• 제목/요약/키워드: Electrode Installation

검색결과 287건 처리시간 0.023초

966nm 근적외선 레이저를 이용한 고저항성 바나듐 이산화물 박막 기반 2단자 평면형 소자에서의 양방향 전류 트리거링 (Bidirectional Current Triggering in Two-Terminal Planar Device Based on Highly Resistive Vanadium Dioxide Thin Film Using 966nm Near Infrared Laser)

  • 김지훈;이용욱
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.28-34
    • /
    • 2015
  • By incorporating a 966nm near infrared laser, we demonstrated bidirectional current triggering of between 0 and 10mA in a two-terminal planar device based on a highly resistive vanadium dioxide ($VO_2$) thin film grown by a pulsed laser deposition method. A two-terminal planar device, which had an electrode separation of $100{\mu}m$ and a $50{\mu}m-wide$ $VO_2$ conducting layer, was fabricated through ion beam-assisted milling and photolithographic techniques. A bias voltage range for stable bidirectional current triggering was determined by investigating the current-voltage curves of the $VO_2-based$ device in a current-controlled mode. Bidirectional current triggering of up to 10mA was realized by directly illuminating the $VO_2$ film with a focused infrared laser beam, and the transient responses of triggered currents were analyzed when the laser was modulated at various pulse widths and repetition rates. A switching contrast between off- and on-state currents was evaluated as ~3571, and the rising and falling times were measured as ~40 and ~20ms, respectively.

부싱 형상에 따른 전계 분포에 관한 연구 (A Study on Electric Field Distribution with Bushing Geometry)

  • 조국희
    • 조명전기설비학회논문지
    • /
    • 제22권5호
    • /
    • pp.7-12
    • /
    • 2008
  • 부싱의 형상에 따라 전계 분포를 비교하여 가장 효율적인 형상을 설계하고자 하였다. 본 연구에서 형상 변화는 12 조건이며 전극 길이의 변화로 벡터 분포도는 0.7[%], 전계 분포도는 약 $21{\sim}26[%]$의 절연 성능을 향상시킬 수 있었다. 그리고 고압부 절연물 두께의 변화는 벡터 분포도는 2[%], 전계 분포도는 약 $23{\sim}43[%]$의 절연 성능을 향상시킬 수 있었다. 따라서 조건변화에 따라 절연성능이 향상되는 것을 알 수 있으므로 부분방전 개시전압 소멸전압을 향상시킬 수 있을 것으로 사료된다.

농약살포시스템 이동을 위한 기구물 설치를 위한 대지 분석방법 (Earth Analysis Method for Installation of Equipment for Moving Pesticide Spraying System)

  • 부창진
    • 전기전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.1152-1157
    • /
    • 2018
  • 논문에서는 밭농사에 적합하도록 설계된 와이어 기반 농약살포장비의 이동을 위한 구조물 설치 위치의 어려움을 해결하고자 한다. 이를 위해 간접적으로 대지구조를 파악할 수 있는 대지저항률 측정방법과 분석기술을 적용한다. 선정된 밭농사 지역에 일정 간격의 전극을 현장에 설치하고 내장형 제어보드에 다수의 스위치를 구동시켜 대지저항률 데이터를 자동 취득한다. 그리고 2차원 영상복원 알고리즘을 사용하여 대지분석을 수행하고 그 결과를 통해 실제 구조물 타설에 적합한 최적지점을 선정하고자 한다.

