• Title/Summary/Keyword: Electromagnetic (EM)

Search Result 473, Processing Time 0.02 seconds

Design of Two-Stage X-Band Power Amplifier Using GaN-HEMT (GaN-HEMT를 이용한 X-대역 이단 전력증폭기 설계)

  • Lee, Wooseok;Lee, Hwiseob;Park, Seungkuk;Lim, Wonseob;Han, Jaekyoung;Park, Kwanggun;Yang, Youngoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.20-26
    • /
    • 2016
  • This paper presents an X-band two-stage power amplifier using GaN-HEMT. Two-stage structure was adopted to take its high gain and simple inter-stage matching network. Based on a 3D EM simulation, the bond-wire inductance and the parasitic capacitance were predicted. By reducing bond-wire inductance, Q of the matching network is decreased and the bandwidth is improved. The implemented two-stage PA shows a power gain of more than 16 dB, saturated output power of more than 42.5 dBm, and a efficiency of more than 35 % in frequency range of 8.1~8.5 GHz with an operating voltage of 40 V.

Case History for Safe Diagnosis of Embankment Dike using Composite Analysis of Various Geophysical surveys (물리탐사 결과 복합해석을 통한 방조제 제체 정밀안전진단 사례)

  • Song, Sung-Ho;Seong, Baek-Uk;Kim, Young-Gyu;Kang, Mi-Kyung;Lee, Gyu-Sang;Kim, Yang-Bin
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.107-112
    • /
    • 2007
  • To establish the reinforce region and technique through the embankment dike after identifying the region of seawater inflow, we carried out small-loop electromagnetic (EM) survey, electrical resistivity survey and refraction seismic method. We also analyzed the distribution of electrical conductivity in reservoir with depth every two month and monitored water level variations with tidal variation in four observation wells located at seaside and reservoir side in order to analyze the relationship with survey results. From both the cross-correlation between tidal and water level variation at four wells and the distribution of electrical conductivity in reservoir with depth, the major portion of seawater inflow are identified through the embankment dike. From electromagnetic and electrical resistivity survey results, it was found that the seawater inflow were happened through several small regions at seaside and became wider near reservoir side. The 2-D inversion sections of refraction seismic method showed that the pebble-bearing sand layer is spread over the whole region with two to four width. From the this study, small-loop EM, electrical resistivity and refraction seismic surveys accompany with the distribution of electrical conductivity in reservoir with depth and the monitoring results for water level variations are revealed to be effective to identify seawater inflow pathway through embankment dike and to establish the reinforce region and technique through the embankment dike.

  • PDF

Mode Identification of Resonant Frequencies for a Dielectric Loaded Circular Cylindrical Cavity (유전체가 삽입된 원통형 공진기에서 공진주파수의 모드 구분)

  • Kim, Jin-Kook;Kim, Dong-Kyu;Choi, Hong-Ju;Hur, Jung;Lee, Sang-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.3
    • /
    • pp.351-358
    • /
    • 1999
  • This paper describes the mode identification of resonant frequencies in dielectric loaded circular cylindrical cavity. To identify the mode of resonant frequencies, the calculated resonant frequencies were compared with the simulated ones in the air-filled circular cylindrical cavity by Microstripes EM simulator. With z-oriented magnetic field excitation, we could get only TE mode resonance, while all the modes including TM mode were observed with $\phi$-oriented magnetic field excitation. We could identify the modes with the two excitation methods. We applied the identification method to a dielectric loaded circular cylindrical cavity and compared these results with experimental ones. To certify the method, we traced resonance frequencies with varying the dielectric height. We observed that the resonance of $TE_{011}$ mode was changed dramatically while the variation of the $TE_{111}$ and $TE_{211}$ modes are relatively small.

  • PDF

Design of a GaN HEMT 4 W Miniaturized Power Amplifier Module for WiMAX Band (WiMAX 대역 GaN HEMT 4 W 소형 전력증폭기 모듈 설계)

  • Jeong, Hae-Chang;Oh, Hyun-Seok;Heo, Yun-Seong;Yeom, Kyung-Whan;Kim, Kyoung-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.162-172
    • /
    • 2011
  • In this paper, a design and fabrication of 4 W power amplifier for the WiMAX frequency band(2.3~2.7 GHz) are presented. The adopted active device is a commercially available GaN HEMT chip of Triquint Company, which is recently released. The optimum input and output impedances are extracted for power amplifier design using a specially self-designed tuning jig. Using the adopted impedances value, class-F power amplifier was designed based on EM simulation. For integration and matching in the small package module, spiral inductors and interdigital capacitors are used. The fabricated power amplifier with $4.4{\times}4.4\;mm^2$ shows the efficiency above 50 % and harmonic suppression above 40 dBc for second(2nd) and third(3rd) harmonic at the output power of 36 dBm.

Design of Ku-Band BiCMOS Low Noise Amplifier (Ku-대역 BiCMOS 저잡음 증폭기 설계)

  • Chang, Dong-Pil;Yom, In-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.199-207
    • /
    • 2011
  • A Ku-band low noise amplifier has been designed and fabricated by using 0.25 um SiGe BiCMOS process. The developed Ku-band LNA RFIC which has been designed with hetero-junction bipolar transistor(HBT) in the BiCMOS process have noise figure about 2.0 dB and linear gain over 19 dB in the frequency range from 9 GHz to 14 GHz. Optimization technique for p-tap value and electro-magnetic(EM) simulation technique had been used to overcome the inaccuracy in the PDK provided from the foundry service company and to supply the insufficient inductor library. The finally fabricated low noise amplifier of two fabrication runs has been implemented with the size of $0.65\;mm{\times}0.55\;mm$. The pure amplifier circuit layout with the reduced size of $0.4\;mm{\times}0.4\;mm$ without the input and output RF pads and DC bais pads has been incorporated as low noise amplication stages in the multi-function RFIC for the active phased array antenna of Ku-band satellite VSAT.

