Characterization of Groundwater Colloids From the Granitic KURT Site and Their Roles in Radionuclide Migration

  • Baik, Min-Hoon;Park, Tae-Jin;Cho, Hye-Ryun;Jung, Euo Chang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.3
    • /
    • pp.279-296
    • /
    • 2022
  • The fundamental characteristics of groundwater colloids, such as composition, concentration, size, and stability, were analyzed using granitic groundwater samples taken from the KAERI Underground Research Tunnel (KURT) site by such analytical methods as inductively coupled plasma-mass spectrometry, field emission-transmission electron microscopy, a liquid chromatography-organic carbon detector, and dynamic light scattering technique. The results show that the KURT groundwater colloids are mainly composed of clay minerals, calcite, metal (Fe) oxide, and organic matter. The size and concentration of the groundwater colloids were 10-250 nm and 33-64 ㎍·L-1, respectively. These values are similar to those from other studies performed in granitic groundwater. The groundwater colloids were found to be moderately stable under the groundwater conditions of the KURT site. Consequently, the groundwater colloids in the fractured granite system of the KURT site can form stable radiocolloids and increase the mobility of radionuclides if they associate with radionuclides released from a radioactive waste repository. The results provide basic data for evaluating the effects of groundwater colloids on radionuclide migration in fractured granite rock, which is necessary for the safety assessment of a high-level radioactive waste repository.

THE EFFECT OF THE HIGH DENSITY PLASMA ON THE DIAMOND-LIKE CARBON FILMS

  • Kim, H.;D.H. Jung;Park, B.;K. C. Yoo;Lee, J. J.;J. H. Joo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.54-54
    • /
    • 2003
  • DLC films were deposited on Si(100) substrates by inductively coupled plasma (ICP) assisted chemical vapor deposition (CVD). A mixture of acetylene (C$_2$H$_2$) and argon (Ar) gases was used as the precursor and plasma source, respectively. The structure of the films was characterized by the Raman spectroscopy. Results from the Raman spectroscopy analysis indicated that the property change of the DLC films is due to the sp$^3$ and sp$^2$ ratio in the films under various conditions such as ICP power, working pressure and RF substrate bias. The hydrogen content in the DLC films was determined by an electron recoil detector (ERB). The roughness of the films was measured by atomic force microscope (Am). A microhardness tester was used for the hardness and elastic modulus measurement. The DLC film showed a maximum hardness of 37㎬. In this work, the relationship between deposition parameters and mechanical properties were discussed.

  • PDF

X-ray Absorption Near-edge Studies of Au1-xPtx alloys

  • Y.D. Chung;Lim, K.Y.;Lee, Y.S.;C.N.Whang;Park, B.S.;Y.Jeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.164-164
    • /
    • 2000
  • Since Au-Pt alloys have various atomic structures depending upon composition and annealing temperature, it is very interesting to investigate the electronic structures of alloys. We studied the changes of the electronic structure I the Au-Pt alloys by x-ray absorption near edge spectroscopy (XANES). Two kinds of Au-Pt alloy samples were prepared by arc melting methods and ion-beam-mixing technique. The Pt L2, 3-edge and Au L2, 3-edge X-ray absorption spectra (XPS) were measured with the electron yield mode detector at the 3C1 beam line of the Pohang Light Source (PLS). It was found that there was a substantial decrease in the area of the Pt L2, 3 white lines compared with that of pure Pt. The observed decrease in white line area was attributed to an increase in the number of pure Pt. The observed decrease in white line area was attributed to an increase in the number of 5d-electrons at the Pt site upon alloy formation. However, the Au L2, 3 edge spectra for Au-Pt alloys are all similar to that of pure Au. This implies that the 5d hole count of Au is not changed by alloy formation with Pt.

  • PDF

High Speed and Sensitive X-ray Analysis System with Automated Aberration Correction Scanning Transmission Electron Microscope

  • Inada, Hiromi;Hirayama, Yoichi;Tamura, Keiji;Terauchi, Daisuke;Namekawa, Ryoji;Shichiji, Takeharu;Sato, Takahiro;Suzuki, Yuya;Ohtsu, Yoshihiro;Watanabe, Keitaro;Konno, Mitsuru;Tanaka, Hiroyuki;Saito, Koichiro;Shimoyama, Wataru;Nakamura, Kuniyasu;Kaji, Kazutoshi;Hashimoto, Takahito
    • Applied Microscopy
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • We have developed a new HD-2700 (Hitachi High-Technologies Corp., Japan) scanning transmission electron microscope (STEM) that includes an automatic aberration correction function, and a large-solid-angle energy-dispersive X-ray spectroscopy detector that enables high-resolution and sensitive analysis. For observation with atomic resolution, using spherical-aberration-corrected STEM, in order that satisfactory performance of the device can be achieved readily, and within a short time, irrespective of the operator's skill level, a spherical-aberration-correction device with an automatic aberration-correction function was developed. This automatic aberration-correction function carries out the entire correction-related process (aberration measurement, selection and correction) automatically, with automatic selection of the aberrations that require correction, and automatic measurement of the appropriate corrections.

