Amperometric Enzyme Electrode for the Determination of $NH_4^+$ ($NH_4^+$ 정량을 위한 Amperometric Enzyme Electrode)

  • Moo Lyong Seo;Jae Sang Kim;Shim Sung Lee;Zun Ung Bae;Heung Lark Lee;Tae Myung Park
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.11
    • /
    • pp.937-942
    • /
    • 1993
  • Enzyme electrodes for amperometric measurement of ammonia was prepared by immobilization of L-glutamate dehydrogenase on an Immobilon-AV Affinity membrane and attachment to a glassy carbon electrode. Reduced nicotinamide adenine dinucleotide (NADH) was used as the electroactive species. The electrochemical oxidation of NADH was monitored at +1.0 volt vs. Ag/AgCl. Response was linear from $4.0\;{\times}\;10^{-5}\;to\;4.0\;{\times}\;10^{-4}$ M. The detection limit was 2.0 ${\times}\;10^{-6}$ M. Response time, the optimum pH and life time of enzyme immobilized membrane were 2 min, pH 7.3∼7.6 (Dulbecco's buffer solution) and about 25 days respectively. When the enzyme electrode was applied to the $NH_4^+$ determination with amperometric method, other physiological materials had no interference.

  • PDF

A Study on the Manufacturing Process of Fe-Ti Type Electrode for Ni/MH Secondary Battery (Ni/MH 2차전지용 Fe-Ti계 전극 제조공정에 대한 연구)

  • Joung, Sang-sik;Kim, Ki-won;Ahn, Hyo-jun;Joung, Soon-dol
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.9 no.2
    • /
    • pp.65-75
    • /
    • 1998
  • Five different processes were selected and tested to find an useful method of manufacturing Fe-Ti type electrode. Initially, FeTi alloy was prepared by melting in plasma arc furnace and then powdered for shaping. Electroless Ni plating on these powder particles before shaping improved the discharge characteristics. The effects of heat-treatments on the electrode characteristics were also investigated. The discharge capacities of electrods were increased with the increasing heat-treatment temperatures. When heat treated at $1000^{\circ}C$ after shaping, the best results were acquired in the discharge capacity and cycle life. Both electroless Ni plating and heat-treatment were appeared to be crucial for the performance improvement of FeTi type electrode. Fe-Ti -Mn electrodes were prepared according to the process suggested in this study and tested to verify the promising effects of that.

  • PDF

Electrochemical Characteristics of MnO2 Electrodes as a function of Manufacturing Process (제조공정에 따른 MnO2산화물 전극의 전기화학적 특성)

  • 김현식;이해연;허정섭;이동윤
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.486-491
    • /
    • 2004
  • Dimensionally stable anode(DSA) can be used for the hydro-metallurgy of non-ferrous metals like as Zn, and the electrolysis of sea water. MnO$_2$ electrode satisfies the requirements of DSA, and has a good cycle life and a low overpotential for oxygen evolution. MnO$_2$ electrodes based on Ti matrix were prepared by using thermal decomposition method and also MnO$_2$ was coated on Ti and Pb matrix with DMF and PVDF compositions. The MnO$_2$ electrodes prepared by thermal decomposition method had very weak adhesive strength onto Ti matrix and MnO$_2$ layer was removed out so that electrochemical properties for MnO$_2$ were not investigated. The viscosity of solvent used as a binder of MnO$_2$ Powder increased with the increasing PVDF contents. The thickness of the MnO$_2$ layer on Pb matrix in DSA, which was prepared with 5 times dipping at the solution mixed with PVDF : DMF = 1 : 9, was 150${\mu}{\textrm}{m}$. When the ratio of PVDF to MnO$_2$ was lower than 1 : 6, the Pb electrode didn't show any reaction irrespective of the concentrations of DMF. However, When the ratio of PVDF to MnO$_2$ was higher than 1: 6, the Pb electrode showed constant current reactions and homogeneous cyclic voltammetry even though at a high cycle. The reason for the high current and homogeneous cyclic voltammetry is the good catalytic reactions of MnO$_2$ powder in electrode.

Electrode properties upon the substitution of Mo for Mn in Zr-basd AB2-type Hydrogen Storage Alloys (Zr1-xTixV0.4Ni1.2Mn0.4-yMoy계 합금전극의 Mo 함량에 따른 물성 및 전극특성)

  • Seo, Chan-Yeol;Park, Choong-Nyeon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.11 no.4
    • /
    • pp.189-202
    • /
    • 2000
  • $AB_2$ type Zr-based Laves phases alloys have been studied for potential application as a negative electrode in a Ni-MH battery. The $AB_2$-type electrodes have a much higher energy density than $AB_5$-type electrodes per weight, however they have some disadvantages such as poor activation behavior and cycle life etc. Nonetheless, the $AB_2$-type electrodes have been studied very extensively due to their high energy density. In this study, in order to develop the cycle life, the Mn of $AB_2$ alloy composition was substituted partially by Mo. The alloys were melted by arc furnace and remelted 4-5 times for homogeneity. The alloy powder was used below 200-325 mesh for experiments. The structures and phases of the alloys were analyzed by XRD, SEM and EDS, and measured the curve of a pressure-composition isotherms. The electrodes were prepared by cold pressing of the copper-coated(25 wt%) alloy powders, and tested by a half cell. The results are summarized as follows. The cycle life was improved with the increase of Mo amount in $Zr_{1-x}Ti_xV_{0.4}Ni_{1.2}Mn_{0.4}Mo_y$(x=0.3, 0.4) and the activation was faster, whereas the discharge capacity decreased.

