• 제목/요약/키워드: Electron Detector

검색결과 264건 처리시간 0.032초

모 한방병원 한약재내 중금속과 이산화황 함량 및 잔류농약 분석 연구 (Analysis of Heavy Metals, Sulfur Dioxide and Residual Pesticides in Oriental Medical Materials at a Certain Oriental Medical Hospital)

  • 조웅희;차윤엽;백태현;김병우;이승기;유준상;손영주;선승호
    • 동의생리병리학회지
    • /
    • 제25권3호
    • /
    • pp.489-495
    • /
    • 2011
  • The purpose of this study was to analyze harmful heavy metals, sulfur dioxide and residual pesticides in 30 kinds of oriental medical materials. This study was carried out on 30 samples of oriental medical materials. The examination's methods fallow the guideline of Food and Drug Administration. Inductively Coupled Plasma Mass Spectrometer (ICP-OES) was used to analyze lead, arsenic, cadmium. Mercury was analyzed by amalgamation method. A modified Monier-Williams method was used to analyze sulfur dioxide. The Gas Chromatography / Electron Capture Detector (GC/ECD) was used to analyze residual pesticides. Most of the results were within normal limits at baseline. but Cadmium was detected 0.523 mg/kg more than 0.3 mg/kg in Cinnamomi ramulus and Endosulfan was detected 11.595 mg/kg more than 0.2 mg/kg in Alismatis rhizoma. We needs to keep the quality of herbal medicines assessing and controling for safety of herbal medicines.

The electronic structure of the ion-beam-mixed Pt-Cu alloys by XPS and XANES

  • Lim, K.Y.;Lee, Y.S.;Chung, Y.D.;Lee, K.M.;Jeon, Y.;Whang, C.N.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.133-133
    • /
    • 1998
  • In the thin film alloy formation of the transition metals ion-beam-mixing technique forms a metastable structure which cannot be found in the arc-melted metal alloys. Sppecifically it is well known that the studies about the electronic structure of ion-beam-mixed alloys pprovide the useful information in understanding the metastable structures in the metal alloy. We studied the electronic change in the ion-beam-mixed ppt-Ct alloys by XppS and XANES. These analysis tools pprovide us information about the charge transfer in the valence band of intermetallic bonding. The multi-layered films were depposited on the SiO2 substrate by the sequential electron beam evapporation at a ppressure of less than 5$\times$10-7 Torr. These compprise of 4 ppairs of ppt and Cu layers where thicknesses of each layer were varied in order to change the alloy compposition. Ion-beam-mixing pprocess was carried out with 80 keV Ae+ ions with a dose of $1.5\times$ 1016 Ar+/cm2 at room tempperature. The core and valence level energy shift in these system were investigated by x-ray pphotoelectron sppectroscoppy(XppS) pphotoelectrons were excited by monochromatized Al K a(1486.6 eV) The ppass energy of the hemisppherical analyzer was 23.5 eV. Core-level binding energies were calibrated with the Fermi level edge. ppt L3-edge and Cu K-edge XANES sppectra were measured with the flourescence mode detector at the 3C1 beam line of the ppLS (ppohang light source). By using the change of White line(WL) area of the each metal sites and the core level shift we can obtain the information about the electrons pparticippating in the intermetallic bonding of the ion-beam-mixed alloys.

  • PDF

Photocatalytic activity of $TiO_2$ on nano-diamond powder prepared by Atomic Layer Deposition

  • Kim, Kwang-Dae;Dey, Nilay Kumar;Seo, Hyun-Ook;Kim, Dong-Wun;Nam, Jong-Won;Sim, Chae-Won;Jeong, Myung-Geun;Kim, Young-Dok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.425-425
    • /
    • 2011
  • The photocatalytic decomposition of toluene gas was investigated with $TiO_2$ on nano-diamond powder (NDP) under UV irradiation. Atomic layer deposition (ALD) was used for the growth of $TiO_2$ on the NDP. The structure and surface properties of catalysts were characterized by X-ray Diffraction (XRD), X-ray Photoelectron Spectroscopy (XPS) and Transmission Electron Microscopy (TEM). The photocatalytic activity for the toluene decomposition was evaluated by measuring the concentration change of toluene and $CO_2$ gas with gas chromatography (GC)-flame ionization detector (FID) system. The photocatalytic activities of $TiO_2$/NDP catalysts were compared with that of P-25. The rate of initial photocatalytic decomposition of toluene for the $TiO_2$/NDP catalysts was relatively lower when compared to P-25. The photocatalytic activity of P-25 was rapidly decreased with time, whereas, the deactivation of $TiO_2$/NDP catalysts was less pronounced. Therefore, as the reaction time increased, the photocatalytic activity of $TiO_2$/NDP catalysts became higher than that of P-25. The intermediates such as benzaldehyde or benzoic acid, etc were more easily adhered to the active site on the P-25 surface during reaction, resulting in easier deactivation of P-25. These results could be confirmed using FT-IR spectroscopy. We suggest that the NDP used as substrate can reduce the deactivation of $TiO_2$ on the surface.

