• Title/Summary/Keyword: Electromagnetic therapy

Search Result 74, Processing Time 0.024 seconds

Development of stimulator for peripheral disturbance therapy using A variable Micro-electromagnetic (미약 전자기장을 이용한 말초장애 치료시스템 개발)

  • Kim, Soo-Byung;Lee, Seung-Wook;Shim, Ta-Kyu;Lee, Na-Ra;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1209-1216
    • /
    • 2010
  • It has increased that peripheral disturbance(blood flow, nerve, Raynaud's phenomenon) and finger rheumatoid arthritis which is caused by the diabetic complications. To improve these pain issues, we proposed new method for the Finger Disease Therapy(FDT). In this paper, we manufactured solenoid cylindrical coil which was only for the FDT using a variable micro-electromagnetic. Also, we designed the Finger Disease Therapy System(FDTS) which could select three stimulation modes(N_pulse, S_pulse, N/S_pulse) and frequency(0.25hz, 0.5hz, 1hz). We used a Teslameter to measure magnetic flux inner solenoid, and measured magnetic flux as distance(0 ~ 3cm) inner solenoid with stimulation modes and frequency. In the results, magnetic flux was the highest in center of solenoid(0cm) for all stimulation modes. Also, the highest magnetic flux was measured as N_pulse(294.3mT), S_pulse(293.8mT) in 1Hz and N/S_pulse (275.4mT) in 0.25Hz, respectively. Therefore, we developed the FDTS using various pattern and intensity for finger diseases therapy, and checked therapy clinic application possibility of the FDTS as measuring magnetic flux inner solenoid.

Safety of Electromagnetic Field Made by Intelligent Thermo-Acupuncture System (지능형온침자극기의 전자기장 측면의 안전성)

  • Yuk, Geun-Yeong;Lee, Seung-Ho;Kim, Young-Kon;Lim, Sa-Bi-Na
    • Korean Journal of Acupuncture
    • /
    • v.24 no.4
    • /
    • pp.69-84
    • /
    • 2007
  • Objectives : Intelligent thermo-acupuncture system (ITA-system) is invented for the convenient operation of thermo-acupuncture therapy. The aim of this study is to investigate the safety of 100 ㎑ electromagnetic field (EMF) made by ITA-system. Methods : We analysed the influence of this EMF on animals. In order to do experiment in the influence of EMF, male ICR mice were exposed to EMF at different distances from the ITA-system. And we examined weight, diet, behavior, organ and hematological changes. Results & Conclusions : According to the animal studies with mice about EMF influence, there was no significant difference between the control group and the exposed groups about them. In conclusion, the safety of 100 ㎑ EMF made from ITA-system through this animal research was checked.

  • PDF

Enhancement of Mixing Performance in Viscous Liquid Using an Electromagnetically Driven Microrobot (초소형 로봇을 이용한 점도성 유체의 혼합 효율 향상)

  • Song, Hyeonseok;Park, Yuna;Chung, Sang Kug
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.2
    • /
    • pp.53-58
    • /
    • 2018
  • This paper presents an electromagnetically driven microrobot for the enhancement of mixing performance in high viscous liquid media such as blood and bone marrow. First, an electromagnetic system was fabricated, and the magnetic flux density generated from the system was compared with the theoretical value. Second, the reciprocating motion of the microrobot was demonstrated in microchannel using electromagnetic system. As a proof of concept, the mixing performance by the electromagnetically driven microrobot in high viscous liquid was investigated using safranin solution. As a result, it was completely mixed within 140 s with the reciprocating motion of the microrobot while it took 1680 s for natural diffusion. In addition, the mixing efficiency was quantitatively evaluated through a mixing index obtained by an image analysis. The proposed method provides not only wireless actuation of a microrobot with a simple design but also high mixing performance in variety of high viscous liquid media.

