• Title/Summary/Keyword: Electromagnetic standard

Search Result 365, Processing Time 0.03 seconds

A Study on the Evaluation Method of Lap Shear Strength for Induction Welding of Thermoplastic Composites using Tensile Test (인장 시험을 이용한 열가소성 복합재료 유도용접 전단강도 평가방법에 대한 고찰)

  • Baek, Inseok;Lee, Seoksoon
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2022
  • Currently, Induction welding is attracting attention as a non-contact, clean and fast welding process. However, since thermoplastic resins are not affected by electromagnetic fields, induction welding requires a heating element called a susceptor. Researches are being conducted with the aim of achieving high-quality bonding, however, the factor of a heating element is an issue, hence the need to set a standard. Specimen fabrication and testing are conducted according to ASTM D5868. In this study, we propose that the evaluation criteria be judged on the basis of three factors; the condition of the welded joint surface, void content, and lap shear strength. Since the adhesive surface to be welded melts and solidifies as it cools, rapid temperature changes can generate pores. In addition, if the heating is not uniform, it is difficult to expect the desire performance. Using PA6 (CF 30%) thermoplastic, susceptor fabrication, induction welding and performance verification were conducted.

A Study on the Standard of Number of Verticals in the Discharge Measurements using Electromagnetic Wave Surface Velocimeter (전자파표면유속계를 이용한 유량측정시 측선수 기준에 관한 연구)

  • Song, Jae Hyun;Lee, Ki Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.253-253
    • /
    • 2022
  • 수문조사 방법 및 기준은 각 국가별 기후, 유역 및 하천특성에 따라 다르게 제시되고 있으며, 세계기상기구(WMO)나 국제표준화기구(ISO)에서는 국제적으로 통용될 수 있는 기준을 제시하고 있다. 대부분의 국가에서는 국제기구 또는 수문조사 선진국(미국, 일본, 영국 등)에서 제시한 기준 및 방법을 도입하여 적용하고 있으며, 국내의 경우도 국제기준과 더불어 미국의 기준과 우리나라와 기후, 지형 및 하천특성이 비슷한 일본의 기준을 많은 부분에서 도입하였다. 유속계에 의한 유량측정 시 측선수를 늘리면 정확도를 높일 수 있지만 대하천 또는 수위(유속)가 급변하는 경우에는 측선수를 많이 해서 측정시간이 길어지면 오히려 정확도를 떨어뜨릴 수 있다. 특히, 국내에서 홍수시 신속한 측정에 사용되는 부자와 전자파표면유속계는 기존의 회전식유속계 측선수 기준을 적용하는 것은 적합하지 않다. 이에 따라, 우리나라 수문조사 전담기관인 한국수자원조사기술원에서는 전자파표면유속계 측선수 기준을 실무적으로 제시하고 있으나 이에 대한 기술적인 검토가 부족한 실정이다. 본 연구에서는 2016년~2020년까지 한국수자원조사기술원에서 측정된 58개 지점의 총 739개의 전자파표면유속계 측정성과에 대하여 수면폭 및 측선수 현황을 살펴보았다. 한국수자원조사기술원 일반기준 이상 측선수 비율은 646개(87.4%), 긴급기준 이상 측선수 비율은 739개(100.0%) 그리고 전체 평균값 이상 측선수 비율은 404개(54.7%)로 나타났다. 일반기준 이상 측선수가 많은 원인을 파악해보기 위하여 측선수를 최대구간유량비 20% 이상일 때까지 측선수를 10%씩 감소하여 산정된 유량의 변화를 검토하였다. 유량 변화 검토 결과 현장에서 유량측정 시 측선수의 등유량 배치, 최대구간유량비(20%) 및 불확도(±10%) 기준을 준수하기 위해서 기준 이상의 측선수를 확보하는 경향으로 판단되었다. 이러한 문제를 해소하기 위하여 측선수 감소에 따른 유량 편차율 ±10%와 불확도 ±10% 조건을 만족하는 수면폭 구간별 최소 기준을 제시하였으며, 이 기준을 적용할 경우 전자파표면유속계로 현장에서 보다 신속하고 정확한 유량측정을 수행할 수 있을 것으로 기대된다.

