• Title/Summary/Keyword: Electron microscope

Search Result 4,368, Processing Time 0.025 seconds

The Behavior of Secondary Electrons and Optimal Mounting Position of a Secondary Electron Detector in SEM with a Numerical Analysis (수치해석을 통한 SEM 챔버내의 이차전자 거동해석 및 이차전자 검출기의 최적 장착 위치 선정)

  • Boo, Kyeung-Seok;Jeon, Jong-Up
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.15-21
    • /
    • 2008
  • Secondary electron detectors used in scanning electron microscope accept secondary electrons emitted from the specimen and convert them to an electrical signal that, after amplification, is used to modulate the gray-level intensities on a cathode ray tube, producing an image of the specimen. In order to acquire images with good qualities, as many secondary electrons as possible should be reached to the detector. To realize this it is very important to select an appropriate mounting position and angle of the detector inside the chamber of scanning electron microscope. In this paper, a number of numerical simulations are performed to explore the relationships between detection rates of secondary electrons and the values of some parameters, such as distances between the detector and sample, relative mounting positions of scintillator positioned inside the detector with respect to detector cover, two types of mounting angles of the detector. The relationships between detection rates and applied voltages to corona ring and faraday cage, and energies of secondary electrons are investigated as well.

A Site Specific Characterization Technique and Its Application

  • Kamino, T.;Yaguchi, T.;Ueki, Y.;Ohnish, T.;Umemura, K.;Asayama, K.
    • 한국전자현미경학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.18-22
    • /
    • 2001
  • A technique to characterize specific site of materials using a combination of a dedicated focused ion beam system(FIB), and Intermediate-voltage scanning transmission electron microscope(STEM) or transmission electron microscope(TEM) equipped with a scanning electron microscope(SEM) unit has been developed. The FIB system is used for preparation of electron transparent thin samples, while STEM or TEM is used for localization of a specific site to be milled in the FIB system. An FIB-STEM(TEM) compatible sample holder has been developed to facilitate thin sample preparation with high positional accuracy Positional accuracy of $0.1{\mu}m$ or better can be achieved by the technique. In addition, an FIB micro-sampling technique has been developed to extract a small sample directly from a bulk sample in a FIB system These newly developed techniques were applied for the analysis of specific failure in Si devices and also for characterization of a specific precipitate In a metal sample.

  • PDF

A Study on the Ignition and Molten Mark Analysis of Ballast for Fluorescent Lamp (형광등용 안정기의 발화 및 용융흔 분석에 관한 연구)

  • 최충석;박창수;김혁수;김향곤;정재희
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.173-177
    • /
    • 1998
  • In this paper, we reported an outbreak of fire hazard of ballast for fluorescent lamp. The surface structure and composition of ballast coil analyzed by using metallurgical microscope, scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of molten mark appeared columnar structure and void. EDX analysis indicated that the molten mark spectra were composed not only of the corresponding original spectra but also of several new lines.

  • PDF

Numerical Analysis for the Image Evaluation of a Thermionic SEM (열전자형 주사전자현미경 결상특성의 수치해석)

  • Jung, H.U.;Park, M.J.;Kim, D.H.;Jang, D.Y.;Park, K.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.153-158
    • /
    • 2007
  • The present study covers numerical analysis of a thermionic scanning electron microscope(SEM) column. The SEM column contains an electron optical system in which electrons are emitted and moved to form a focused beam, and this generates secondary electrons from the specimen surfaces, eventually making an image. The electron optical system mainly consists of a thermionic electron gun as the beam source, the lens system, the electron control unit, and the vacuum unit. For a systematic design of the electron optical system, the beam trajectories are investigated through numerical analyses by tracing the ray path of the electron beams, and the quality of resulting image is evaluated from the analysis results.

Application of the Band-pass Filtering for Improving 3D Tomogram of Micron-thick Sections of Biological Specimens (생물시료의 3D Tomogram 정밀도 개선을 위한 Band-pass Filtering 활용)

  • Ryu, Keun-Yong;Kim, Mi-Jeong;Choi, Ki-Joo;Je, A-Reum;Kim, Soo-Jin;Lee, Chul-hyun;Jung, Hyun-Suk;Park, Jong-Won;Kweon, Hee-Seok
    • Applied Microscopy
    • /
    • v.42 no.2
    • /
    • pp.105-109
    • /
    • 2012
  • Electron tomography (ET) of biological specimens is performed from a series of images obtained over a range of tilt angles in a transmission electron microscope. When using the high voltage electron microscope (HVEM), various noises appear in EM images acquired from thick sections by high voltage electron beam. In order to obtain an adequate result in electron tomograms that allow visualization of rather complex and mega-cellular structure such as brain tissue, it is necessary to remove the noise in each original tilt images of thick section. Using band-pass filtering of original tilt images, the filtered images are obtained and used to assemble a reconstructed tomogram. The qualified 3D tomogram from filtered images results in a considerable reduction of the noises compared to conventional tomogram. In conclusion, this study suggests that band-pass filtering is effective to improve the brightness and intensity of HVEM produced tomograms acquired from micron-thick sections of biological specimens.