  • PDF

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System (ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링)

  • Han, Hee-Jo;Kim, Hak-Jin;Jung, Dae-Hyun;Cho, Woo-Jae;Cho, Yeong-Yeol;Lee, Gong-In
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.141-152
    • /
    • 2020
  • The rapid on-site measurement of hydroponic nutrients allows for the more efficient use of crop fertilizers. This paper reports on the development of an embedded on-site system consisting of multiple ion-selective electrodes (ISEs) for the real-time measurement of the concentrations of macronutrients in hydroponic solutions. The system included a combination of PVC ISEs for the detection of NO3, K, and Ca ions, a cobalt-electrode for the detection of H2PO4, a double-junction reference electrode, a solution container, and a sampling system consisting of pumps and valves. An Arduino Due board was used to collect data and to control the volume of the sample. Prior to the measurement of each sample, a two-point normalization method was employed to adjust the sensitivity followed by an offset to minimize potential drift that might occur during continuous measurement. The predictive capabilities of the NO3 and K ISEs based on PVC membranes were satisfactory, producing results that were in close agreement with the results of standard analyzers (R2 = 0.99). Though the Ca ISE fabricated with Ca ionophore II underestimated the Ca concentration by an average of 55%, the strong linear relationship (R2 > 0.84) makes it possible for the embedded system to be used in hydroponic NO3, K, and Ca sensing. The cobalt-rod-based phosphate electrodes exhibited a relatively high error of 24.7±9.26% in the phosphate concentration range of 45 to 155 mg/L compared to standard methods due to inconsistent signal readings between replicates, illustrating the need for further research on the signal conditioning of cobalt electrodes to improve their predictive ability in hydroponic P sensing.

An Experimental Study for Electro-active Polymer Electrode and Actuator (전기활성 고분자 전극 및 구동기에 관한 실험적 연구)

  • Lee, Jun-Man;Ryu, Sang-Ryeoul;Lee, Dong-Joo;Lin, Zheng-Jie
    • Composites Research
    • /
    • v.26 no.5
    • /
    • pp.289-294
    • /
    • 2013
  • A thinner is used to improve the multi-walled carbon nano-tube (CNT) and carbon black (CB) dispersion in a polymer matrix and to make a soft electrode. The electrical and mechanical properties of the soft electrodes are investigated as functions of CNT, CB and thinner content. The optimal mixing condition for the electrode is thinner 80, CNT 3.5, CB 18 (phr) on the basis of matrix (KE-12). The specific resistance of that is 73 (${\Omega}{\cdot}cm$), and tensile strength, tensile modulus, and elongation of that is 0.45 MPa, 0.21 MPa, and 184%, respectively. Also, a simple structure of the actuator with an optimized electrode and elastomer is fabricated and its characteristic is evaluated. At the operating voltage 25 kV, the displacement of an elastomer KE-12 is 2.24 mm, and that of an elastomer KE-12 with thinner 50 (phr) is 4.05 mm. It shows a higher displacement compared to that of 3M 4910 which has similar modulus. The actuator made with elastomer and electrode of the same material (KE-12) may have advantages for fatigue life and application.

Improved Cycle Performance of High-Capacity SiOx Negative Electrodes with Carbon Nanotube Conducting Agents for Lithium-Ion Batteries (탄소나노튜브 도전재 적용을 통한 리튬이온 이차전지용 고용량 SiOx 음극의 사이클 성능개선)

  • Hyang Sun Jeon;Ji Heon Ryu
    • Journal of the Korean Electrochemical Society
    • /
    • v.26 no.3
    • /
    • pp.35-41
    • /
    • 2023
  • The carbon-coated silicon monoxide (c-SiOx), which is a negative electrode active material for lithium-ion batteries (LIBs), has a limited cycle performance due to severe volume changes during cycles, despite its high specific capacity. In particular, the significant volume change of the active material can deform the electrode structure and easily damage the electron transfer pathway. To improve performance and mitigate electrode damage caused by volume changes, we replaced parts of the carbon black conducting agent with carbon nanotubes (CNTs) having a linear shape. The content of the entire conductive material in the electrode was fixed at 10% by mass, and the relative content of CNTs ranged from 0% to 25% by mass to prepare electrodes and evaluate electrochemical performance. As the CNT content in the electrode increased, both cycle life and rate capability improved. Even a small amount of CNT can significantly improve the electrochemical performance of a c-SiOx negative electrode with large volume changes. Furthermore, dispersing CNTs effectively can lead to achieving the equivalent performance with a reduced quantity of CNTs.

Evaluation of High Order Statistical Parameter for Electrochemical Noise Analysis

  • Kim, Jong Jip
    • Corrosion Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.296-299
    • /
    • 2008
  • High order statistical parameters were evaluated using the electrochemical noise data collected during corrosion of type 430 stainless steel coupled to a inert, platinum electrode in 3.5% NaCl solution. High order statistical parameters are shown to predict uniform corrosion properly. However, Localization index, skewness of current, kurtosis and skewness of potential are capable of predicting pitting corrosion only when the transients are large with long life time. Of the high order statistical parameters evaluated, kurtosis of current is found to be the most sensitive parameter for detecting uniform and pitting corrosion.

Amorphous Diamond for Generating Cold Cathode Fluorescence Light

  • Sung, James-C.;Kan, Ming-Chi;Hu, Shao-Chung
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.913-914
    • /
    • 2006
  • Amorphous diamond has a very low work function (1 eV) at modest temperature ($150^{\circ}C$). It has been coat coated on electron emitting electrodes. Such electrodes are used for cold cathode fluorescence lamps (CCFL) that illuminate liquid crystal displays (LCD) for rnote books and television sets. Amorphous diamond can dramatically reduce the turn-on voltage to lit CCFL so the lamp life can be greatly extended. Moreover, the electrical current can be increased to enhance the brightness of the light.

  • PDF