  • PDF

Electrical Resistivity-Measurements for the Detection of Fracture Zones in the Woraksan Granitic-Bodies (월악산화강암체의 파쇄대규명을 위한 전기비저항탐사)

  • 김지수;권일룡
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.113-126
    • /
    • 1997
  • Electrical resistivity methods of dipole - dipole array profiling and Schiumberger array sounding were tested on a segment of the Woraksan granitic batholith for the research into the imaging of irregular attitudes of fracture zones in the crystaaline rock in terms of processing and interpretation schemes. By the dipole - dipole array method, inhomogeneities such as small scale of fracture zones were properly delineated down at some depth even within hard rock environment. Fracture zones were interpreted to be at the boundaries between the high amplitude zone and very low amplitude zone in the resistivity plot and they were also successfully outlined in two - dimensional layer and pseudo - three - dimensional volume constructed by the incorporation of vertical sounding data. The surface location of the fracture zones was correlated by the zero - crossing point in the VLF(very low frequency) electromagnetic data. Pseudo - three - dimensional attitudes of fracture zones were efficiently illuminated by optimum projection angle. The mean of bulk resistivity for the Woraksan granite and the near fracture zones is estimated to be approximately of 4,000 ohm - m which is much higher than the value of 700 ohm - m for the Rwachunri limesilicate environment. This difference is due to both the rock type, i.e., biotite granite vs limesilicate, and the occurrence of secondary openings of fold and fault associated with the intrusion of granite. In this study statistical analyses on the resistivity color plot were performed in terms of three representative statistical moments, i.e., standard deviation, skewness, and kurtosis. The fracture zones in the standard deviation plot were characterized by the higher value, compared to the value of homogeneous portion. The upper boundary of the high resistivity zone was also successfully delineated in the skewness and kurtosis plots.

  • PDF

Analysis of Radio Propagation Environment in Busan Area for DTV Service (디지털 TV서비스를 위한 부산지역 전파환경 분석)

  • Sung Tae-Kyung;Weon Young-Su;Cho Hyung-Rae;Kim Ki-Moon
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.869-874
    • /
    • 2004
  • Digital TV broadcasting's resolution or tone quality is very excellent than analog broadcasting and has many advantages including various multimedia functions such as home shopping, home banking, internet search, telecommuting, VOD, etc. In this study, it is essential to analyze the regional electromagnetic environment before Digital TV broadcasting, and therefore we analyzed Busan area's limitation using ETRI propagation model. For maintaining high-quality Digital TV signals, we measure electric field intensity wide and far in Busan including mountains area and high-rise buildings. Generally, it has lower value by a standard ETRI propagation model than simulated value about standard model, but distribution pattern are similar with it. Compared theoretical values with the measured results, they have similar values for flat area but very different values for crowded city area and mountains area So we conclude that ETRI propagation model and theoretical model are not suitable for Busan in a free space.

16-port Feed Waveguide Array for DBS Reception System Mounted on Vehicle (차량 탑재형 DBS 수신 시스템용 16 포트 급전 도파관 어레이)

  • Min, Gyeong-Sik;Kim, Dong-Cheol
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.2
    • /
    • pp.92-100
    • /
    • 2002
  • The 16-port feed waveguide array with inductive walls analyzed by Galerkin's method of moments are proposed for the DBS reception system mounted on vehicle. First of all, in order to verify the validity of electromagnetic analysis and design for a $\pi$-junction feed waveguide, it is designed and fabricated at DBS band. The measurement results of a $\pi$-junction feed waveguide agree well with the theoretical ones. Based on this design method, an array design for WR-90 standard waveguide is conducted. Since the width of a $\pi$-junction feed WR-90 standard waveguide is larger than a guided wave length in an array design, the difference of amplitude and phase of 8-port array are calculated 2.3 dB and 62 degrees, respectively. The bandwidth with return loss of -20 dB below is about 220 MHz and it doesn't satisfy DBS band. To solve this problem, we propose a novel design that the width of a $\pi$-junction feed waveguide equals to a guided wave length. By the proposed novel design for 8-port feed waveguide array, the difference of amplitude and phase are decreased 1 dB and 13 degrees, respectively. The broad bandwidth of 700 MHz is also realized. The size of 16-port waveguide away compared with WR-90 array is reduced about 10 cm. The measured antenna gain for the fabricated 16-port feed waveguide array is observed 24 dBi above at DBS band.

