• Title/Summary/Keyword: Electricity IT

Search Result 1,879, Processing Time 0.023 seconds

The Co-Combustion Characteristics of Coal and Wood Pellet in a 25W Lab-scale Circulating Fluidized Bed Reactor (25W급 순환유동층반응기에서 석탄과 우드펠릿의 혼소 특성 연구)

  • Kim, Jin Ho;Yang, Sang Yeol;Kim, Gyu Bo;Jeon, Chung Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.8
    • /
    • pp.683-691
    • /
    • 2015
  • Circulating Fluidized Bed(CFB) combustion has the several advantages which are the fuel flexibility, the economy, the efficiency and the environment. It is necessary to apply a renewable energy to produce electricity due to the Renewable Portfolio Standard(RPS) mandates recently. So, in this study, co-combustion with a coal and a wood pellet was investigated to evaluate the combustibility and the environment as function of blending ratio of them in a Lab-scale CFB reactor. To investigate the characteristics of the co-combustion, the blending ratio which is the weight of wood pellet by the total calorific value of the supplied, was considered. Bed material was a river sand(No. 7). As increasing the blending ratio, the exhausted gas emissions such as CO, NOx, HC and SOx were decreased. But in case of wood pellet over 30%, CO, HC and SOx emission were increased. And the gas temperatures at the downstream were decreased.

Effects of productivity of Lentinula edodes according to the control of high-temperature environment in summer (여름철 표고 톱밥재배의 고온환경조절이 버섯생산성 향상에 미치는 영향)

  • Kim, In-Yeop;Kim, Seon-Cheol;Noh, Jong-Hyun;Choi, Sun-Gyu;Lee, Won-Ho;Ko, Han-Gyu;Park, Heung-Soo;Koo, Chang-Duk
    • Journal of Mushroom
    • /
    • v.13 no.4
    • /
    • pp.288-293
    • /
    • 2015
  • In the structural investigation of cultivation facilities, the proportion of farmers to grown with double or triple structure were investigated 96%. It has been shown to grow with a stable cultivation facilities structure against environmental changes. The results of the analysis of the changes in the cultivation environment of Yeoju area in July-august, temperature and humidity of the external instrument shelter was $20.2{\sim}29.9^{\circ}C$ and 66.2~99.9% respectively. In the greenhouse 2 model capable of temperature environment regulation in the cultivation facility, temperature and humidity were investigated $19.3{\sim}25.7^{\circ}C$ and 81.6~99.9% respectively. Result of the survey of fruiting body characteristics and yields in the greenhous 2, pileus diameter and stipe length were investigated 66.2 and 54.1 mm, yield of mushroom and individual weight were 312 g and 26.6 g. High-temperature environment regulation shows the improvement of the quality and productivity of the mushroom. Power consumption of the air conditioning has been investigated using 56kwh/day, electricity costs were calculated 2195 won/day.

A LSTM Based Method for Photovoltaic Power Prediction in Peak Times Without Future Meteorological Information (미래 기상정보를 사용하지 않는 LSTM 기반의 피크시간 태양광 발전량 예측 기법)

  • Lee, Donghun;Kim, Kwanho
    • The Journal of Society for e-Business Studies
    • /
    • v.24 no.4
    • /
    • pp.119-133
    • /
    • 2019
  • Recently, the importance prediction of photovoltaic power (PV) is considered as an essential function for scheduling adjustments, deciding on storage size, and overall planning for stable operation of PV facility systems. In particular, since most of PV power is generated in peak time, PV power prediction in a peak time is required for the PV system operators that enable to maximize revenue and sustainable electricity quantity. Moreover, Prediction of the PV power output in peak time without meteorological information such as solar radiation, cloudiness, the temperature is considered a challenging problem because it has limitations that the PV power was predicted by using predicted uncertain meteorological information in a wide range of areas in previous studies. Therefore, this paper proposes the LSTM (Long-Short Term Memory) based the PV power prediction model only using the meteorological, seasonal, and the before the obtained PV power before peak time. In this paper, the experiment results based on the proposed model using the real-world data shows the superior performance, which showed a positive impact on improving the PV power in a peak time forecast performance targeted in this study.

Fuel cell based CHP technologies for residential sector (연료전지와 마이크로 열병합 발전기술)

  • Son, Young Mok
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.251-258
    • /
    • 2016
  • This article reports current status of micro fuel cell-combined heat and power (${\mu}FC$-CHP) systems which utilize both power and heat generated by fuel cells. There are several options for constructing CHP systems and among them, fuel cells are the most useful and their total energy efficiency combining heat and power can reach up to about 90%. Fuel cells are classified as five types based on the electrolyte, but the most suitable fuel cell types for the ${\mu}FC$-CHP system are proton exchange membrane fuel cells (PEMFCs) and solid oxide fuel cells (SOFCs). ${\mu}FC$-CHP systems have several advantages such as decrease of the transmission-distribution loss, reduced costs of electricity due to distributed power generation, and environmental-friendliness owing to zero emission. The main drawback of the ${\mu}FC$-CHP systems is the high initial investment, however, it keeps decreasing as the technology development reduces production costs. Currently, Japan is the most leading country of the ${\mu}FC$-CHP market, however, Korea tries to expand the market by planning the deployment of 1 million units of ${\mu}FC$-CHP systems and governmental subsidiary supporting of half of the install price. In this report, integration technologies for connecting FC and CHP, and technology trends of leading countries are presented as well.

