• Title/Summary/Keyword: Electromagnetic Transient Studies

Search Result 22, Processing Time 0.026 seconds

Z-Domain Frequency Dependent AC System Equivalent for Electromagnetic Transient Studies (전자기 과도 현상 해석을 위한 Z 영역에서의 주파수 의존 교류시스템 등가)

  • Wang, Yong-P.;Hur, Dong-Y.;Park, Hee-C.;Chung, Hyeng-H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.252-255
    • /
    • 2001
  • Modern power systems are very complex and to model them completly is impractical for electromgnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing FDNE is presented and demonstrated. The FDNE is generated by Linearized Least Square fitting the frequency response of a z-domain formulation. The advantage of this approach is that a direct implementation occurs which dose not incur errors due to discretization inherent with implementing a fitting function in the s-domain. The developed FDNE is accurate and efficient.

  • PDF

Modeling and Analysis of the KEPCO UPFC System by EMTDC/PSCAD

  • Yoon, Jong-Su;Kim, Soo-Yeol;Chang, Byung-Hoon;Lim, Seong-Joo;Choo, Jin-Boo
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.3
    • /
    • pp.148-154
    • /
    • 2003
  • This paper describes the development of KEPCO's 80MVA UPFC electromagnetic transient model and the analysis of its performance in the actual Korean power system. KEPCO's 80MVA UPFC is currently undergoing installation and will be ready for commercial operation from the year 2003. In order to apply a new FACTS device such as the UPFC to the actual power system, the utility needs, in advance, both load flow stability studies and transient studies. Therefore, KEPRI, the research institute of KEPCO, developed a detailed transient analysis model that is based on the actual UPFC S/W algorithm and H/W specifications. This simulation model is implemented by an EMTDC/PSCAD package. The results of the simulation show the effectiveness of UPFC operation in the KEPCO power system.

Excitation System Stress in Synchronous Machine Connected to HVDC System (HVDC 단에 연결된 동기기의 여자시스템 스트레스)

  • Kim, Chan-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.8
    • /
    • pp.482-492
    • /
    • 2002
  • This paper deals with overvoltage stresses in the field circuit of synchronous machine connected to HVDC terminal. A load rejection of the HVDC may cause generator in the station to become self-excited, resulting in a severe system overvoltage. This paper shows that violent field current oscillations can be produced by resonance between the machine inductance and the terminal capacitance. As most conventional excitation system do not allow reverses current, new topology of excitation system to allow reverse current is proposed. the proposed system can limit the rate of rise of terminal voltage during conditions of self excitation. Apart from these simulations, the nature(Magnitude and frequency) of the field transient state is explained mathematically. Finally, the EMTDC program is used for the simulation studies.

Transient Characteristics of GIS Grounding Systems by Lightning and Fault (초고압 GIS 접지시스템에서 낙뢰 및 고장에 의한 과도특성 해석)

  • Lee, Hyung-Soo;Shim, Keon-Bo;Kim, Jung-Hoon;Chung, Sang-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.77-79
    • /
    • 1995
  • In performing lightning and fault studies in GISs, it is of great importance to accurately model the conductor network consisting of the grounding systems and overhead conductor structures. In particular, the overhead grounded pipe enclosures of the GIS should be appropriately modelled. In this paper, the overhead pipe enclosures of a 500 kV $SF_6$ breaker and substation grounding system are presented in detail. During a phase-to-ground fault, scalar potentials and electromagnetic fields are computed at different frequencies for various conductor network configurations is defined by varying the number of conductors used to represent the pipes at different frequencies are obtained. Such knowledge will be very useful in reducing computation time for a transient ground potential rise study which will be performed in the future.

  • PDF

Determination of Optimal Controlled Switching Instants for Circuit Breaker of Shunt Reactors (분로 리액터용 개폐제어 차단기의 최적 개폐시점 선정)

  • 이우영;박경엽;정진교;김희진
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.12
    • /
    • pp.664-669
    • /
    • 2002
  • In this paper the method to determine tire optimal switching instants in order to reduce the transient surges during switching not relevant to the neutral treatment of shunt reactors is presented. This method consists of the following two steps. First, the instants of the voltage peaks between the contacts of each poles and the voltage magnitude as well as the moments of the current zero crosses were found out analytically. Next, the instants of the contact touches or separations were determined in consideration of the rate of decrease of dielectric strength or a circuit breaker and the variation of the its operating time. The results obtained from the EMTP(Electromagnetic Transient Program) analysis studies show that the making instants are established at the peak voltage of each three poles for any conditions of a neutral point and the possible upper limited values of inrush currents due to the variation of the mechanical operating time can be estimated.

