• Title/Summary/Keyword: Electron irradiation

Search Result 1,014, Processing Time 0.026 seconds

Effect of surface treatments on the bond strength of indirect resin composite to resin matrix ceramics

  • Celik, Ersan;Sahin, Sezgi Cinel;Dede, Dogu Omur
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.4
    • /
    • pp.223-231
    • /
    • 2019
  • PURPOSE. The purpose of this study was to evaluate the shear bond strength (SBS) of an indirect resin composite (IRC) to the various resin matrix ceramic (RMC) blocks using different surface treatments. MATERIALS AND METHODS. Ninety-nine cubic RMC specimens consisting of a resin nanoceramic (RNC), a polymer-infiltrated hybrid ceramic (PIHC), and a flexible hybrid ceramic (FHC) were divided randomly into three surface treatment subgroups (n = 11). In the experimental groups, untreated (Cnt), tribochemical silica coating (Tbc), and Neodymium-Doped Yttrium Aluminum Garnet (Nd:YAG) laser irradiation (Lsr) with 3 W (150 mJ/pulse, 20 Hz for 20 sec.) were used as surface treatments. An indirect composite resin (IRC) was layered with a disc-shape mold ($2{\times}3mm$) onto the treated-ceramic surfaces and the specimens submitted to thermal cycling (6000 cycles, $5-55^{\circ}C$). The SBS test of specimens was performed using a universal testing machine and the specimens were examined with a scanning electron microscope to determine the failure mode. Data were statistically analyzed with two-way analysis of variance (ANOVA) and Tukey HSD test (${\alpha}=.05$). RESULTS. According to the two-way ANOVA, only the surface treatment parameter was statistically significant (P<.05) on the SBS of IRC to RMC. The SBS values of Lsr-applied RMC groups were significantly higher than Cnt groups for each RMC material, (P<.05). Significant differences were also determined between Tbc surface treatment applied and untreated (Cnt) PIHC materials (P=.039). CONCLUSION. For promoting a reliable bond strength during characterization of RMC with IRC, Nd:YAG laser or Tbc surface treatment technique should be used, putting in consideration the microstructure and composition of RMC materials and appropriate parameters for each material.

Template-free preparation of TiO2 microspheres for the photocatalytic degradation of organic dyes

  • Al Ruqaishy, Mouza;Al Marzouqi, Faisal;Qi, Kezhen;Liu, Shu-yuan;Karthikeyan, Sreejith;Kim, Younghun;Al-Kindy, Salma Mohamed Zahran;Kuvarega, Alex Tawanda;Selvaraj, Rengaraj
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.11
    • /
    • pp.2283-2289
    • /
    • 2018
  • $TiO_2$ microspheres were successfully synthesised by simple solution phase method by using various amount of titanium butoxide as precursor. The prepared $TiO_2$ were characterized by X-ray diffraction (XRD), UV-vis diffuse reflectance absorption spectra (UV-DRS), X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). XRD analysis revealed that the as-synthesized $TiO_2$ microsphere poses an anatase phase. The photocatalytic degradation experiments were carried out with three different dyes, such as methylene blue, brilliant black, reactive red-120 for four hours under UV light irradiation. The results show that $TiO_2$ morphology had great influence on photocatalytic degradation of organic dyes. The experimental results of dye mineralization indicated the concentration was reduced by a high portion of up to 99% within 4 hours. On the basis of various characterization of the photocatalysts, the reactions involved to explain the photocatalytic activity enhancement due to the concentration of titanium butoxide and morphology include a better separation of photogenerated charge carriers and improved oxygen reduction inducing a higher extent of degradation of aromatics.

A Study on Manufacturing Technique and Alloy Characteristics of Bronze Mirrors from Jeollanam-do Region in the Three Kingdoms Period (전남지역 출토 삼국시대 청동거울의 합금 특성과 제작 방법 고찰)

  • Lee, Eun Ji
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.767-777
    • /
    • 2021
  • This study analyzed the microstructures and chemical composition of three samples of bronze mirrors excavated in the Jeollanam-do region, particularly Goheung and Damyang. Under x-ray irradiation, the analysis results confirmed the broken parts and pores caused by cracks, casting, and corrosion. Major and minor elemental analysis were performed on three mirrors by Scanning electron microscopy (SEM) with Energy dispersive x-ray spectrometry (EDS) and Inductively coupled plasma mass spe ctrome try (ICP-MS). The re sult shows that the bronze mirrors containe d Cu-Sn-Pb alloys. Alpha phase and eutectic phase were observed in the microstructure, confirming that the casting was performed without additional heat treatment. Notably, Three bronze mirrors were made early Three Kingdoms period in Korea.