A study on the EMI in special power distribution zone on ship (선내 특별 전원 분배구역의 EMI에 관한 연구)

  • Park, Jong-Sung;Choi, Gi-Do;Kim, Jong-Woo;Cho, Hyung-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.730-736
    • /
    • 2014
  • Test standards for electrical and electronic equipment required for ship operations is applying the IEC-60533 standard. However, although a test procedure and a specified regulation are clearly defined in the deck and bridge zone and general power distribution zone, they are not regulated in the special power distribution zone with ship propulsion system. For these reasons, the costs for additional research and development have been invested. In this paper, we was measured power noise in a special power distribution zone in ship and we were compared and analyzed values measured. The actual experiments are performed on the ship of Korea Maritime and Ocean University. As a result, the acquired data on Hanbada shows that loop antenna with low frequency band(160kHz) and ultra log antenna with high frequency band(1.97GHz)occur about 6-8dB differences and about 8.7 difference respectively. Also, the acquired data on Hannara shows that each loop antenna of 1MHz, 11MHz, and 25MHz occurs about 7dB difference about 4-5dB differences respectively. so standard of Special distribution zone must be specified by comparative analysis of data obtained by the experiment more.

An Investigation on the self-consciousness Symptoms of the Clerical Workers attendant upon Office Automation (사무 자동화에 따른 사무직 근로자의 건강과 연관된 자각 증상에 대한 조사연구)

  • Jung, Mi Wha
    • Korean Journal of Occupational Health Nursing
    • /
    • v.3
    • /
    • pp.54-70
    • /
    • 1993
  • According as the automation of clerical work(OA ; Office Automation) develops, the use of VDT(Visual or Video Display Terminal) is increasing suddenly. But, in proportion to the spread of office automation(OA tendency), the self-conciousness syptom attendant upon the work is appearing also (Kim, Jung Tae, Lee, Young Ook, 1990). The apparatuses of office enable the clerical workers to be convenient and perform mass businesses. But, they are increasing the opportunity to be exposed to VDT syndrom, techno stress, computer terminal disease, pain by muscle strain(RSI), bradycausia of noise nature, and electromagnetic waves, etc. which are referred to as the new type of occupational diseases to the workers. It is the real situation that the workers to use VDT is complaining of the physical inconvenience sense in the recent newspaper and literature, it is the point of time that the sydrome to come from VDT use and computer terminal disease, etc. must be classified into the occupational disease(Lee, Kwang Young 1990, Lee, Kyoo Hak 1990, Lee, Won Ho 1991, Lee, Si Young 1991, Lee, Joon 1991, Choi, Young Tae 1991, Heo, Seung Ho 1989). In addition, it is the real situation that the scientifitic study result about the scope that electromagnetic waves has influence on the human body has not been suggested yet, and criticism on the stable exposure permission standard about electromagnetic waves to be emitted from VDT and on the problem in the health about electromagnetic waves is continuing. (IEEE Spectrum, 1990). In addition according to the experience of nursery business of industry field, it is the real situation that the patients who consult complaining of physical and mental inconvenience sence, among the users of apparatus of office automation, are reaching 10% of the patients coming to doctor's room. Therefore, it is necessary to confirm the self-consciousness symptom that the clerical workers complain of multilaterally with the actual state examination about the use of the apparatuses of offices automaton. Thus, this study was tried as th basic data for the cosultation and education for the maintenance and furtherance of the health of workers as the nurse of industry field, by confirming the contents of self-consciousness symptom attendant upon the use of the apparatus for office outomation making the financial institution in which the spparatus for office automation in most frequently used as the subject, and by examining whether there is the difference according to the subject of study, the data were collected, by using the questionnaire method, making 200 workers who consented to the study participation as the subject, among the persons who have spent over 3 months since they used the apparatuses for office automation and didn't receive the treatment in hospital due to the clerical disease for recent 3 years. The period of data collection was from Oct. 9, 1991 to Oct. 12. As for the measurement instrument about the complaint if