Adaptive Multi-Tap Equalization for Removing ICI Caused by Transmitter Power Transient in LTE Uplink System (LTE 상향 링크 시스템에서 송신기의 전력 과도 현상에 의해 발생하는 ICI를 제거하기 위한 적응적 멀티 탭 등화 기법)

  • Chae, Hyuk-Jin;Cho, Il-Nam;Kim, Dong-Ku
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.701-713
    • /
    • 2009
  • This paper studies a method for reducing performance degradation due to losing sub-carrier orthogonality caused by power transient between physical channels in LTE uplink transmission. The pattern of inter-carrier interference(ICI) caused by power transient is different from what has been studied for doppler shift, in that its pattern occurs at front and rear sides of channels in each period of power transient. The reason of ICI's occurrence results from power difference between channels, power transient duration, multi-path channel delay spread, and numbers of sub-carrier. New criterion is proposed to find out number of taps of multi-tap equalizer enough to improve the ICI. The scheme is to determine the number of taps of multi-tap equalizer when a normalized interference or a normalized ICI is greater than a normalized noise. Simulation results show that the number of taps is flexibly adjusted according to SNR(Signal to Noise Ratio) of a received signal to improve Bit Error Rate(BER), while the complexity of the proposed scheme is reduced down to 88 percentage of the classical method.

Case Studies for Potential Distribution due to Power Source by Environmental Condition (전원설비에 의한 공간조건별 전위분포 사례 연구)

  • Jung, Jin-Soo;Jung, Jong-Wook;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.50-58
    • /
    • 2011
  • In this paper, potential distribution analysis through the six kinds of case studies examined in the environmental conditions change within a limited space, by the power supply system installed. To interpret the potential distribution using electromagnetic field analysis program and the parameters were state of the ground, the outer wall of the configuration state and the presence of human potential distribution was simulated. Potential distribution analysis, the size of nominal voltage, depending on the impedance of human body to be determined on the impact of surprise decision, but if equipped with appropriate protective equipment can be protected from lightning have been confirmed.

Analysis of Resonant Characteristics in High Voltage Windings of Main Transformer for Railway Vehicle using EMTP (EMTP를 이용한 철도차량용 주변압기 고압권선의 공진특성 분석)

  • Jeong, Ki-Seok;Jang, Dong-Uk;Chung, Jong-Duk
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.436-444
    • /
    • 2016
  • The primary windings of the main transformer for rolling stock have several natural frequencies that can occur internal resonance with transient voltages induced on a high voltage feeding line. Factory testing is limited in its ability to determine whether or not transient voltage with various shape and duration can be excitable. This study presents the design of a high voltage windings model and simulation and analysis of the internal resonant characteristics in terms of the initial voltage distribution and voltage-frequency relationship using the electromagnetic transients program (EMTP). Turn-based lumped-parameters are calculated using the geometry data of the transformer. And, sub-models, being grouped into the total number of layers, are composed using a ladder-network model and implemented by the library function of EMTP. Case studies are used to show the layer-based voltage-frequency relationship characteristics according to the frequency sweep and the voltage escalation and distribution aspects in time-domain simulation.

A Comparison on the Resistance and characteristics of Transient response of Grounding Systems under Surge Currents (서지 전류에 의한 접지계의 과도응답 특성 및 접지저항 비교)

  • Shin, D.H.;Kim, Y.;Jung, Chul-Hee;Cho, Dae-Hoon;Kim, Pil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.222-225
    • /
    • 1999
  • This paper presents the surges response of the grounding systems using frequency domain electromagnetic field analysis software package. The frequency and time domain performance of a building grounding systems subjected to a lighting strike is described and discussed. The computed scalar potentials is presented graphically as a function of spatial coordinates. A double exponential lighting surge current is injected at one corner or the building grounding systems. Time-variant response of rod, mesh and kit grounding systems under impulse currents have been obtained. This paper deals with the results of studies on the time variation of ground resistance in three grounding systems.

  • PDF

A Study on the Protective Coordination of Generator Overexcitation and Overvoltage Relay (발전기 과여자 및 과전압 계전기 보호협조에 관한 연구)

  • Park, Ji-Kyung;Kim, Kwnag-Hyun;Kim, Chul-Hwan;Lyu, Young-Sik;Yang, Jeong-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1187-1194
    • /
    • 2017
  • After North American wide area black out on August 14, 2003, various studies have been conducted to find out the reason of the disaster. One of main reasons was misoperation of generator protection system. Since then, protective coordination between generator protection system and excitation system controls has been hot issue among electrical engineers. Among various generator protection relays, in this paper, we focused on generator overvoltage and overexcitation relay, which protect the over-flux condition of the generator. Thus, at first, we modeled the generator overvoltage, overexcitation relay and detailed power system including excitation system, governor and etc., based on actual field data. And then, we reviewed the protective coordination of generator overvoltage and overexcitation relay using electromagnetic transient program. In addition, we discussed the protective coordination method for redundant protection relays in both automatic voltage regulator and generator side.