• Title/Summary/Keyword: Electromagnetic Imaging

Search Result 196, Processing Time 0.027 seconds

Incoherent Inverse Scattering of 3-Dimensional Underground Cavity in Lossy Medium (손실 매질내에 있는 3차원 지하공동의 Incoherent 역산란)

  • 홍성용;강진섭
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.3
    • /
    • pp.378-391
    • /
    • 1999
  • When the time-harmonic plane wave is incident upon a high-contrast spherical cavity in a lossy medium, the incoherent shadow intensity pattern is acquired by averaging out the multi-frequency intensities of the co-polarized total electric field calculated at the measurement plane perpendicular to the propagating direction of the incident wave in the forward direction. In the spherical rotational measurement configuration, an incoherent imaging of the spherical cavity is obtained via the back-projections of the incoherent shadow intensity pattern. This imaging method is validated by imaging an air sphere in the lossy medium of ${\epsilon}_r$ = 2 and $\sigma$ = 0.001, 0.003 S/m and the conditions for obtaining better images are investigated.

  • PDF

Non-Invasive in vivo Loss Tangent Imaging: Thermal Sensitivity Estimation at the Larmor Frequency

  • Choi, Narae;Kim, Min-Oh;Shin, Jaewook;Lee, Joonsung;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.1
    • /
    • pp.36-43
    • /
    • 2016
  • Visualization of the tissue loss tangent property can provide distinct contrast and offer new information related to tissue electrical properties. A method for non-invasive imaging of the electrical loss tangent of tissue using magnetic resonance imaging (MRI) was demonstrated, and the effect of loss tangent was observed through simulations assuming a hyperthermia procedure. For measurement of tissue loss tangent, radiofrequency field maps ($B_1{^+}$ complex map) were acquired using a double-angle actual flip angle imaging MRI sequence. The conductivity and permittivity were estimated from the complex valued $B_1{^+}$ map using Helmholtz equations. Phantom and ex-vivo experiments were then performed. Electromagnetic simulations of hyperthermia were carried out for observation of temperature elevation with respect to loss tangent. Non-invasive imaging of tissue loss tangent via complex valued $B_1{^+}$ mapping using MRI was successfully conducted. Simulation results indicated that loss tangent is a dominant factor in temperature elevation in the high frequency range during hyperthermia. Knowledge of the tissue loss tangent value can be a useful marker for thermotherapy applications.

A Study on Block Processing Approach for Mono-Static Terrain Imaging Radar (모노스태틱 지형 영상 레이더의 블록 처리 기법 연구)

  • Ha, Jong-Soo;Cho, Byung-Lae;Lee, Jung-Soo;Park, Gyu-Churl;Sun, Sun-Gu;Kang, Tae-Ha
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.549-557
    • /
    • 2013
  • This paper describes a block processing approach to detect targets in front of mono-static terrain imaging radar (TIR). It is difficult to employ several conventional imaging methods of the synthetic aperture radar(SAR) because the TIR is an ultra-wide-band(UWB) type of radar and employs a dechirp-on-receive process. To design an available imaging method, a block processing approach which conducts a range compression and an azimuth compression is proposed in this paper. The complete derivation of the proposed approach is presented. The results of simulations and field tests are demonstrated to show the performance and validity of the proposed approach.

Imaging Method in Time Domain for Bistatic Forward-Looking Radar in Short Range Application (근거리 Bistatic 전방 관측 레이다의 시간 영역 영상화 기법)

  • Sun, Sun-Gu;Cho, Byung-Lae;Lee, Jung-Soo;Park, Gyu-Churl;Ha, Jong-Soo;Han, Seung-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.11
    • /
    • pp.1054-1062
    • /
    • 2011
  • This study describes the time domain imaging algorithm which can be well applied to short-range UWB(ultra wideband) bistatic radar. In the imaging method of SAR technology, the frequency domain method is well applied to the areas which satisfy far-field condition. However in the near-field environment, the image quality is not good due to phase error. However back-projection method based on time domain is well applied to short-range imaging radar. Meanwhile because its processing time is very long, real time-processing is very difficult. To resolve this problem FFBP(Fast Factorized Back-Projection) was proposed. Using the raw data gathered on field we implemented back-projection and FFBP method. Then image quality and processing time were analyzed using these methods.