Ion Transmittance of Anodic Alumina for Ion Beam Nano-patterning (이온빔 나노 패터닝을 위한 양극산화 알루미나의 이온빔 투과)

  • Shin S. W.;Lee J-H;Lee S. G.;Lee J.;Whang C. N.;Choi I-H;Lee K. H.;Jeung W. Y.;Moon H.-C.;Kim T. G.;Song J. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.97-102
    • /
    • 2006
  • Anodic alumina with self-organized and ordered nano hole arrays can be a good candidate of an irradiation mask to modify the properties of nano-scale region. In order to try using porous anodic alumina as a mask for ion-beam patterning, ion beam transmittance of anodic alumina was tested. 4 Um thick self-standing AAO templates anodized from Al bulk foil with two different aspect ratio, 200:1 and 100:1, were aligned about incident ion beam with finely controllable goniometer. At the best alignment, the transmittance of the AAO with aspect ratio of 200:1 and 100:1 were $10^{-8}\;and\;10^{-4}$, respectively. However transmittance of the thin film AAO with low aspect ratio, 5:1, were remarkably improved to 0.67. The ion beam transmittance of self-standing porous alumina with a thickness larger than $4{\mu}m$ is extremely low owing to high aspect ratio of nano hole and charging effect, even at a precise beam alignment to the direction of nano hole. $SiO_2$ nano dot array was formed by ion irradiation into thin film AAO on $SiO_2$ film. This was confirmed by scanning electron microscopy that the $SiO_2$ nano dot array is similar to AAO hole array.

Effects of Low-power Laser and TDP on the Cutaneous Wound Healing (피부상처 치유에 대한 저에너지레이저와 특정전자파의 효과)

  • Ahn So-Youn;Park Sang-Ock
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.1-18
    • /
    • 1997
  • The purpose of this study is to investigate the effects of the low power Helium Neon-Infra Red(HeNe-IR) laser and the special electromagnetic therapeutic apparatus stimulation, which is usually designated as TDP by using the initial of Tending Diancibo Pu which is the Chinese inscribed with English, on wound healing in rat. The seventy-five Sprague-Dawley adult female and male rats were assigned to the experimental and control groups. Each rat was anesthetized with pentobarbital sodium, and three full-thickness incisions with 12mm length wert made on the back of the half cf the rats and three deep second degree burns were made on the back of the remainder of the rats. From 34 hours after being injured, the rats of the experimental laser group were irradiated with the 157mW electric power HeNe-IR laser for 2 minutes every day and the rats of the experimental TDP group were stimulated with TDP irradiation with the 4km spot distance for 20 minutes every day during the 17 days. The rats were sacrificed and the wound parts of its were incised on the first day, 4th day, 7th day, 10th day and 17th day respectively after the beginning of wound treatment with laser and TDP irradiation. The incised wound parts were processed appropriately for the light microscopic and electron microscopic examination. The length of incised wound was measured with microcaliper before the wound part was incised. There was a significant decrease in the length of the incised wound of the experimental laser and TDP group, compared with that of control group at 4th day, 7th day and 10th day(p<0.01) after surgery. Through the histological examination of the wound site, the more rapid epithelialization and collagen formation in experimental groups were showed, compared with control group. The histological results were analyzed and summarized as the follows; The epidermis begins to be regenerated and the granulation tissue begins to be changed to the mature pattern in the H-E stained incised skin of the laser and TDP treatment group on the 4th day. The epidermis shows the complete regeneration and the granulation tissue in the dermis in mostly to be matured in the laser and TDP treatment group on the 7th day, compared with control group. The chronic inflammatory cells are oberved and the necrosis of the collagen fibers are partially observed in control group on the 10th day. The dermis of the laser and TOP treatment group reveals relatively compactly arranged collgen bundles with the mature collagen fibers on the 10th day. The epidermis and dennis of the laser and TDP group are repaired normally and the hair follicles are well regenerated on the 17th day. The mild edema and the granulation tissue is observed in the dermis of the control groups and the delayed treatment process is observed on the 17th day. The Most of proliferated collagen fibrils are found to be compact and regular in electron micrograph of burn skin of the laser treatment group on the 10th day hut the interstitial eadema and some inflammatory cells are found in the control group. The above results suggest that through the visual and histological examination the epithelized epithelium and the proliferation of the collagen liters in the dermis occur very effectively with the low power laser treatment and the TDP treatment in the incised wound healing and the burn wound healing.

