• 제목/요약/키워드: Electrochemical Detection

검색결과 340건 처리시간 0.024초

Solid Electrochemical Method of Measuring Hydrogen Concentration with O2-/H+ Hetero-Ionic Junction

  • Chongook Park
    • 센서학회지
    • /
    • 제33권2호
    • /
    • pp.63-69
    • /
    • 2024
  • A novel method for measuring hydrogen concentration is introduced, along with its working principle and a novel detection algorithm. This configuration requires no additional reference compartment for potentiometric electrochemical measurements; therefore, it is the most suitable for measuring dissolved hydrogen in the liquid phase. The sensor's electromotive force saturates at a certain point, depending on the hydrogen concentration during the heating process of the sensor operation. This dynamic temperature scanning method provides higher sensitivity than the constant temperature measurement method.

붕소가 도핑된 다이아몬드 전극을 이용한 생체화학물질의 검출 (Detection of Bio-chemical by Boron-doped Diamond Electrode)

  • 김규식;;;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.569-572
    • /
    • 2001
  • Selective. highly stable determination of epinephrine(adrenalin) was achieved in cyclic voltammetric measurement carried out at electrochemically treated conductive boron-doped diamond electrode. Boron-doped diamond electrodes were prepared on single crystal Si wafers by microwave plasma chemical vapor deposition and $B_{2}O_{3}$ was dissolved in acetone/methanol(9:1) mixture solution so that the B/C weight ratio ca. $10^{4}ppm$. Epinephrine is a kind of catecholamines, which secreted from adrenal marrow cells. The serious problem to detection of epinephrine is the interference phenomena of electroactive constituent. including AA. In this study. electrochemical treatment of BDD was carried out to discriminate between epinephrine and AA responses. Experimental results showed that the peak potential of AA oxidation shift to the positive direction and the oxidation peak of epinephrine was unchanged. The effect of electrochemical treatment was maintained up to 40hrs.

  • PDF

Electrochemical Behavior of Norfloxacin and Its Determination at Poly(methyl red) Film Coated Glassy Carbon Electrode

  • Huang, Ke-Jing;Xu, Chun-Xuan;Xie, Wan-Zhen
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권5호
    • /
    • pp.988-992
    • /
    • 2008
  • A poly(methyl red) film-modified glassy carbon electrode (PMRE) was fabricated for determination of norfloxacin (NFX). The electrochemical behavior of NFX was investigated and a well-defined oxidation peak with high sensitivity was observed at the film electrode. PMRE greatly enhanced the oxidation peak current of NFX owing to the extraordinary properties of poly(methyl red) film. Based on this, a sensitive and simple voltammetric method was developed for measurement of NFX. A sensitive linear voltammetric response for NFX was obtained in the concentration range of $1\;{\times}\;10^{-6}\;-\;1\;{\times}\;10^{-4}$ mol/L and the detection limit was $1\;{\times}\;10^{-7}$ mol/L using linear sweep voltammetry (LSV). The proposed method possessed advantages such as low detection limit, fast response, low cost and simplicity. The practical application of this new analytical method was demonstrated with NFX pharmaceuticals.

붕소가 도핑된 다이아몬드 전극을 이용한 생계화학물질의 검출 (Detection of Bio-chemical by Boron-doped Diamond Electrode)

  • 김규식;;;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.569-572
    • /
    • 2001
  • Selective, highly stable determination of epinephrine(adrenalin) was achieved in cyclic voltammetric measurement carried out at electrochemically treated conductive boron-doped diamond electrode. Boron-doped diamond electrodes were prepared on single crystal Si wafers by microwave plasma chemical vapor deposition and B$_2$O$_3$ was dissolved in acetone/methanol(1:1) mixture solution so that the B/C weight ratio ca. 10$^3$ppm.. Epinephrine is a kind of catecholamines, which secreted from adrenal marrow cells. The serious problem to detection of epinephrine is the interference phenomena of electroactive constituent, including AA. In this study, electrochemical treatment of BDD was carried out to discriminate between epinephrine and AA responses. Experimental results showed that the peak potential of AA oxidation shift to the positive direction and the oxidation peak of epinephrine was unchanged. The effect of electrochemical treatment was maintained up to 40hrs.