Analysis of cause of engine failure during power generation using biogas in sewage treatment plant (하수처리장 바이오가스를 이용한 발전시 가스엔진의 고장원인 분석)

  • Kim, Gill Jung;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.13-29
    • /
    • 2016
  • In this study, we analyzed the causes of major faults in the biogas plant through the case of gas engine failure when cogenerating electricity and heat using biogas as a fuel in the actual sewage treatment plant and suggested countermeasures. Hydrogen sulfide in the biogas entering the biogas engine and water caused by intermittent malfunction of the water removal system caused intercooler corrosion in the biogas engine. In addition, the siloxane in the biogas forms a silicate compound with silicon dioxide, which causes scratches and wear of the piston surface and the inner wall of the cylinder liner. The substances attached to the combustion chamber and the exhaust system were analyzed to be combined with hydrogen sulfide and other impurities. It is believed that hydrogen sulfide was supplied to the desulfurization plant for a long period of time because of the high content of hydrogen sulfide (more than 50ppm) in the biogas and the hydrogen sulfide was introduced into the engine due to the decrease of the removal efficiency due to the breakthrough point of the activated carbon in the desulfurization plant. In addition, the hydrogen sulfide degrades the function of the activated carbon for siloxane removal of the adsorption column, which is considered to be caused by the introduction of unremoved siloxane waste into the engine, resulting in various types of engine failure. Therefore, hydrogen sulfide, siloxane, and water can be regarded as the main causes of the failure of the biogas engine. Among them, hydrogen sulfide reacts with other materials causing failure and can be regarded as a substance having a great influence on the pretreatment process. As a result, optimization of $H_2S$ removal method seems to be an essential measure for stable operation of the biogas engine.

Acceleration of Wound Healing and Collagen Deposition in Rat Skin by High Voltage Pulsed Current Stimulation (고전압맥동전류자극이 흰쥐 피부 창상치유와 교원질 축적에 미치는 효과)

  • Lee Jae-hyoung;Song In-young;Kim Jong-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.1-12
    • /
    • 2003
  • The purpose of this study was to investigate the effect of high voltage pulsed current stimulation (HVPCS) on the healing rate of a dermal wound in a rat. We also determined the mechanism of promoting healing by HVPCS. Twenty male Sprague-Dawley rats were randomly divided into two group; HVPCS group (n=10) and control group (n=10). The HVPCS rats received electrical stimulation with a current intensity of 50 V at 100 pps for a duration of 30 minutes, while the control group was given the same treatment without electricity for a week. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with Masson's trichrome, hematoxylin and eosin (H&E). The fibroblasts and collagen density were counted using a light microscope and computerized image analysis system and calculated as the density and the percent. A Student t-test showed a significantly higher wound healing rate of the HVPCS group than control (t=-4.161, p<0.001). The fibroblasts in the HVPCS group were higher than in the control group (t=-4.921, p<0.001). The density of collagen in the HVPCS group was also higher than in the control group (t=-4.367, p<0.001). These results indicate that the HVPCS accelerated the rate of healing in dermal wound, and increased fibroblasts and collagen density in the regenerative dermis. These findings suggest that the HVPCS may activate fibroblasts by alteration of the electrical environment, and it may increase collagen synthesis in the regenerative dermal wound.

  • PDF

A Study of the Heating Systems used by Korean Compatriot in Russia - Focusing on Yunhaeju, Kazakhstan and Uzbekistan- (러시아에 거주하는 고려인의 난방 방식에 관한 연구 -연해주, 카자흐스탄, 우즈베키스탄을 중심으로-)

