• 제목/요약/키워드: Electrochemical Detection

검색결과 340건 처리시간 0.028초

전기화학적 방법에 의한 바이오칩의 SNP 검출 (SNP Detection of Biochip Using Electrochemical System)

  • 최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2128-2130
    • /
    • 2004
  • High throughput analysis using a DNA chip microarray is powerful tool in the post genome era. Less labor-intensive and lower cost-performance is required. Thus, this paper aims to develop the multi-channel type label-free DNA chip and detect SNP (Single nucleotide polymorphisms). At first, we fabricated a high integrated type DNA chip array by lithography technology. Various probe DNAs were immobilized on the microelectrode array. We succeeded to discriminate of DNA hybridization between target DNA and mismatched DNA on microarray after immobilization of a various probe DNA and hybridization of label-free target DNA on the electrodes simultaneously. This method is based on redox of an electrochemical ligand.

  • PDF

Electrochemical Determination of 6-Benzylaminopurine (6-BAP) Using a Single-wall Carbon Nanotube-dicetyl Phosphate Film Coated Glassy Carbon Electrode

  • Li, Chunya
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권7호
    • /
    • pp.991-994
    • /
    • 2006
  • Herein, insoluble single-walled carbon nanotube (SWNT) was successfully dispersed into water in the presence of a special kind of surfactant-dicetyl phosphate (DCP), subsequently, a SWNT-DCP composite film coated glassy carbon electrode (GCE) was fabricated. The electrochemical behaviors of 6-benzylaminopurine (6-BAP) at the unmodified GCE and SWNT-DCP modified GCE were examined. It is found that the SWNT-DCP modified GCE remarkably enhances the oxidation peak current of 6-BAP, indicating great potential in the determination of trace level of 6-BAP. Finally, a sensitive and simple voltammetric method with a good linear relationship in the range of ${\times}5.0\;\;10^{-8}\sim 2.5\;{\times}\;10^{-6}$ mol/L, was developed for the determination of 6-BAP. The detection limit is as low as $2.0\;{\times}\;10^{-8}$ mol/L for 3-min accumulation. This newly-proposed method was successfully demonstrated with practical samples.

Electrochemical Investigation of Bovine Hemoglobin at an Acetylene Black Paste Electrode in the Presence of Sodium Dodecyl Sulfate

  • Zhan, Guoqing;Li, Chunya;Luo, Dengbai
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권10호
    • /
    • pp.1720-1724
    • /
    • 2007
  • Electrochemical behaviors of bovine hemoglobin (Hb) at an acetylene black paste electrode based on the enhancement effect of sodium dodecyl sulfate (SDS) were investigated. In the optimal conditions, a very weak reduction peak was observed at an acetylene black paste electrode for hemoglobin in the absence of SDS. However, the reduction peak current increased remarkably after the addition of 4.0 × 10?4 mol L?1 SDS, suggesting that SDS exhibits obvious enhancement effect to the determination of hemoglobin. All the experimental parameters, such as pH value, concentration of SDS, accumulation time and accumulation potential were optimized for hemoglobin analysis. The proposed method possesses high sensitivity (detection limit is 3.0 × 10?9 mol L?1), wide linearity (6.0 × 10?9 to 6.0 × 10?7 mol L?1), rapid response and low cost. Finally, the method was successfully employed to determine hemoglobin in a spiked sample.

전기화학적 부식촉진 기법을 이용한 철근 콘크리트 부식의 영향평가 (Application of Electrochemical Accelerated Corrosion Technique to Detection of Reinforcing Corrosion in Concrete)

  • 이수열;이재봉;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.675-678
    • /
    • 1999
  • Rebar corrosion in concrete containing both chloride ions and calcium nitrite inhibitors were investigated by the various electrochemical methods. Rebar corrosion was accelerated by applying the impressed current to the rebar in concrete. Effect of chloride content and inhibitors on rebar corrosion were evaluated. Accelerated corrosion technique is the method to measure the time to the initiation of cracks of reinforced concretes, by applying constant voltage between rebar and the stainless steel cathedes. The increase of concentration of chloride ions in concrete result in the increase in anodic currents and the reduction of time to crack. However addition of inhibitors did not improve corrosion resistance of rebar in concrete. Rebar corrosion in concrete with chloride ions and inhibitors was also analyzed by the immersed tests though the mesurement of corrosion potentials.

  • PDF

Voltammetric Assay of Antibiotics for Modified Carbon Nanotube Sensor

  • Ly, Suw-Young;Yoo, Hai-Soo;Lee, Chang-Hyun
    • 한국응용과학기술학회지
    • /
    • 제29권3호
    • /
    • pp.443-449
    • /
    • 2012
  • A investigation of electrochemical analysis of antibiotics Neomycin ($C_{23}H_{46}N_6O_{13}$) was searched using electrochemical square wave (SW) stripping and cyclic voltammetry (CV) using working sensor of the modified carbon nanotube combination electrodes, optimum diagnostic parameters were searched by anodic stripping, final conditions were attained to working range of 1.0-14.0 ng/L, detection limit (S/N) was found to be 0.6 ng/L. The developed method was discovered to be fitting in quality control in the food, pharmaceutical and other manufacturing sectors.