긴 전극을 사용하는 전기비저항 탐사 (Resistivity Survey Using Long Electrodes)

  • 조인기;이근수;김연정;김래영
    • 지구물리와물리탐사
    • /
    • 제19권1호
    • /
    • pp.45-50
    • /
    • 2016
  • 일반적으로 전기비저항 탐사에서는 편의상 점 전원을 사용한다. 만약 철제 케이싱과 같이 긴 전극을 사용한다면 전기비저항 탐사의 탐사 깊이가 증가할 것으로 기대된다. 그러나 긴 전극을 사용하여 회득된 전기비저항 탐사 자료는 통상적인 자료 해석 프로그램으로 처리할 수 없다. 이는 긴 전극에 의해 생성된 1차 전위가 점 전원에 의한 1차 전위와는 서로 다르기 때문이다. 이 연구에서는 긴 전극을 여러 개의 연속된 점 전원으로 대치하는 새로운 전기비저항 탐사 자료 처리 방법을 제안하였다. 이 방법에 의한 전위 분포를 해석적/수치적 해와 비교한 결과, 유한 차분법이나 유한 요소법에 의한 긴 전극을 사용하는 전기비저항 탐사 모델링이 가능함을 확인하였다.

직류전원과 0가 철을 이용한 지하수내 TCE정화효율의 최적화 연구 (Optimal Remediation of TCE-contaminated Groundwater using Direct Current and Fe$^0$)

  • 문지원;문희수;노열;김헌기;송윤구
    • 자원환경지질
    • /
    • 제35권3호
    • /
    • pp.229-239
    • /
    • 2002
  • 본 연구는 직류전원(DC)과 zero valent iron(ZVI)을 이용한 실험실 규모의 투수성 반응벽의 모사를 통하여 야외규모의 반응벽 설치시 반응벽과 전원의 설치 위치에 따른 trichloroethylene(TCE)의 처리시 효율성과 반응벽 사용가능 수명을 알아보고자 하였다. 실험결과 12개의 컬럼 type 중 ZVI와 DC를 동시에 사용하는 경우, ZVI만을 사용하는 경우의다. TCE의 환원적 탈염소화는 촉진되었다. 설치된 ZVI충진물질의 양을 고려할 경우, 하류에 ZVI를 설치하고, 전극배열은 상류에 양극을, 하류에 음극을 배열하는 것이 가장 적은 실비로 높은 처리 효율을 나타냄이 밝혀졌다.

4전극 전기비저항 탐사장비의 개발 및 검증 (Development and Verification of 4-Electrode Resistivity Probe)

  • 김준한;윤형구;정순혁;이종섭
    • 대한토목학회논문집
    • /
    • 제29권3C호
    • /
    • pp.127-136
    • /
    • 2009
  • 본 연구의 목적은 포화지반의 전기적 특성파악을 위한 4전극 전기비저항 프로브(4-Electrode Resistivity Probe: 4ERP)의 개발과 검증이다. 4ERP는 웨너 배열을 적용하여 전극에서 분극작용 없이 전기비저항을 산정할 수 있도록 쐐기형과 평면형으로 제작되었다. 쐐기형은 지반속에 관입하기 위한 용도이며 평면형은 실내실험시 사용되는 셀등에 설치하기 위한 것이다. 크기가 다른 6종류의 글라스비드와 3종류의 모래를 사용하여 압밀시험을 수행한 결과, 간극률이 감소함에 따라 전기비저항이 증가하였으며, Arichie 공식에 사용되는 m값이 입자의 크기보다 형상에 영향을 받는 것으로 나타났다. 액상화 수조에서 수행된 실험결과 체적간극률과 유사한 전기비저항 간극률이 산정되었다. 대형 토조에서 수행된 관입실험으로부터 간극률 주상도를 얻을수 있었다. 본 논문에서 제시된 4ERP는 포화 지반의 간극률을 효과적으로 산정할 수 있는 장비가 될 수 있을것으로 판단된다.

HVDC 해수귀로용 전극설치 및 운영 개선 방안 (The Improvement Plan of Installation and Maintenance of electrode element In KEPCO Hae-Nam HVDC)

  • 이세일;장재원;박희웅;김명원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.527-529
    • /
    • 2005
  • 한국전력공사는 전남 해남군 및 제주도 제주시에 직류송전방식의 HVDC 설비를 '98. 03. 준공 운영 중이다. HVDC(High Voltage Direct Current)는 영국 GEC-Alstom의 150MW$\times$2 Pole 변환설비 및 프랑스 Alcatel사의 101km 해저케이블 2회선으로 구성되어 제주도 전력수요의 40%를 담당, 안정적 전력 공급과 발전 연료비 절감에 기여하고 있다. 본 논문은 변환설비 운영 중 해저케이블 1회선 고장 발생에 대비한 해수 귀로용 전극 설비의 기능유지에 적절한 구조물개선과 보수비용 절감을 위한 방법 및 운영 개선 방안에 대하여 고찰하였다.