Small scale magNetospheric and Ionospheric Plasma Experiments; SNIPE mission

  • Hwang, Junga;Lee, Jaejin;Shon, Jongdae;Park, Jaeheung;Kwak, Young-Sil;Nam, Uk-Won;Park, Won-Kee
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.40.3-41
    • /
    • 2017
  • Korea Astronomy and Space Science Institute The observation of particles and waves using a single satellite inherently suffers from space-time ambiguity. Recently, such ambiguity has often been resolved by multi-satellite observations; however, the inter-satellite distances were generally larger than 100 km. Hence, the ambiguity could be resolved only for large-scale (> 100 km) structures while numerous microscale phenomena have been observed at low altitude satellite orbits. In order to resolve those spatial and temporal variations of the microscale plasma structures on the topside ionosphere, SNIPE mission consisted of four (TBD) nanosatellites (~10 kg) will be launched into a polar orbit at an altitude of 700 km (TBD). Two pairs of satellites will be deployed on orbit and the distances between each satellite will be from 10 to 100 km controlled by a formation flying algorithm. The SNIPE mission is equipped with scientific payloads which can measure the following geophysical parameters: density/temperature of cold ionospheric electrons, energetic (~100 keV) electron flux, and magnetic field vectors. All the payloads will have high temporal resolution (~ 16 Hz (TBD)). This mission is planned to launch in 2020. The SNIPE mission aims to elucidate microscale (100 m-10 km) structures in the topside ionosphere (below altitude of 1,000 km), especially the fine-scale morphology of high-energy electron precipitation, cold plasma density/temperature, field-aligned currents, and electromagnetic waves. Hence, the mission will observe microscale structures of the following phenomena in geospace: high-latitude irregularities, such as polar-cap patches; field-aligned currents in the auroral oval; electro-magnetic ion cyclotron (EMIC) waves; hundreds keV electrons' precipitations, such as electron microbursts; subauroral plasma density troughs; and low-latitude plasma irregularities, such as ionospheric blobs and bubbles. We have developed a 6U nanosatellite bus system as the basic platform for the SNIPE mission. Three basic plasma instruments shall be installed on all of each spacecraft, Particle Detector (PD), Langmuir Probe (LP), and Scientific MAGnetometer (SMAG). In addition we now discuss with NASA and JAXA to collaborate with the other payload opportunities into SNIPE mission.

  • PDF

Feasibility Study of Modifying Diagnostic Radiation Dose using Magnetic Field (자기장을 이용한 진단방사선 선량 변화 가능성 연구)

  • Jeong-Min Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.5
    • /
    • pp.509-513
    • /
    • 2024
  • This study investigated the feasibility of applying the changes in electron dose distribution, observed in high-energy therapeutic radiation using magnetic fields, to low-energy diagnostic radiation. The diagnostic X-ray exposure conditions were set with a tube current of 200 mA, source-to-detector distance (SDD) of 100 cm, exposure time of 1.0 sec, and an irradiation field size of 20 × 20 cm2. The tube voltage was varied from 70 to 100 kVp in 10 kVp increments. A 0.5 T permanent Nd magnet was used to create a magnetic field below the collimator. Measurements were repeated 20 times for each tube voltage, both with and without the magnetic field, and were compared using an independent-samples t-test. While slight differences of dose were observed at tube voltages of 70, 80, and 90 kVp, no statistically significant differences were found (p > .05). However, a significant difference was observed at 100 kVp (p = .048). Based on these findings, it is suggested that applying higher energy, longer exposure times, stronger magnetic fields, and high-performance detectors could potentially modify the electron dose distribution in diagnostic radiation. This could contribute to dose reduction for patients and improvement in the quality of medical imaging.

