microlens arrays can be obtained using a coating solution with high solute concentration and a small amount of a hydrophobic solvent. It is found that the diameter and height of microlens array are decreased with increasing poly(methyl methacrylate) concentration, yet the overall aspect ratio is rather enhanced. By the addition of 5 wt% hexylamine in 35 wt% poly(methyl methacrylate) solution, we have achieved a spherical microlens with the height of 7.7 ㎛ and the width of 94.24 ㎛ (the aspect ratio of 0.082). To estimate the capability of light extraction by the microlens array, we have performed ray tracing simulations and demonstrated that the light extraction efficiency of organic light-emitting diode is expected to be enhanced up to 24%.

The Characteristics of Temperature Variation in Electronic Warm Acupuncture Device (전기식 온침기의 온도 변화 특성에 관한 연구)

  • Ja-Ha Lee;Jeong-Hyun Moon;U-Ryeong Chung;Soo-Hwa Hong;Gyoungeun Park;Byung Wook Lee;Won-Suk Sung;Jong-Hwa Yoon;Eun-Jung Kim
    • Korean Journal of Acupuncture
    • /
    • v.40 no.4
    • /
    • pp.184-193
    • /
    • 2023
  • Objectives : The purpose of this study is to understand the temperature characteristics depending on the thickness and material of the needle used with the Electronic Warm Acupuncture Device (EWAD). Methods : We controlled experimental environment and measured temperature changes of a silicon phantom in which K-type thermocouples were inserted at depths of 2, 7 mm. EWAD perfomed with acupuncture needles of various thicknesses (0.25×60 mm, 0.40×60 mm, and 0.50×60 mm) and materials (Gold 0.40×50 mm). We set non-needle (only heated with EWAD skin heater) group as a control group. Results : The maximum temperature and temperature changes of 0.40 mm, 0.50 mm needle group were significantly higher than the non-needle group. The highest temperature range in all needle groups was 0.50 mm needle group (41.44±0.31℃). However, the 0.25 mm needle group was not significantly different from the non-needle group. Maximum temperature of gold needle group was significantly higher than stainless steel needle group. Temperature changes of gold needle group were higher than stainless steel group at the depth of 7 mm. Conclusions : It was found that needle thickness and material of acupuncture had an effect on the temperature of the EWAD. When performing EWAD treatment, consideration of thickness and material of acupuncture is needed. Future research is needed using phantoms that can reflect actual clinical situations and better mimic the human body.

Study on the Silicon Nano-needle Structure for Nano floating Gate Memory Application (나노 부유 게이트 메모리 소자 응용을 위한 실리콘 나노-바늘 구조에 관한 연구)

  • Jung, Sung-Wook;Yoo, Jin-Su;Kim, Young-Kuk;Kim, Kyung-Hae;Yi, Jun-Sin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1069-1074
    • /
    • 2005
  • In this work, nano-needle structures ate formed to solve problem, related to low density of quantum dots for nano floating gate memory. Such structures ate fabricated and electrical properties' of MIS devices fabricated on the nano-structures are studied. Nano floating gate memory based on quantum dot technologies Is a promising candidate for future non-volatile memory devices. Nano-structure is fabricated by reactive ion etching using $SF_6$ and $O_2$ gases in parallel RF plasma reactor. Surface morphology was investigated after etching using scanning electron microscopy Uniform and packed deep nano-needle structure is established under optimized condition. Photoluminescence and capacitance-voltage characteristics were measured in $Al/SiO_2/Si$ with nano-needle structure of silicon. we have demonstrated that the nano-needle structure can be applicable to non-volatile memory device with increased charge storage capacity over planar structures.

Oxidation-treated of Oxidized Carbons and its Electrochemical Performances for Electric Double Layer Capacitor (산화처리 탄소 및 이를 이용한 EDLC 특성)

  • Yang, Sun-Hye;Kim, Ick-Jun;Jeon, Min-Je;Moon, Seong-In;Kim, Hyun-Soo;An, Kye-Hyeok;Lee, Yun-Pyo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.6
    • /
    • pp.502-507
    • /
    • 2007
  • The oxidation treatment of several carbon materials with a sodium chlorate and 70 wt.% of nitric acid, combined with heat treatment, were attempted to achieve an electrochemical active material with a larger capacitance. Among pitch, needle coke, calcinated needle coke and natural graphite, the structure of needle coke and calacinated needle coke were changed to the graphite oxide structure with the expansion of the inter-layer. On the other hand, the calcinated needle coke after oxidation and heating at $200^{\circ}C$ has exhibited largest capacitance per weight and volume of 29.5 F/g and 24.5 F/ml at the two-electrode system in the potential range of 0 to 2.5 V. The electrochemical performance of the calcinated needle coke was discussed with the phenomenon of the electric field activation and the formation of new pores between the expanded inter-layer at first charge.

A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique (이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구)

  • Park, Jae-Jun;Jeon, Byung-Hoon;Kim, Jin-Seong;Jeon, Hyun-Gu;Baek, Kwan-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

Plating Process of Micro-needle for MEMS Probe Card (MEMS Probe Card용 Micro Needle 공정 연구)

  • Han, Myung-Soo;Ahn, Su-Chang;Nam, An-Sik;Kim, Jang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.152-152
    • /
    • 2008
  • Micro probe with Ni-Co tip was designed. Unit processes for fabricating the micro probe were developed. We are investigated the micro probe tip using by Ni-Co alloy. One-step and three-step needle was fabricated by plating process, CMP, and photolithography process. The plating thickness was varied by current density and time. Futher data will be extract by different process conditions.

  • PDF