  • PDF

딥스틱게이지형 소형 엔진열화감지센서 개발 (Development of a Dipstick Gage Type Small Engine oil Deterioration Detection Sensor)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제29권2호
    • /
    • pp.77-84
    • /
    • 2013
  • A small engine-oil-deterioration detection sensor was developed and installed at the tip of a dipstick gage. The sensor part was manufactured using printed circuit board (PCB) manufacturing technology. A set of sensor covers was installed in order to protect the sensor and realize good signal stability. The small engine-oil-deterioration detection sensor system comprised a dual sensor having etched copper electrodes coated with gold and ceramic, a flexible PCB (FPCB) acting as electric wire, and a dummy PCB with only a lock connector. The sensor can easily be installed by insertion through the guide tube of a dipstick gage. Thus, a driver can easily handle it without further installation equipment. The sensor can determine the level of deterioration in the engine oil by estimating the corresponding dielectric constant of the engine oil.

10kW급 인산형 연료전지 제작 및 운전 특성 (Fabrication and Operational Characteristics of 10kW Class PAFC)

  • 송락현;김창수;신동열;최수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1543-1545
    • /
    • 1998
  • In order to develop PAFC stack technology using 2.000$cm^3$ electrode-matrix, 10kW stack consisted of 63 single cell was fabricated and operated. The operation installation, and control and data acquision system for the 10kW PAFC stack were designed and equipped. The stack showed the performance of 10kW (275A at 36.5V) and uniform distribution of temperature and voltage between the cells.

  • PDF

전기집진장치의 코로나 전류 발생 전극 제작에 따른 추타력 비교에 관한 연구 (The Study of Comparison on Rapping Force on Generation of Corona Discharge Electrode of Electrostatic Precipitator)

  • 이강욱;박정호;장성호;임우택;서정민
    • 한국환경과학회지
    • /
    • 제26권2호
    • /
    • pp.231-238
    • /
    • 2017
  • Rapid industrial development has led to a serious problem of pollution in the industrial sector. With the increasing social need for environmental protection, research on air pollution prevention equipment for reducing pollutants in industrial processes is actively being undertaken. The deterioration of existent, installed facilities, their increased emission rates, and the strengthening of the effluent quality standards make complying with permissible emission standards difficult. In fact, installing new electric precipitators or complementing existent facilities is inevitable. The expansion and complementation of the installed electrical precipitators have led to improvements in dust collection efficiency, shorter working times, and lower costs. Because of its easy installation and simple manufacturing process, the production method with the discharge electrode of an electric precipitator is widely used. The following conclusions were reached by classifying discharge electrodes into four types based on the production method and mutually comparing them by their dust collection efficiency. None of the four types used in this study were damaged by impact. However, we were able to confirm some strain from the compression sites of both type A and type B. Both type B and type C are expected to have greater dust collection efficiencies than the other models due to their large vibration transmissibility. Moreover, the high vibrational energy is expected to cause rapping damage during its operation. Particularly, in the case of type B, some of the strain was found at the end of the compression site. The coupling schemes of both type C and type D are out of vibration transmissibility. On the other hand, the ability to maintain straightness and solidity of the side is regarded as outstanding and stable. Type D has outstanding on-site workability, considering the presence of locking, structural stability, and work conditions. From these experiments, we determined that type C is the most ideal connection method of discharge electrode, considering its construction period of renovation. Type C is inferior to type D with regard to on-site workability. However, type C has outstanding dedusting transmission with regard to the straightness, solidity maintenance, and vibration of shearing stress.