  • PDF

Laser ablation을 이용한 폴리이미드 필름 전극제조 및 전기화학적 글루코오즈 바이오센서 응용 (Fabrication of Polyimide Film Electrode by Laser Ablation and Application for Electrochemical Glucose Biosensor)

  • 박덕수
    • 센서학회지
    • /
    • 제22권5호
    • /
    • pp.357-363
    • /
    • 2013
  • An ultraviolet pulsed laser ablation of polyimide film coated with platinum has been used to enhance the sensitivity for the application as an electrochemical biosensor. Densely packed cones are formed on polyimide surface after UV irradiation which results in increase of surface area. In order to apply the sensitivity improvement of laser ablated polyimide film electrodes, the glucose oxidase modified biosensor was fabricated by using an encapsulation in the gel matrix through sol-gel transition of tetraethoxysliane on the surface of laser ablated polyimide film. The optimum conditions for glucose determination have been characterized with respect to the applied potential and pH. The linear range and detection limit of glucose detection were from 2.0 mM to 18.0 mM and 0.18 mM, respectively. The sensitivity of glucose biosensors fabricated with laser ablated polyimide film is about three times higher than that of plain polyimide film due to increase in surface area by laser ablation.

고분자 막이 코팅된 Boron doped diamond 전극에 의한 호르몬의 전기화학적 검출 효과 (Electrochemical detection effect of hormone in body by using polymer coated boron doped diamond electrode)

  • 황진희;조은인;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.611-614
    • /
    • 2003
  • The electrochemical oxidation of ascorbic acid(AA), serotonin(SE) and epinephrine(EP) have been performed at poly N,N-dimethylaniline(PDMA) film coated diamond electrode. This cationic polymer film is electrochemically deposited on boron-doped diamond electrode surface. Unlike the bard electrode, the polymer film-coated diamond electrode can well separate the oxidation potential of AA by 200mV. Thus this electrode can be successfully used for the simultaneoud detection of both species. Increases in the concentration of AA do not affect the reponse of EP and SE.

  • PDF

Boron doped diamond RDE에 의한 혈액내의 serotonin의 전기화학적 선택적 검출 효과 (Selective electrochemical detection effect of serotonin in blood by using boron doped diamond rotating disk electrode)

  • 황진희;조은인;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.930-933
    • /
    • 2003
  • The electrochemical oxidation of ascorbic acid(AA), serotonin(StT) and epinephrine(EP) have been performed ae poly N,N-dimethylanliline(PDMA) film coated diamond electrode. This cationic polymer film is electrochemically deposited on boron-doped diamond electrode surface. Unlike the bard electrode, the polyaer film-coated diamond electrode can well separate the oxidation potential of AA by 330mV. Thus this electrode can be successfully used for the simultaneoud detection of both species. Increases in the concentration of AA donot affect the reponse of EP and ST.

  • PDF

Fabrication of enzymatic biosensor based on the poly(3-thiophenecarboxylic acid-co-thiophene) polymer as electron-transfer materials

  • Kim, Soo-Yeoun;Jo, Hyeon-Jin;Choi, Seong-Ho
    • 한국응용과학기술학회지
    • /
    • 제36권1호
    • /
    • pp.269-278
    • /
    • 2019
  • We fabricated glucose oxidase (GOx)-modified biosensor for detection of glucose by physical immobilization of GOx after electrochemical polymerization of the conductive mixture monomers of the 3-thiophenecarboxylic acid (TCA) and thiophene (Th) onto ITO electrode in this study. We confirmed the successfully fabrication of GOx-modified biosensor via FT-IR spectroscopy, SEM, contact angle, and cyclic voltammetry. The fabricated biosensor has the detection limit of $0.1{\mu}M$, the linearity of 0.001-27 mM, and sensitivity of $38.75mAM^{-1}cm^{-2}$, respectively. The fabricated biosensor exhibits high interference effects to dopamine, ascorbic acid, and L-cysteine, respectively. From these results, the fabricated GOx-modified biosensor with long linearity and high sensitivity could be used as glucose sensor in human blood sample.

Electrochemical and Raman Spectroscopy Analysis for D- and L-Tryptophan-b-Cyclodextrin Inclusion Complexes

  • Jeong, Yu-Ra;Lee, So-Ra;Son, Pyeong-Soo;Choi, Seong-Ho
    • 한국응용과학기술학회지
    • /
    • 제32권3호
    • /
    • pp.451-460
    • /
    • 2015
  • An enantioselective recognition of D- and L-tryptophan (Trp)-b-cyclodextrin (CD) inclusion complex was performed using electrochemical and FT-Raman spectroscopic analysis. From the electrochemical analysis, the selectivity coefficient ($K_{DL}$) of b-CD inclusion complexes was found higher than that of the D- and L-Trp in phosphate buffered saline (PBS, pH=7.0) solution. The percentage of enantioselectivity ($I_{%{ee}}$) for peak current of D-Trp-b-CD inclusion complexes was observed higher than that of L-Trp-b-CD inclusion complexes in PBS solution. From Raman spectroscopy, chemical shift difference (D, $cm^{-1}$) for the C=C stretch, ring vibration, and ring breathing of D-Try-b-CD inclusion complex were observed higher than that of L-Trp-b-CD inclusion complex. The electrochemical and Raman spectroscopic analyses were found very useful for chiral detection of racemic amino acid in the presence of b-CD.