Effectiveness of Iliopsoas Self-Stretching on Hip Extension Angle, Gluteus Maximus Activity, and Pelvic Compensations during Prone Hip Extension in Subjects with Iliopsoas Shortness

  • Kim, Ki-Song;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.1
    • /
    • pp.23-28
    • /
    • 2018
  • Purpose: This study examined the effectiveness of iliopsoas self-stretching on the hip extension angle, gluteus maximus (GM) activity, and pelvic compensated angle during prone hip extension (PHE) in subjects with iliopsoas shortness. Methods: Twenty-healthy subjects with iliopsoas shortness were recruited. Electromyography (EMG) was used to examine erector spinae (ES), multifidus (MF), GM, and biceps femoris (BF) while performing PHE. An electromagnetic tracking motion analysis device was used to measure the pelvic compensations. The pelvic compensations while performing PHE were considered to be anterior tilting and rotation. A modified Thomas test was used to monitor the hip extension angle before and after iliopsoas self-stretching. A paired t-test was used to investigate the significant difference after iliopsoas self-stretching during PHE. The level of statistical significance was set to ${\alpha}=0.05$. Results: Muscle activity of GM and hip extension angle were significantly greater after iliopsoas self-stretching compared to that before iliopsoas self-stretching during PHE (p<0.05). BF and pelvic rotation angle were significantly lower after iliopsoas self-stretching compared to that before iliopsoas self-stretching during PHE (p<0.05). The muscle activity of ES was not significantly different between PHE before and after iliopsoas self-stretching (p>0.05). Conclusion: Iliopsoas self-stretching can be effective in selectively strengthening the GM muscles with minimized pelvic compensation in subjects with iliopsoas shortness.

An Electromagnetic Shock Wave Generator Employing a Solenoid Coil for Extracorporeal Shock Wave Therapy: Construction and Acoustical Properties (체외 충격파 치료술을 위한 솔레노이드 코일을 이용한 전자기식 충격파 발생기: 구성 및 음향학적 특성)

  • Choi Min Joo;Lee Jong Soo;Kang Gwan Suk;Paeng Dong Guk;Lee Yoon Joon;Cho Chu Hyun;Rim Geun Hie
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.5
    • /
    • pp.271-281
    • /
    • 2005
  • An electromagnetic type shock wave generator suitable for extracorporeal shock wave therapy has been constructed by employing a solenoid coil. The Property of the shock waves produced by the shock wave generator was evaluated using a needle hydrophone. It was shown that, as the capacitor discharging voltage increased from 8 to 18 kV, the Positive Peak Pressure (P+) of the shock wave increased non-linearly from 10 to 77 Wa. In contrast. the negative peak Pressure (f) varied between -3.2 and -6.8 MPa. had its absolute maximum of -6.9 ma at 14 kV The peak amplitudes P+ measured repeatedly under the same voltage setting varied within $5\;\%$ from mean values and this is very small compared to about $50\;\%$ for electrohydraulic type shock wave generators. It could be observed, from the hydrophone signal recorded over 1 ms. several sequential acoustic impulses representing bubble collapses. namely. acoustic cavitation. induced by the shock wave. A technique based on wavelet transformation was used to accurately measure the time delay between the 1st and 2nd collapse known to be closely related to the shock strength. It was observed that the measured time delay increased almost linearly from 120 to $700\;{\mu}s$ with the shock wave Pressure P+ increasing from 10 to 77 MPa.

Lightening up Light Therapy: Activation of Retrograde Signaling Pathway by Photobiomodulation

  • Kim, Hong Pyo
    • Biomolecules & Therapeutics
    • /
    • v.22 no.6
    • /
    • pp.491-496
    • /
    • 2014
  • Photobiomodulation utilizes monochromatic (or quasimonochromatic) light in the electromagnetic region of 600~1000 nm for the treatment of soft tissues in a nondestructive and nonthermal mode. It is conceivable that photobiomodulation is based upon the ability of the light to alter cell metabolism as it is absorbed by general hemoproteins and cytochrome c oxidase (COX) in particular. Recently it has been suggested radiation of visible and infrared (IR) activates retrograde signaling pathway from mitochondria to nucleus. In this review, the role of COX in the photobiomodulation will be discussed. Further a possible role of water as a photoreceptor will be suggested.