self-consciousness symptom attendant upon the use of apparatuses fo office automation, the question item on the complaint symptom of health problem attendant upon the treatment of VDT that Kim(1991) developed and on CMI health problem and the question items on the fatigue degree due to industry were used by previous examination to 25 persons. Collected data were analyzed with the statistical method such as percentage, arithmetic mean, Person correlation coeffient, Kai square verfication, t-test, ANOVA, etc. by using SPSS/PC+ program, and the result is as follows : 1. The self-consciousness symptom that the clerical workers complained of most frequetly appeared high in 'My eyes are tired'(99.4%), 'I feel fatigue and weariness'(99.4%), 'I feel that my head is heavy5(90.0%), 'eyesight fell'(88.8%), 'I have a stiff neck'(88.8%), 'I fell pain in the shoulder'(85.0%), 'I feel cold and painful in the eyes'(76.9%), 'I feel the dry sense of eyeball'(76.2%), 'My nerves are edgy, and I an fretful, (75.6%), 'I feel pain in the waist'(73.2%) and 'I fell pain in the back'(72.8%). It emerged that the subject use the apparatuses for office automation complained of self-consciousness symptoms related to visual symptoms and musculoskeletal symptoms. 2. As for the general feature of examination subjects, the result to see the distribution by classifying into sex, age, school career, use career of apparatuses for office automation, skillfulness degree of the use of apparatus for office automation, use hours of the apparatuses for office automation per 1 day, type of business of the apparatus for office automation, rest hours during the use of apparatus for office automation, satifaction degree of business of office automation, and work circumstance, etc. emerged as follows : As for the sex of subjects, the distribution showed that men were 58.8% and women were 41.3%, Age was average 26.9. As the distribution of school career, the distribution showed that4below the graduation of high school' was 58.8%, 'graduation from junior college-university' was 35.0%, and 'over graduate school' was 6.3%. In the question to ask the existence or non-existence of experience of health consultation in connection with the work of office automation, the response that I had the consultation exprience and I feel the necessity emergerd as 90.1% And, the case that the subject who didn't wear the glasses or lens before using the OA apparatus wear glasses or lens after using OA apparatus emerged as 28.3% of whole. As for the existence or non-existence of use career of OA apparatus, the case under 3 years was highest as 52. 7%. As for the skillfulnness degree about the use of apparatus for office automation, most of them are skillful with the fact that 'common' was 44.4%, 'skill' was 42.5%, and 'unskillful' was 13.1% As for the use average hours of the apparatus for office automation per 1 day, the distribution showed that the case under 3-6 hours was 33.1%, the case under 6-9 hours was 28.1%, the case under 3 hours was 30.6%, and the case over 9 hours was 8.1% Main OA business and the use hours for 1 day showed in the order of keeping and retrieval, business of information transmission(162min), business of information transmission(79.3 min), business of document framing(55.5 min), and business of duplication and printing(25.4min). as for the rest during the use of apparatus for affice automation, that I take rest occasion demands the major portion, but that I take after completing the work emerged as 33.8%. Though the subiness gets to be convenient by the use of the apparatus for of office automation, respondents who showed the dissatisfaction about the present OA business emergd high as 78.1%. The work circumstances of each office was good with the fact that the temperature of office was 21.8, noise was average 42.7db, and the illumination was average 364.4 lx, in the light of ANSi/HFS 100 Standard. 3. Sight syptom, musculoskeletal symptom, skin and other symptoms showed the significant difference according to the extent of skillfulness of the apparatus for office automation. All the symptoms exept skin symptom showed the difference according to the use hours of the apparatus for office automation. All the question items exept the sytoms of digestive organs and the rest hours during the apparatus for office automation showed the signicant difference. The question item which showed the signicant difference from the satisfaction degree of present OA business showed the significant difference from all the question item classified into 6 groups. But, age and school career didn't significant difference from the complaint of any self-consciousness symptoms.