  • PDF

The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy (방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Patient dose verification is one of the most Important responsibilities of the physician in the treatment delivery of radiation therapy. For the task, it is necessary to use an accurate dosimeter that can verify the patient dose profile, and it is also necessary to determine the physical characteristics of beams used in intensity modulated radiation therapy (IMRT) The Beam Intensity Scanner (BInS) System is presented for the dosimetric verification of the two dimensional photon beam. The BInS has a scintillator, made of phosphor Terbium-doped Gadolinium Oxysulphide (Gd$_2$O$_2$S:Tb), to produce fluorescence from the irradiation of photon and electron beams. These fluoroscopic signals are collected and digitized by a digital video camera (DVC) and then processed by custom made software to express the relative dose profile in a 3 dimensional (3D) plot. As an application of the BInS, measurements related to IWRT are made and presented in this work. Using a static multileaf collimator (SMLC) technique, the intensity modulated beam (IMB) is delivered via a sequence of static portals made by controlled leaves. Thus, when static subfields are generated by a sequence of abutting portals, the penumbras and scattered photons of the delivered beams overlap in abutting field regions and this results in the creation of “hot spots”. Using the BInS, inter-step “hot spots” inherent in SMLC are measured and an empirical method to remove them is proposed. Another major MLC technique in IMRT, the dynamic multileaf collimator (DMLC) technique, has different characteristics from SMLC due to a different leaf operation mechanism during the irradiation of photon and electron beams. By using the BInS, the actual delivered doses by SMLC and DMLC techniques are measured and compared. Even if the planned dose to a target volume is equal in our experimental setting, the actual delivered dose by DMLC technique is measured to be larger by 14.8% than that by SMLC, and this is due to scattered photons and contaminant electrons at d$_{max}$.

  • PDF

Improving the efficacy of Lespedeza cuneata ethanol extract on ultraviolet-induced photoaging (야관문 에탄올 추출물의 자외선 노출에 의한 피부 광노화 개선 효과)

  • Jung, Hee Kyoung;Choi, Mi Ok;Kim, Bae Jin;Jo, Seung Kyeung;Jeong, Yoo Seok
    • Food Science and Preservation
    • /
    • v.21 no.2
    • /
    • pp.264-275
    • /
    • 2014
  • This study evaluated the improving efficacy of Lespedeza cuneata ethanol extract on skin photoaging induced by ultraviolet (UV) irradiation. The total polyphenol and flavonoid contents of the extract were respectively $134.98{\pm}1.70$ and $16.20{\pm}0.05$ mg/g, respectively. The superoxide anion radical scavenging activity and electron-donating ability of the extract were shown to be dependent on concentration, and the antioxidant ability was shown to be more effective in superoxide anion radical scavenging activity than in electron-donating ability under the same concentration conditions. In the in vivo test conducted using hairless mouse with skin photoaging induced by UVB irradiation, the skin erythema of the groups treated with the extract (AS) reduced to 28% of the control, and the skin moisture content increased to 131%.. The extract treatment of the UV-damaged skin improved the morphological and histopathological state of the skin. Furthermore, the SOD, GST and CAT activities in the skin tissue of the AS group increased, and the XO activity and TBARS generation decreased. With regard to the genes related to the photoaging skin, the expression of PAK, p38, c-Fos, c-Jun, TNF-${\alpha}$ and MMP-3 in the skin of the AS group were found to have decreased. It was therefore concluded that Lespedeza cuneata ethanol extract can reduce wrinkle formation in the skin due to the regulation of the gene expression caused by the exposure to UVB light.

Comparison of Irradiated Food with Electron Beam and Gamma-ray by PSL and TL Methods (광자극발광법과 열발광법 분석을 통한 전자선과 감마선 조사식품의 비교 연구)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Yoon, Jin-Ho;Park, Young-Eun;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.258-266
    • /
    • 2013
  • This study was conducted to determine the PSL and TL properties of foods irradiated with electron beam and gamma-ray. 5 kinds of food including cereal, pulse, fish powder, dried vegetable and tea were irradiated at 0 to 10 kGy by electron beam accelerator or $^{60}Co$ gamma-ray irradiator. The PSL analysis showed negative results for most of the non-irradiated samples. Non-irradiated shrimp powder showed intermediate result. Irradiated samples gave negative or intermediate or positive value which presented the limitation of PSL technique. In TL analysis, there were TL glow curves at around $300^{\circ}C$ with low intensity on non-irradiated samples. Maximum peak in the range of $150-250^{\circ}C$ was appeared on irradiated samples. TL ratio obtained by re-irradiation with 1 kGy was less than 0.1 on non-irradiated samples and higher than 0.1 on irradiated samples. Therefore, in PSL measurement, electron-beam irradiated samples could obtain more clear results. TL analysis showed obvious difference between non-irradiated and irradiated samples. But the identification was impossible for the sample of rice and lemon tea. Because of it's low contents of mineral.