  • PDF

Study of Pulse Generation Technique for Serial dual Electrode Detection of Amino Acids and Proteins in Flow Injection Analysis

  • Fung, Ying-Sing;Mo, Song-Ying
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.575-582
    • /
    • 1995
  • A new analytical procedure using a serial dual electrode detector was developed for the analysis of amino acids and proteins. Bromine was generated at the upstream electrode and detected by the downstream electrode. The presence of amino acids and proteins was shown to lower the downstream current but with no apparent effect on the upstream current. This indirect mode of detection can be applied to the determination of amino acids and proteins which are electrochemically inactive or too large to be accessible to the electrode surface for electron exchange. The method is shown capable to determine various amino acids (cystine, tyrosine, lysine, tryptophan, glycine, methionine and arginine) and proteins (cytochrome c, hemoglobin, HAS, a-Amylase, Conalbumin I, Catalase and Myglobin) with linear working range for amino acids between $10^{-6}$ to $10^{-3}M$ and total proteins between $10^{-7}$ to $10^{-3}M$. The method has been applied for the analysis of amino acids and total protein in food using Flow Injection Analysis with results obtained comparable to those using the traditional analytical procedure. Use of pulse generation technique was shown to produce a more stable flow injection analysis peaks for repetitive determination than the use of conventional constant current method which showed increase of the background current after determination over 200 minutes. The pulse method was found to give stable baseline even after 400 minutes. Thus, the method is shown able to provide a suitable analytical procedure for automatic analysis of amino acids and proteins in food by flow injection analysis.

  • PDF

Residues of Diazinon in Growing Chinese cabbage: A study Under Greenhouse Conditions

  • Khay, Sathya;El-Aty, A.M. Abd;Lim, Kye-Taek;Shim, Jae-Han
    • 한국환경농학회지
    • /
    • 제25권2호
    • /
    • pp.174-179
    • /
    • 2006
  • Chinese cabbage, Braccica campestris has long been consumed as a staple food for Koreans in various forms of fresh, salted, and fermented Kimchi. Cultivation of the crop under greenhouse has become a general practices to fulfill its off-seasonal consumer's demand. However, agricultural practices of the crop have always accompanied with heavy applications of pesticides caused by severe outbreaks of diseases and pose under warm and humid circumferences. Since dissipation patterns of pesticide residues in/on the crop under greenhouse conditions ate quite different from those in the open-air, changes of diazinon, O,O-diethyl O-2-isopropyl-6-methylpyrimidin-4-yl phosphornthioate, in/on the Chinese cabbage applied by foliar spraying under greenhouse were studied. Diazinon 34% EC was applied with dilution of recommended and double dose to the crop. The shoots of crop were harvested immediately after this application and at regular intervals over a 10-day. After sample preparations, the diazinon residue was analyzed using gas chromatography equipped with electron capture detector (GC/ECD). Initially deposited amount of the chemical in/on the crop right after applications with recommended and double doses were 8.3 and 15.2 mg/kg, respectively. The residue levels after 10 days of application were 0.03 and 0.09 mg/kg with 1.3 and 1.5 days of half-life in/on the crop, respectively. In consequent 10 days of pre-harvest interval (PHI) for diazinon EC formulation in/on Chinese cabbage under greenhouse condition was fulfill maximum residue level set by Korea Food and Drug Administration (KFDA, 0.1 mg/kg).