Electrochemical Immunosensor Using the Modification of an Amine-functionalized Indium Tin Oxide Electrode with Carboxylated Single-walled Carbon Nanotubes

  • Aziz, Md.Abdul;Yang, Hae-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권7호
    • /
    • pp.1171-1174
    • /
    • 2007
  • We have developed an electrochemical immunosensor that combines the electrocatalytic property of carbon nanotube and the low background current of indium tin oxide (ITO) electrode. A partial monolayer of carboxylated single-walled carbon nanotube (CCNT) is covalently formed on an ITO electrode modified with amine-terminated phosphonic acid. Nonspecifically adsorbed avidin on the hydrophobic sidewalls of CCNT is used to immobilize biotinylated antibody and to reduce the nonspecific binding to CCNT. The biotinylated antimouse IgG bound on avidin and the antimouse IgG conjugated with alkaline phosphatase (ALP) sandwiches a target mouse IgG. ALP catalyzes the conversion of p-aminophenyl phosphate monohydrate into p-aminophenol, which is electrocatalytically oxidized to p-quinone imine on CCNT surface. Moderate electrocatalytic electrode obtained with the combination of CCNT and ITO allows low detection limit (0.1 ng/ mL).

Pyrocatechol Violet Modified Graphite Pencil Electrode for Flow Injection Amperometric Determination of Sulfide

  • Emir, Gamze;Karakaya, Serkan;Dilgin, Yusuf
    • Journal of Electrochemical Science and Technology
    • /
    • 제11권3호
    • /
    • pp.248-256
    • /
    • 2020
  • In this study, pyrocatechol violet (Pcv) is proposed for the first time as an efficient electrocatalyst for oxidation of sulfide and flow injection analysis (FIA) of sulfide. A graphite pencil electrode (GPE) was modified with Pcv via immersion of the GPE into 0.01 M Pcv solution for 15 min. Cyclic voltammograms (CVs) demonstrated that Pcv/GPE exhibits a good electrocatalytic performance due to shift in the potential from +400 at bare GPE to +70 mV at Pcv/GPE and obtaining an enhancement in the peak current compared with the bare GPE. A linear range between 0.25 and 250 μM sulfide with a detection limit of 0.07 μM was obtained from the recorded current-time curves in Flow Injection Analysis (FIA) of sulfide. Sulfide in water samples was also successfully determined using the proposed FI amperometric methods.

Preparation and Characterization of a Surface Renewable Solid State Hg/HgO Reference Electrode Utilizing Gold Amalgam

  • Kim, Won;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권3호
    • /
    • pp.439-442
    • /
    • 2007
  • A solid state Hg(Au)/HgO reference electrode was prepared utilizing gold amalgam solid particles. Solid fine powder of the gold amalgam was prepared by chemical reduction of Au(III) with NaBH4 followed by reduction of Hg(II) in the presence of gold fine particles. The solid content in the suspension of the gold amalgam particles and fine mercury oxide particles in DMF containing PVC was precipitated by the addition of a large amount of water to give solid Hg(Au)/HgO/PVC mixture. After drying, the mixture was pressure-molded to a physically stable Hg(Au)/HgO composite reference electrode material. The electrochemical characteristics of the electrode as a reference electrode were very similar to an ordinary Hg/HgO reference electrode. The electrode material can be molded and fabricated in any desired shape and size. The surface can be renewed by a simple polishing process whenever contaminated or deactivated. The applicability of the electrode in the electrochemical detection of carbohydrates after anion exchange separation was evaluated.

Prussian blue가 전착된 indium tin oxide 전극을 이용한 전기화학적 검출기 (An Electrochemical Detector Using Prussian Blue Electrodeposited Indium Tin Oxide Electrode)

  • 이인제;김주호;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.449-452
    • /
    • 2005
  • We fabricated an electrochemical detector (ECD) to catalyze redox reaction efficiently by electrodepositing Prussian blue (PB) on the indium tin oxide (ITO) electrode. Capillary electrophoresis (CE) and amperometric method were used. We investigated the PB surface properties by topography from atomic force microscopy (AFM). Also PB film thickness calibration with respect to deposition time and voltage was used to get better PB surFace. The PB thin film of dense and smooth surface could catalyze redox reaction efficiently. Comparing with CE-ECD microchip using bare-lTO electrode, proposed CE-ECD microchip using PB deposited electrode has shown better sensitivity by determining the detected peak current from the electropherograms while the concentration of tested analyzes was maintained the same. It is verified that detection limit can be lowered for 0.01 mM of dopamine and catechol respectively.

Electrochemical Determination of Ciprofloxacin Based on the Enhancement Effect of Sodium Dodecyl Benzene Sulfonate

  • Zhang, Shenghui;Wei, Shuang
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권4호
    • /
    • pp.543-546
    • /
    • 2007
  • Herein, a new electrochemical method was described for the determination of ciprofloxacin based on the enhancement effect of an anionic surfactant: sodium dodecyl benzene sulfonate (SDBS). In pH 4.0 phosphate buffer and in the presence of 1.0 × 10-4 mol/L SDBS, ciprofloxacin yields a well-defined and sensitive oxidation peak at the carbon paste electrode (CPE). Compared with that in the absence of SDBS, the oxidation peak current of ciprofloxacin remarkably increases in the presence of SDBS. The experimental parameters, such as supporting electrolyte, concentration of SDBS, and accumulation time, were optimized for ciprofloxacin determination. The oxidation peak current is proportional to the concentration of ciprofloxacin over the range from 8.0 × 10-8 to 5.0 × 10-6 mol L-1. The detection limit is 2.0 × 10-8 mol L-1 after 2 min of accumulation. This new voltammetric method was successfully used to detect ciprofloxacin in drugs.