Analysis of the Volatile Flavor Components in Plum ($Prunus$ $salicina$) Irradiated with an Electron Beam (전자선 조사한 자두의 휘발성 유기성분 변화)

  • Jeong, In-Seon;Lee, Sun-Im;Jeon, Dong-Bok;Hong, Young-Sin;Kim, Jae-Sung;Choi, Sung-Hwa;Nho, Eun-Yeong;Choi, Ji-Yeon;Kim, Byung-Sook;Kim, Kyong-Su
    • Food Science and Preservation
    • /
    • v.19 no.2
    • /
    • pp.249-256
    • /
    • 2012
  • The changes in the volatile organic compounds in plum after its electron beam irradiation and storage were determined using the simultaneous distillation extraction method and gas chromatograph-mass spectrometry. There were 44, 46, 45, 47, and 38 volatile compounds in the 0-, 0.25-, 0.5-, 0.75-, and 1 kGy irradiated samples, respectively. Also, the volatile flavor components of the plum that was stored for 30 days were identified as 48, 40, 40, 39, and 40 components. The compositions of the volatile compounds of the control and irradiated samples showed a similarity after the storage. Especially, the more important volatile flavor of the plum was identified as hexanal of the C6compounds, (E)-2-hexenal and (Z)-3-hexenal. In particular, hexanal, (E)-2-hexenal, and (Z)-3-hexen-1-ol increased in all the doses, where as hexanol and (E)-2-hexen-1-ol decreased. Among the lactone compounds, ${\gamma}$-hexalactone, ${\gamma}$-octalactone, and ${\gamma}$-decalactone were identified during the storage period in the raw samples. Hexanonic acid and 2-hexenoic acid were not identified during the storage of the samples, and 2-methylprrole was detected only when the storage samples were irradiated at a dose higher than 0.5kGy. Therefore, it was shown that there was no effect on the variation of the volatile organic component suntil 1 kGy in the plum was irradiated with an electron beam.

The 1998, 1999 Patterns of Care Study for Breast Irradiation after Mastectomy in Korea (1998, 1999년도 우리나라에서 시행된 근치적 유방 전절제술 후 방사선치료 현황 조사)

  • Keum,, Ki-Chang;Shim, Su-Jung;Lee, Ik-Jae;Park, Won;Lee, Sang-Wook;Shin, Hyun-Soo;Chung, Eun-Ji;Chie, Eui-Kyu;Kim, Il-Han;Oh, Do-Hoon;Ha, Sung-Whan;Lee, Hyung-Sik;Ahn, Sung-Ja
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To determine the patterns of evaluation and treatment in patients with breast cancer after mastectomy and treated with radiotherapy. A nationwide study was performed with the goal of improving radiotherapy treatment. $\underline{Materials\;and\;Methods}$: A web- based database system for the Korean Patterns of Care Study (PCS) for 6 common cancers was developed. Randomly selected records of 286 eligible patients treated between 1998 and 1999 from 17 hospitals were reviewed. $\underline{Results}$: The ages of the study patients ranged from 20 to 80 years (median age 44 years). The pathologic T stage by the AJCC was T1 in 9.7% of the cases, T2 in 59.2% of the cases, T3 in 25.6% of the cases, and T4 in 5.3% of the cases. For analysis of nodal involvement, N0 was 7.3%, N1 was 14%, N2 was 38.8%, and N3 was 38.5% of the cases. The AJCC stage was stage I in 0.7% of the cases, stage IIa in 3.8% of the cases, stage IIb in 9.8% of the cases, stage IIIa in 43% of the cases, stage IIIb in 2.8% of the cases, and IIIc in 38.5% of the cases. There were various sequences of chemotherapy and radiotherapy after mastectomy. Mastectomy and chemotherapy followed by radiotherapy was the most commonly performed sequence in 47% of the cases. Mastectomy, chemotherapy, and radiotherapy followed by additional chemotherapy was performed in 35% of the cases, and neoadjuvant chemoradiotherapy was performed in 12.5% of the cases. The radiotherapy volume was chest wall only in 5.6% of the cases. The volume was chest wall and supraclavicular fossa (SCL) in 20.3% of the cases; chest wall, SCL and internal mammary lymph node (IMN) in 27.6% of the cases; chest wall, SCL and posterior axillary lymph node in 25.9% of the cases; chest wall, SCL, IMN, and posterior axillary lymph node in 19.9% of the cases. Two patients received IMN only. The method of chest wall irradiation was tangential field in 57.3% of the cases and electron beam in 42% of the cases. A bolus for the chest wall was used in 54.8% of the tangential field cases and 52.5% of the electron beam cases. The radiation dose to the chest wall was $45{\sim}59.4\;Gy$ (median 50.4 Gy), to the SCL was $45{\sim}59.4\;Gy$ (median 50.4 Gy), and to the PAB was $4.8{\sim}38.8\;Gy$, (median 9 Gy) $\underline{Conclusion}$: Different and various treatment methods were used for radiotherapy of the breast cancer patients after mastectomy in each hospital. Most of treatment methods varied in the irradiation of the chest wall. A separate analysis for the details of radiotherapy planning also needs to be followed and the outcome of treatment is needed in order to evaluate the different processes.