TiO2 고정화 지지체를 이용한 Chlorothalonil의 광촉매분해 (Photocatalytic Degradation of Chlorothalonil using TiO2 Supported in Matrices)

  • 김종향;남춘동;김병관
    • 공업화학
    • /
    • 제7권4호
    • /
    • pp.750-756
    • /
    • 1996
  • $TiO_2$ 고정화 물질은 Titanium tetraisopropoxide-isopropanol 용액에 제오라이트와 glass filter를 담지한 후, 이것을 공기중에 건조시켜 $500^{\circ}C$에서 소결하여 얻었다. Chlorothalnoil의 분석은 ECD가 부착된 가스크로마토그래피로 분석하였다. Chlorothalnoil에 대한 분해효율은 $TiO_2$로 지지된 광촉매가 효과적이었고, 3시간 후 완전히 분해되었다. 반응 생성물들은 $TiO_2$로 지지된 제오라이트에서는 $Cl^-$가 5.0ppm, $TiO_2$로 지지된 glass filter에서는 $Cl^-$가 7.5ppm,그리고 $TiO_2$ 분말에서는 $Cl^-$가 2.0ppm 각각 생성되었다. 그러나, $CN^-$는 지지체의 종류에 관계없이 검출한계이하였다.

  • PDF

PBMS용 전기 동역학적 입자 집속 모듈 연구

  • 김명준;김동빈;문지훈;김태성
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.180-180
    • /
    • 2013
  • 반도체, 디스플레이와 같이 저압, 극청정 조건에서 진행되는 공정에서 발생한 오염입자는 수 율에 큰 영향을 미친다. 따라서 공정 중에 발생한 오염입자를 실시간으로 모니터링할 수 있는 장비에 대한 연구가 활발히 진행되고 있다. Particle Beam Mass Spectrometer (PBMS)는 저압에서 실시간으로 나노 입자의 크기를 측정할 수 있는 대표적인 장비 중 하나이다. 입자를 포함한 가스 유동이 PBMS로 유입되면, 우선 입자를 입자빔의 형태로 집속하는 공기역학렌즈를 통과하게 된다. 집속된 입자는 노즐에 의해서 가속되며, 이로 인해 충분한 관성을 가지게 된 입자는 양극과 음극, 필라멘트로 구성된 electron gun에서 전자충돌에 의해 포화상태로 하전된다. 하전한 입자는 electrostatic deflector에서 크기에 따라 분류되어 Faraday detector와 electrometer에 의해 측정된다. 그러나 공기역학렌즈는 입자의 크기가 작아질수록 집속 효율이 급격히 낮아진다는 문제점을 지니고 있다. 이는 입자가 작아질수록 점성에 의한 영향이 관성에 의한 영향보다 커짐으로써 나타나는 현상이다. 최근 이러한 문제점을 해결하기 위해 사중극자를 사용하여 입자를 집속시키는 방법이 대안으로 제시되었다. 사중극자는 서로 마주보는 쌍곡선 형태의 전극구조에 AC 전기장을 인가하는 방식을 사용한다. 사중극자의 중심은 정확히 평형점을 가지게 되며 입자는 사중극자 내에서 진동을 반복하며 평형점을 향해 모이게 된다. 입자의 크기가 작을수록 전기력에 의한 영향을 크게 받으므로 사중극자를 이용한 입자집속 방법은 나노입자의 집속에 있어 공기역학렌즈를 이용한 집속에 비해 이점을 지닌다. 또한 집속 하고자 하는 입자 대상이 바뀔 경우 구조를 바꿔야 하는 공기역학렌즈와 달리 사중극자를 이용한 방법은 AC 전기장을 조절하는 것 만으로 제어가 가능하다. 본 연구에서는 저압 조건에서 나노입자를 집속하기 위한 사중극자의 전극 구조를 이론적인 계산을 통하여 구하였다. 그 결과 0.1 torr의 압력 조건하에서 5~100 nm 범위의 기본 입자를 AC 전압과 진동수를 조절하여 집속할 수 있는 사중극자 형태를 설계하였다.