AN ELECTRON MICROSCOPIC STUDY OF THE IRRADIATION EFFECTS ON THE RAT PAROTID INTERCALATED DUCT CELLS (방사선조사가 타액선 도관세포에 미치는 영향에 관한 전자현미경적 연구)

  • Choi Won Jai;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.18 no.1
    • /
    • pp.137-147
    • /
    • 1988
  • This study was designed to investigate the effects of irradiation on the salivary ductal cells, especially on the intercalated ductal cells of the rat parotid glands. For this study, 36 Sprague-Dawley strain rats were irradiated on the head and neck region with absorbed dose of 15Gy by Co-60 teletherapy unit, Picker's model 4M60. The conditions irradiated were that field size, SSD, dose rate and depth were 12×5㎝m, 50㎝, 222 Gy/min. and 1㎝. respectively. The experimental animals were sacrificed 1, 2, 3, 6, 12 hours and 1, 3, 7 days after the irradiation and the changes of the irradiated intercalated duct cells of the parotid glands were examined under the light and electron microscope. The results were as follows: 1. Under the light and electron microscope, the nucleus, mitochondria and secretory granules showed severe changes in the early stage after irradiation and the most severe cellular de- generations were observed 2 hours after irradiation, but the repair processes began from 6 hours after irradiation. 2. Under the electron microscope, loss of the nuclear membranes, derrangement of the chromosomes, swelling and destruction of the secretory granules, and widening of the intercellular spaces were observed after irradiation. 3. Under the light microscope, atrophy and irregular proliferation of the ductal cells, cuboidal metaplasia, hyperchromatism, and the construction or obstruction of the lumen were observed after irradiation.

  • PDF

Enhanced Field Electron Emission from Dielectric Coated Highly Emissive Carbon Fibers

  • Almarsi, Ayman M.;Hagmann, Mark J.;Mousa, Marwan S.
    • Applied Microscopy
    • /
    • v.47 no.1
    • /
    • pp.55-62
    • /
    • 2017
  • This paper describes experiments aimed at characterizing the behavior of field electron emitters fabricated by coating carbon fibers with epoxylite resin. Polyacrylonitrile carbon fibers of type VPR-19, thermally treated at $2,800^{\circ}C$, were used. Each was initially prepared in a "uncoated" state, by standard electro polishing and cleaning techniques, and was then examined in a scanning electron microscope. The fiber was then baked overnight in a field electron microscope (FEM) vacuum chamber. Current-voltage characteristics and FEM images were recorded on the following day or later. The fiber was then removed from the FEM, coated with resin, "cured" by baking, and replaced in the FEM. After another overnight bake, the FEM characterization measurements were repeated. The coated fibers had significantly better performance than uncoated fibers. This confirms the results of earlier experiments, and is thought to be due in part to the formation of a conducting channel in the resin over layer. For the coated fiber, lower voltages were needed to obtain the same emission current. The coated fibers have current-voltage characteristics that show smoother trends, with greater stability and repeatability. No switch-on phenomena were observed. In addition, the emission images on the phosphor-coated FEM screen were more concentrated, and hence brighter.

Suppression of Melanose Caused by Diaporthe citri on Citrus Leaves Pretreated with Bio-sulfur

  • Shin, Yong Ho;Ko, Eun Ju;Kim, Su Jeong;Hyun, He Nam;Jeun, Yong Chull
    • The Plant Pathology Journal
    • /
    • v.35 no.5
    • /
    • pp.417-424
    • /
    • 2019
  • Melanose, caused by Diaporthe citri, is one of severe diseases in citrus, a major economic resource in Jeju island. To reduce the usage amount of organic synthetic fungicide, bio-sulfur was tested as an alternative chemical to control citrus melanose in the present study. Direct antifungal activity of bio-sulfur against D. citri was determined through in vitro experiment using artificial nutrient media. Disease severity of melanose on bio-sulfur pretreated citrus leaves was lower than that on untreated ones. To illustrate the mechanism of disease suppression by bio-sulfur, infection structures were observed with a fluorescent microscope and a scanning electron microscope. In fluorescent microscopic observation, most conidia rarely germinated. In addition, hyphal growth on leaves pretreated with bio-sulfur was inhibited compared to that on untreated ones. In scanning electron microscope images of bio-sulfur pretreated leaves, surfaces of most conidia were shrunk while hyphae were morphologically changed and frequently branched. Such microscopic observations were also found for leaves pretreated with a commercial fungicide Dithianon. These results suggest that bio-sulfur may be used to control citrus melanose as an environment friendly alternative to organic synthetic fungicides