Analysis of Hematoporphyrin Derivative by Design and Manufacture of High Resolution Charge Coupled Device in Spectrometry (분광기에 고 분해능 Charge Coupled Device의 설계 및 제작에 의한 Hematoporphyrin Derivative의 분석)

  • Kim, Ki-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.77-83
    • /
    • 2005
  • The influence of fluorescence, scattering, and absorbance in turbid material by light scattering was interpreted by the scattered fluorescence intensity and wavelength. The effect of optical property in scattering media was investigated. It is very important to study the charge coupled device(CCD) in spectrometry because we can use the molecular energy level, molecular structure, absorption or emission, intermolecular reaction, weakly bound molecular energy, photochemistry, fluorescence and photodynamic therapy. CCD is very essential to study the molecular structure and medical engineering combined laser spectroscopy in the modem physical and chemistry. Accordingly, this study has designed and manufactured the electromagnetic spectrometry with CCD, and has analyzed the hematoporphyrin derivative.

Activation and Onset Time of the Gluteus Maximus Muscle during Three Different Prone Table Hip Extension Exercises

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.5
    • /
    • pp.295-301
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the electromyographic activity and onset time of the gluteus maximus (GM) and hamstring (HAM), lumbopelvic kinematics during three different prone table hip extension exercises in healthy individuals. Methods: Twenty subjects were participated. Electromyography device was used to measure the muscle activities and onset time of the GM and HAM muscles. An electromagnetic tracking motion device was used to measure lumbopelvic compensations. The subjects were asked to perform three different prone table hip extension [Prone table hip extension with the abdominal drawing-in maneuver on a chair (PTHEA), PTHEA with the ipsilateral knee flexion (PTHEAF), PTHEAF with hip 30 abduction (PTHEAFA)]. One-way repeated measures analysis of the variance and a Bonferroni post hoc test were used. Results: The electromyographic activity and onset time were significantly different among three conditions (PTHEA vs. PTHEAF vs. PTHEAFA)(p<0.01). The GM muscle activity and onset time were significantly greater and reduced during the PTHEAFA compared to PTHEA and PTHEAF (p<0.01). However, The HAM muscle activity and onset time were significantly smaller and delayed during the PTHEAFA compared to PTHEA and PTHEAF (p<0.01). Conclusions: PTHEAFA exercise can be recommended to facilitate the muscle activity and efficient muscle firing time of GM without HAM dominance.

Biophysical therapy and biostimulation in unfavorable bony circumstances: adjunctive therapies for osseointegration

  • Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.4
    • /
    • pp.195-203
    • /
    • 2012
  • Dental implants using titanium have greatly advanced through the improvement of designs and surface treatments. Nonetheless, the anatomical limits and physiological changes of the patient are still regarded as obstacles in increasing the success rate of implants further, even with the enhancement of implant products. So there have been many efforts to overcome these limits. The intrinsic potential for bone regeneration can be stimulated through adjuvant treatments with the continuous improvement of implant properties, and this can play an important role in achieving optimum osseointegration toward peripheral bone tissue and securing ultimate long-term implant stability in standard surgical procedures. For this purpose, various chemical, biological, or biophysical measures were developed such as bone grafts, materials, pharmacological agents, growth factors, and bone formation proteins. The biophysical stimulation of bone union includes non-invasive and safe methods. In the beginning, it was developed as a method to enhance the healing of fractures, but later evolved into Pulsed Electromagnetic Field, Low-Intensity Pulsed Ultrasound, and Low-Level Laser Therapy. Their beneficial effects were confirmed in many studies. This study sought to examine bone-implant union and its latest trend as well as the biophysical stimulation method to enhance the union. In particular, this study suggested the enhancement of the function of cells and tissues under a disadvantageous bone metabolism environment through such adjunctive stimulation. This study is expected to serve as a treatment guideline for implant-bone union under unfavorable circumstances caused by systemic diseases hampering bone metabolism or the host environment.