  • PDF

Headspace-SPME와 GC-ECD를 이용한 수중의 미량 Halonitromethane (HNM)류 분석 (Analysis of Trace Levels of Halonitromethanes (HNM) in Water using Headspace-SPME and GC-ECD)

  • 강소원;손희종;서창동;김경아;최진택
    • 대한환경공학회지
    • /
    • 제37권5호
    • /
    • pp.293-302
    • /
    • 2015
  • HNMs는 독성이 강한 소독부산물들 중의 하나로 최근에 다양한 연구가 진행되고 있다. 본 연구에서는 headspace-solid phase microextraction (SPME) 전처리장치와 GC-ECD를 이용하여 9종의 HNMs를 동시분석할 수 있는 분석법을 개발하였다. 9종의 HNMs에 대한 검출한계(LOD)는 90~260 ng/L였으며, 정량한계(LOQ)는 270~840 ng/L였다. 수돗물과 해수를 이용하여 시료수의 matrix 영향을 살펴본 결과, 9종의 HNMs에 대해 80%~127%의 양호한 회수율을 나타내어 시료수의 matrix에 영향을 받지 않았다. 또한, 본 연구에서 개발된 headspace SPME GC-ECD 분석법은 용매류를 이용한 별도의 전처리 과정이 필요하지 않아서 친환경적이며 간편하고 빠른 자동화된 방법으로 HNMs 분석에 적합한 것으로 나타났다.

일부 한국인 Debrisoquine 대사분포에 대한 연구 (A Study on the Debrisoquine Metabolism in a Group of Korean Population)

  • 이명학;문화영;손명호;손석준;최진수
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권3호
    • /
    • pp.569-579
    • /
    • 1994
  • The genetically determined ability to metabolize debrisoquine (DBR) is related to risk of lung cancer and DBR hydroxylation exhibits wide inter-individual variation. In this study, 100 korean adults were tested for their ability to metabolize DBR. The DBR metabolic phenotype were determined by metabolic ratio (MR, DBR / 4-HDBR) which is the percent dose excreted as unchanged DBR divided by the percent dose excreted as 4-hydroxyebrisoquine(4-HDBR) in a aliquot of an eight hour urine sample, after 10mg DBR test dose administration. Analysis was performed on a capillary gas chromatograph fitted with electron capture detector. The results were as follows; 1 Geometric mean of DBR MR was 0.32 in male,0.27 in female,0.30 in total and the distribution of log (MR) was seemed to follow normal distribution. 2. Metabolic ratio of DBR was higher in non-smoker and non-drinker than in smoker and drinker without any statistically significant difference. 3. None of personal factors was significantly related to DBR MR except age. 4. The DBR metabolic phenotype was extensive metabolizer(EM) 93, intermediate metabolizer(IM) 7 by traditional method and EM 98, IM 3 by Caporaso's method. The poor metabolizer (PM) phenotype was not found by either method. 5. Maximal expected PM phenotype was 0.36% by traditional method and 0.04% by Caporaso's method.

  • PDF

Wireless Communication at 310 GHz using GaAs High-Electron-Mobility Transistors for Detection

  • Blin, Stephane;Tohme, Lucie;Coquillat, Dominique;Horiguchi, Shogo;Minamikata, Yusuke;Hisatake, Shintaro;Nouvel, Philippe;Cohen, Thomas;Penarier, Annick;Cano, Fabrice;Varani, Luca;Knap, Wojciech;Nagatsuma, Tadao
    • Journal of Communications and Networks
    • /
    • 제15권6호
    • /
    • pp.559-568
    • /
    • 2013
  • We report on the first error-free terahertz (THz) wireless communication at 0.310 THz for data rates up to 8.2 Gbps using a 18-GHz-bandwidth GaAs/AlGaAs field-effect transistor as a detector. This result demonstrates that low-cost commercially-available plasma-wave transistors whose cut-off frequency is far below THz frequencies can be employed in THz communication. Wireless communication over 50 cm is presented at 1.4 Gbps using a uni-travelling-carrier photodiode as a source. Transistor integration is detailed, as it is essential to avoid any deleterious signals that would prevent successful communication. We observed an improvement of the bit error rate with increasing input THz power, followed by a degradation at high input power. Such a degradation appears at lower powers if the photodiode bias is smaller. Higher-data-rate communication is demonstrated using a frequency-multiplied source thanks to higher output power. Bit-error-rate measurements at data rates up to 10 Gbps are performed for different input THz powers. As expected, bit error rates degrade as data rate increases. However, degraded communication is observed at some specific data rates. This effect is probably due to deleterious cavity effects and/or impedance mismatches. Using such a system, realtime uncompressed high-definition video signal is successfully and robustly transmitted.