Application of Geophysical Prospecting to Site Assessment of Waste Landfill (매립지 오염평가를 위한 물리탐사의 적용사례)

  • Lee, Cheol-Hyo;Park, Sam-Gyu
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2001.09a
    • /
    • pp.104-121
    • /
    • 2001
  • Recently, the pollution of soil and groundwater becomes a serious social problem, and geophysical exploration methods have been introduced as a remedial investigation method of subsurface. Digital technologies such as personal computer have revolutionized our ability to acquire large volume of data in a short term, and to produce more reliable results for subsurface image. Also, color graphics easily visualizes the survey results in a more understandable manner, and it is widely used for not only characterizing the contaminated subsurface but also monitoring contaminant and remedial process. In this paper, electrical resistivity and electromagnetic (EM) surveys were carried out in order to understand characteristics of waste landfills, and the applicability of geophysical prospecting to site assessment of waste landfill was also tested. According to the result, electrical resistivity and electromagnetic (EM) surveys were effective in estimating distribution of the leachate plume.

  • PDF

A Scheme for Computing Primary Fields in Modeling of Marine Controlled-Source Electromagnetic Surveys (해양전자탐사 모델링을 위한 1차장 계산법)

  • Kim, Hee-Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.3
    • /
    • pp.185-190
    • /
    • 2011
  • In marine controlled-source electromagnetic (CSEM) modeling, it may be difficult to evaluate primary fields accurately using conventional linear filters because they decay very rapidly with distance. However, since there exists a closed-form solution to the Hankel transform in TM mode for a homogeneous half space, we can assess the accuracy of linear filters for evaluating the Hankel transform. As a result, only nine out of 36 source-receiver pairs show that EM fields decrease linearly in semi-log scale with an increase of source-receiver distance, while EM fields are either 0 or not reduced significantly due to an effect of the air layer. There also exist closed-form solutions for the nine pairs, and the others can be evaluated accurately with a relatively short filter. This paper proposes a method which uses closed-form solutions for TM-mode Hankel transforms and a filter with 61 coefficients for TE-mode ones.

A Study on the Improvement of Efficiency and Linearity of Power Amplifier using PBG Structure (PBG 구조를 이용한 전력 증폭기의 효율 및 선형성 개선에 관한 연구)

  • 김병희;박천석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1182-1190
    • /
    • 2001
  • In this paper, microstrip photonic bandgap (PBG) structure with special perforation patterns etched on the line itself is analyzed and optimized in shape, then used for harmonic tuning of power amplifier. This PBG has an advantage in being fabricated and grounded. The dimension of unit lattice is enlarged vertically, but its input and output line maintain 50 Ω using tapered line. This modification from original structure can lessen possible error in etching PCB. The analysis and design of PBG structure are acquired from using EM simulation. The measured insertion loss of the final structure is 0.3 ∼0.4 dB, and its bandwidth of stopband is 6∼7 GHz. Measured results of improved characteristics by using PBG structure at the output of the power amplifier are 0.72∼0.99 dB in output power, 1.14∼7.8 % in PAE, and 1 dBc in the third IMD.

  • PDF

MMIC Low Noise Amplifier Design for Millimeter-wave Application (밀리미터파 응용을 위한 MMIC 저잡음 증폭기 설계)

  • 장병준;염인복;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1191-1198
    • /
    • 2001
  • MMIC low noise amplifiers for millimeter-wave application using 0.15 $\mu$m pHEMT have been presented in this paper. The design emphasis is on active device model and EM simulation. The deficiency of conventional device models is identified. A distributed device model has been adapted to circumvent the scaling problems and, thus, to predict small signal and noise parameters accurately. Two single-ended low noise amplifier are designed using distributed active device model for Q-band(40 ∼ 44 GHz) and V-band(58 ∼65 GHz) application. The Q-band amplifier achieved a average noise figure of 2.2 dB with 18.3 dB average gain. The V-band amplifier achieved a average noise figure of 2.9 dB with 14.7 dB average gain. The design technique and model employed provides good agreement between measured and predicted results. Compared with the published data, this work also represents state-of-the-art performance in terms of gain and noise figure.

  • PDF

A geophysical survey result over a hydrocarbon contaminated site (물리탐사를 이용한 국내 유류오염지역 조사 사례)

  • Song Yoonho;Park Sam Gyu;Seol Soon Jn;Choi Seong-Jun;Chung Seung-Hwan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2001.09a
    • /
    • pp.122-140
    • /
    • 2001
  • We have applied the geophysical survey, mainly electric and electromagnetic (EM) methods, to a test site contaminated by hydrocarbon waste disposal and local spill. The multi-frequency, moving source & receiver EM survey along with ground penetrating radar (GPR) showed a fairly good performance in detection of buried metal pipes and objects. Magnetic survey measuring vertical and horizontal gradients were so sensitive to the small metallic objects spread over the surface that it's hard to discriminate the buried pipe. We chose electrical resistivity, EM and GPR survey to examine the soil contamination. Depth slices of resistivity distribution as the results of the inversion of resistivity and EM data coincided each other and closely matched the contaminated area determined by chemical analysis of the soil samples. GPR images did not show the reflection events related with contamination plume since there are no distinct spill in this site. We inferred the contamination using the penetration depth of the GPR energy, which could be used as auxiliary information to the resistivity and EM results. We summarized the applicability of each survey methods based on this results and proposed a desirable survey scheme for the determination of hydrocarbon contaminated site.

  • PDF