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF

Monitoring and Risk Assessment of Pesticide Residues Farmers' Market Produce in Northern Gyeonggi-do (경기 북부 내 직거래 농산물의 잔류농약 실태조사 및 위해성 평가)

  • Lim, Jeong-Hwa;Park, Po-Hyun;Lim, Bu-Geon;Ryu, Kyong-Shin;Kang, Min-Seong;Song, Seo-Hyeon;Kang, Nam-Hee;Yoo, Na-Young;Kim, Jeong-Eun;Kang, Choong-Won;Kim, Youn-Ho;Seo, Jeong-Hwa;Choi, Ok-Kyung;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.243-251
    • /
    • 2020
  • In this study, we investigated pesticide residues in 207 agricultural products distributed by direct trade in the northern area of Gyeonggi Province. A total of 94 general agricultural products and 113 eco-friendly agricultural products collected from local grocers and cooperative stores were analyzed by multiresidue method for 263 pesticides using GC (gas chromatography)/ECD (electron capture detector), GC/NPD (nitrogen phosphorus detector), GC-MS/MS (tandem mass spectrometry), LC (liquid chromatography)/PDA (photodiode array detector), LC/FLD (fluorescence detector), LC-MS/MS. All samples showing pesticide residues were general agricultural products collected from local food stores. The pesticide residue levels of 14 samples (6.8%) were below the maximum residue limits (MRLs) and one of them (0.5%) exceeded the MRLs. Sixteen pesticides were detected from samples of the following produce items: spinach, young cabbage, perilla leaves, mallow, cucumber, chives and water dropwort. The safety of the detected pesticides was assessed by monitoring the daily intake estimate (EDI) and the daily intake allowance (ADI) based on the amount of pesticides detected. The ADI percentage range (the ratio of EDI to ADI) was 0.0134-61.6259% and there was no health risk connected with consuming agricultural products in which pesticide residues were detected.

Monitoring of Pesticide Residues and Risk Assessment for Medicinal Plants (국내 유통 약용식물 중 잔류농약 모니터링 및 위해성 평가)

  • Ahn, Ji-Woon;Jeon, Young-Hwan;Hwang, Jeong-In;Kim, Jeong-Min;Seok, Da-Rong;Lee, Eun-Hyang;Lee, Sung-Eun;Chung, Duck-Hwa;Kim, Jang-Eok
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.13-18
    • /
    • 2013
  • This study was conducted to monitor residual pesticides in ginseng and balloon flower roots and to assess their risk to human health. All of 112 samples consisted of ginseng and balloon roots were purchased from traditional domestic markets and supermarkets in nine provinces of Korea in 2012. Multi-residue analysis of 122 pesticides was conducted and the analysis was performed by gas chromatography-electron capture detector, gas chromatography- nitrogen/phosphorus detector, and high-performance liquid chromatography. Seven pesticides were detected in 12 root samples and the detection rate was 10.7%. The detected twelve root samples were 10 ginseng root samples and 2 balloon root samples. Pesticides detected in root samples were procymidone, kresoxim-methyl, endosulfan, cypermethrin, tralomethrin, tetraconazole and chlorfluazuron. Among them, two pesticides as tetraconazole in a balloon flower root and cypermethrin in a ginseng root exceeded the recommended maximum residue limit set by Korea Food and Drug Administration. Five pesticides detected from 10 root samples were identified as unregistered pesticides in Korea. In order to do risk assessment with Korean medicinal plant consumption, estimated daily intake of residual pesticides were determined and compared to acceptable daily intake, referring to %ADI values. The range of %ADI values was from 0.006% to 0.333%. Taken together, it demonstrates the pesticides found in the two root samples were below the safety margin, indicating no effect on human health.

Simultaneous Determination of Pesticide Residues in Soils by Dichloromethane Partition - Adsorption Chromatography - GC-ECD/NPD Analytical Methods (Dichloromethane 분배 - 흡착 크로마토그래피 - GC-ECD/NPD 분석법에 의한 토양잔류농약 다성분 분석)

  • Kim, Chan-Sub;Lee, Byung-Moo;Park, Kyung-Hun;Park, Byung-Jun;Park, Jae-Eup;Lee, Young-Deuk
    • The Korean Journal of Pesticide Science
    • /
    • v.14 no.4
    • /
    • pp.361-370
    • /
    • 2010
  • Considering the efficiencies of the preparation process at each stage obtained in previous studies, the analytical determination method was established for multi-pesticide residues in soils. It consist of the acetone-extraction, the dichloromethane-partition, the Florisil or silica-gel chromatography and the gas chromatography analysis equipped with the electron capture detector and the nitrogen-phosphorus detector. In the soil recovery test by Florisil clean-up system, the number of pesticides recovered in the range of 70~120% and showed less than 20% of RSD were 165 pesticides for paddy soil, 169 pesticides for upland soil and 159 pesticides in both soils through the tested 183 pesticides. And in the soil recovery test by silica-gel system, the number of pesticides recovered in the range of 70~120% and showed less than 20% of RSD were 154 pesticides for paddy soil, 145 pesticides for upland soil, and 134 pesticides in both soils.