Imaging Method Using Isorange-IsoDoppler Contours Map in Bistatic Radar (바이스태틱 레이더에서 아이소레인지-아이소도플러 컨투어 맵을 이용한 이미징 기법)

  • Youn, Jae-Hyuk;Chung, Yong-Seek;Chung, Won-Zoo;Jeong, Myung-Deuk;Yang, Hoon-Gee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.255-258
    • /
    • 2014
  • Imaging in bistatic radar has been known a more difficult task than that in monostatic radar. It is because the behavior of the bistatic range and the bistatic Doppler due to the motion of a transmitter and a receiver is so random that the compensation procedure, which we call an imaging algorithm, is quite complicated. This paper presents a bistatic radar imaging algorithm that can be used in some specific bistatic radar geometry. We show this geometry can present rectangular-like resolution cell on isorange-isoDoppler contours map. We also present the associated resolution and simulation results.

Development of Infrared Target for Dual-Sensor Imaging Seeker's Test and Evaluation in HILS System (이종센서 영상탐색기 시험평가를 위한 적외선 표적원 개발)

  • Park, Changhan;Song, Sungchan;Jung, Sangwoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.11
    • /
    • pp.898-905
    • /
    • 2018
  • In this work, infrared targets for a developed hardware-in-the-loop simulation(HILS) system are proposed for a performance test of a dual-sensor imaging seeker equipped with an infrared and a visible sensor that can lock and track for ground and air targets. This integrated system is composed of 100 modules of heat and light sources to simulate various kinds of target and the trajectory of moving targets based on scenarios. It is possible to simulate not only the position, velocity, and direction for these targets but also background clutter and jamming environments. The design and measurement results of an infrared target, such as the HILS system configuration, developed for testing and evaluation of a dual-sensor imaging seeker are described. In the future, it is planned to test the lock-on and tracking performance of an imaging seeker equipped with single or dual sensors dynamically in real time based on a simulation flight scenario in the developed HILS system.

RF Heating of Implants in MRI: Electromagnetic Analysis and Solutions

  • Cho, Youngdae;Yoo, Hyoungsuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.2
    • /
    • pp.67-75
    • /
    • 2020
  • When a patient takes an MRI scan, the patient has a risk of unexpected injuries due to the intensive electromagnetic (EM) field. Among the injuries, the tissue heating by the time-varying EM field is one of the main issues. Since an implanted artificial structure with a conductive material aggravates the heating effect, lots of studies have been conducted to investigate the effect around the implants. In this review article, a mechanism of RF heating around the implants and related studies are comprehensively investigated.

On the Limitation of Telegrapher′s Equations for Analysis of Nonuniform Transmission Lines

  • Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.68-71
    • /
    • 2004
  • The limitation of telegrapher's equations for analysis of nonuniform transmission lines is investigated here. It is shown theoretically that the input impedance of a nonuniform transmission line cannot be derived uniquely from the Riccati equation only except for the exponential transmission line of a particular frequency-dependent taper. As an example, the input impedance of an angled two-plate transmission line is calculated by solving the telegrapher's equations numerically. The numerical results suffer from larger deviation from its rigorous solution as the plate angle increases.

Review of the Hidden Rays of Diffraction

  • Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • A high-frequency analysis technique, called the hidden rays of diffraction (HRD), is reviewed in this paper. The physical optics and the rigorous diffraction coefficients of a perfectly conducting wedge illuminated by a plane wave are compared. The physical existence of hidden rays on the shadow boundary is explained in view of the geometric theory of diffraction (GTD). In particular, a systematic tracing of hidden rays and its visualization are precisely described by introducing the concept of the supplementary boundary. The physical meaning of the null-field condition in the complementary region is also explained.

RF Resonators Using Microstrip Transmission Line at 3 T MRI (3 T 자기공명영상시스템에서의 마이크로스트립을 이용한 다양한 RF 공진기)

  • Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.663-666
    • /
    • 2013
  • This paper demonstrates four different radio frequency (RF) resonators at 3 T magnetic resonance imaging (MRI) system. An approach based on microstrip transmission line to identical RF resonators except upper stripline structure is investigated. Electromagnetic simulation results are compared for RF resonators and discussed in detail at 3 T.