    . In conclusion, the self-consciousness symptoms of the subjects to use OA apparatus appeared differently, according to sex distiction, skillfull degree of OA apparatus, use hours of OA apparatus, the rest hours during th use of OA apparatus, and the satiafaction degree of persent business. Therefore, it is necessary that the nurse in the inuctry field must recognize to receive the education about the human technological physical condition which is most proper for te use of OA apparatus and about the proper rest method until they get accustomed to the use of OA apparatus. In addition, the simple exercise relax the tention of muscle due to the repetitive simple movement, and the education for the protection of eyesight are necessary.

  • PDF
  • The Study on Risk Factors Analysis and Improvement of VDT Syndrome in Nuclear Medicine (핵의학과 Video Display Terminals Syndrome 유해 요인 조사 및 개선에 관한 연구)

    • Kim, Jung-Soo;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo;Han, In-Im;Joo, Yung-Soo
      • The Korean Journal of Nuclear Medicine Technology
      • /
      • v.14 no.1
      • /
      • pp.61-66
      • /
      • 2010
    • Purpose: Recently, Department of Nuclear Medicine have an interest in Video Display Terminals (VDT) syndrome including musculoskeletal disorders, ophthalmologic disorders, trouble of electromagnetic waves and stress disorders occur to VDT workers as the growing number of users and rapid pace of service period supply in large amount. This study research on the actual condition for VDT syndrome in Nuclear Medicine, Seoul National University Hospital (SNUH), discover the problem and draw a plan of upcoming improvement. The aim of this study establish awareness about VDT syndrome and is to prevent for it in the long run. Materials and Methods: Department of Nuclear Medicine, SNUH is composed Principle part, Pediatric part and PET center. We estimated risk factors visit in each part directly. Estimation method use "Check list for VDT work" of Wonjin working environment health laboratory and check list is condition of VDT work, condition of work tables, condition of chairs, condition of keyboards, condition of monitors, working position, character of health management and other working environment. Analysis result is verified in Department of Occupational and Environment, Hallym University Sacred Heard Hospital. Results: As a result of analysis, VDT condition of Department of Nuclear Medicine, SNUH is rule good. In case of work tables, recent of things are suitable to users upon the ergonomical planning, but 15% of existing work tables are below the standard value. In case of chairs are suitable, but 5% of theirs lost optimum capacity become superannuated. The keyboards are suitable for 98% of standard value. In case of monitors, angle control of screen is possible of all, but positioning control is impossible for 38%. In case of working position, 10% is fixed positioning for long time and some of the items researched unsuitable things for standard. At health management point, needed capable of improvement. Also, other working condition as lighting, temperature, noise and ventilation, discovered the problem, but is sufficient to advice value. Conclusion: VDT syndrome is occurrences of possibility continuously, come economical expensive about improvement, is inherent in various causes and originate without your knowledge. So, there is need systematic management system. In Nuclear Medicine, VDT syndrome make it better that constant interest and effort as improvement of ergonomical working environment, improvement of working procedure, regular exercise and steady stretching, and can be prevented fairly. This promote physical and mental condition of worker in top form in comfortable working environment, so this is judged by enlargement of operations efficiency and rising of satisfaction ratings of the inside client.

    • PDF

    60 GHz CMOS SoC for Millimeter Wave WPAN Applications (차세대 밀리미터파 대역 WPAN용 60 GHz CMOS SoC)

    • Lee, Jae-Jin;Jung, Dong-Yun;Oh, Inn-Yeal;Park, Chul-Soon
      • The Journal of Korean Institute of Electromagnetic Engineering and Science
      • /
      • v.21 no.6
      • /
      • pp.670-680
      • /
      • 2010
    • A low power single-chip CMOS receiver for 60 GHz mobile application are proposed in this paper. The single-chip receiver consists of a 4-stage current re-use LNA with under 4 dB NF, Cgs compensating resistive mixer with -9.4 dB conversion gain, Ka-band low phase noise VCO with -113 dBc/Hz phase noise at 1 MHz offset from 26.89 GHz, high-suppression frequency doubler with -0.45 dB conversion gain, and 2-stage current re-use drive amplifier. The size of the fabricated receiver using a standard 0.13 ${\mu}m$ CMOS technology is 2.67 mm$\times$0.75 mm including probing pads. An RF bandwidth is 6.2 GHz, from 55 to 61.2 GHz and an LO tuning range is 7.14 GHz, from 48.45 GHz to 55.59 GHz. The If bandwidth is 5.25 GHz(4.75~10 GHz) The conversion gain and input P1 dB are -9.5 dB and -12.5 dBm, respectively, at RF frequency of 59 GHz. The proposed single-chip receiver describes very good noise performances and linearity with very low DC power consumption of only 21.9 mW.

    Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band (L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기)

    • Hwang, Ji-Hwan;Kwon, Soon-Gu;Joo, Jeong-Myeong;Oh, Yi-Sok
      • The Journal of Korean Institute of Electromagnetic Engineering and Science
      • /
      • v.22 no.7
      • /
      • pp.711-719
      • /
      • 2011
    • A study of miniaturization of an L-band orthomode transducer(OMT) for field experiments of radar backscatter is presented in this paper. The proposed OMT is not required the additional waveguide taper structures to connect with a standard adaptor by the newly designed junction structure which bases on a waveguide taper. Total length of the OMT for L-band is about 1.2 ${\lambda}_o$(310 mm) and it's a size of 60 % of the existing OMTs. And, to increase the matching and isolation performances of each polarization, two conducting posts are inserted. The bandwidth of 420 MHz and the isolation level of about 40 dB are measured in the operating frequency. The L-band scatterometer consisting of the manufactured OMT, a horn-antenna and network analyzer(Agilent 8753E) was used STCT and 2DTST to analysis the measurement accuracy of radar backscatter. The full-polarimetric RCSs of test-target, 55 cm trihedral corner reflector, measured by the calibrated scatterometer have errors of -0.2 dB and 0.25 dB for vv-/hh-polarization, respectively. The effective isolation level is about 35.8 dB in the operating frequency. Then, the horn-antenna used to measure has the length of 300 mm, the aperture size of $450{\times}450\;mm^2$, and HPBWs of $29.5^{\circ}$ and $36.5^{\circ}$ on the principle E-/H-planes.


    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
    Copyright (C) KISTI. All Rights Reserved.