  • Lee YoungShim;Cho JaeSoon;Lee SangHae;Joung JaeKook
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.1 s.203
    • /
    • pp.145-165
    • /
    • 2005
  • In 1937, most Korean compatriot who lived in Yunhaeju moved to Kazakhstan and Uzbekistan in Central Asia following the deportation policy of Russia. Korean compatriot have kept their traditional life style for 140 years, without a deep relationship with Korea. This study examined the heating systems of Korean compatriot in Yunhaeju, Kazakhstan and Uzbekistan, Russia. A literature review and field research, based on Ethnography as a research method, was employed. The results of the research were as following: 1) Korean compatriot in Yunhaeju use a Pechika, which is a radiator that uses hot water, and a Gudul as the main heating systems, but the use of a Pechika was most common. A Pechika functions for cooking as well as for warming the house. The room with the Gudul was connected to the kitchen, so this space was used as a place for cooking and eating, for family members to meet. Many kinds of fuel, like gas and electricity, were used to power the heating systems. 2) Korean compatriot in Kazakhstan use radiators, with hot water as the main heating system, with ratio using Gudul used in this region being the highest of all the three areas. The most common fuels used for a Gudul were wood and coal, and gas was also used in cooking. The room with the Gudul was planned to be located beside the fireplace, without any walls. The people using a Gudul use that place for eating and meeting, as well as for family members to sleep. 3) The main heating system of Korean compatriot in Uzbekistan was a radiator using hot water, and those with pipes containing hot water buried under the floor were very common. The function is very similar to that of a Gudul, so most people using this type of radiator would sleep on the floor. Those people with a traditional Gudul not using them were mostly in Uzbekistan. The reason for this was that the family members had diminished, so it was hard work for elderly parents to manage an extra building containing a Gudul. Gas was the fuel generally used for heating and cooking in Uzbekistan. 4) Guduls were used in the Korean compatriot's houses in all three areas, even though they have changed in structure to adapt to the Russian life style. However, Guduls have still been functioning to maintain a traditional life style in Korean compatriot's houses for the gathering of family members.

Performance analysis of 20 kW OTEC power cycle using various working fluids (다양한 작동유체를 이용한 20 kW급 해양온도차 발전 사이클 성능 분석)

  • Yoon, Jung In;Ye, Byung Hyo;Heo, Jung Ho;Kim, Hyun Ju;Lee, Ho Saeng;Son, Chang Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.836-842
    • /
    • 2013
  • In this paper, the 20 kW Ocean Thermal Energy Conversion(OTEC) is newly proposed in order to select the refrigerant that makes the cycle performance be optimized and the performance of 20 kW OTEC applying 15 pure refrigerants and 16 mixed refrigerants is analyzed. The efficiency of system, the mass flow of working fluids and TPP, which is new concepts, are analyzed. In view of cycle efficiency, R32/R152a (87:13) is the highest efficiency among the refrigerants. At the mass flow of working fluid to make the 20 kW electricity, R717 is shown as the lowest value. And in view of TPP in this study, R32/R134a 70:30 is the most optimized refrigerant. The analysis can confirm that the refrigerant is different along with the part of the system, so it is necessary to select the optimized refrigerant for 20 kW OTEC.

A Study on the Design of Power System for Buoy (등부표 전력 시스템 설계에 관한 연구)

  • Jo, Kwan-Jun;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.35 no.8
    • /
    • pp.631-636
    • /
    • 2011
  • Stable power supply to a light mounted on a navigational buoy is indispensable factor because unstable power can lead to fatal marine accident. Despite the difference lies between onshore and offshore environment, as well as the power output characteristics, the PV(Photovoltaic) power generation system is designed by the independent onshore power generation system standards. Furthermore, the capacity of PV power generation system does not take into account the structural characteristics of the buoy in the sea. Therefore, the faulty design makes battery over-discharge owing to lack of the power generation and the battery can not supply stable power to the light. This paper introduces a design method for a power system of the PV powered buoy. The data has been acquired for 3 months period, which includes PV-generated electricity, power consumption and battery voltage from experimental buoy. Further, a power management features of the buoy has been analyzed based on the acquired data. From the analysis of the acquired data, it was evident that PV power generation system produces different electric power output depend on its installed environment - land and sea. Based on the analytical result, a design criterion has been proposed for the power system in the navigational buoy.

Analysis of Microbial Communities in Aquatic Sediment Microbial Fuel Cells Injected with Glucose (포도당을 주입한 수중퇴적물을 이용한 연료전지시스템에 있어서 미생물군집 분석)

  • Kim, Min;Ekpeghere, Kalu I.;Kim, Soo-Hyeon;Chang, Jae-Soo;Koh, Sung-Cheol
    • Korean Journal of Microbiology
    • /
    • v.48 no.4
    • /
    • pp.254-261
    • /
    • 2012
  • The purpose of this research was to optimize electric current production of sediment microbial fuel cells by injecting glucose and to investigate its impact on microbial communities involved. It was shown that injection of proper concentration of glucose could increase electric current generated from sediment microbial fuel cells. When 1,000 mg/L of glucose, as opposed to higher concentrations, was injected, electric current increased up to 3 times. This increase is mainly attributed to the mutual relationship between fermenting bacteria and exoelectrogenic bacteria. Here the organic acids generated by fermenting bacteria could be utilized by exoelectrogenic bacteria, removing feedback inhibition caused by the organic acids. When glucose was injected, the population of Clostridium increased as to ferment injected glucose. Glucose fermentation can have either a positive or negative effect on electric current generation. When exoelectrogenic bacteria may readily utilize the end-product, electric current could increase. However, when the end-product was not readily removed, then detrimental chemical reactions (pH decrease, methane generation, organic acids accumulation) occurred: exoelctrogenic bacteria population declined and non-microbial fuel cell related microorganisms prospered. By injecting a proper concentration of glucose, a mutual relationship between fermenting bacteria, such as Clostridium, and exoelectrogenic bacteria, such as Geobacter, should be fulfilled in order to increase electricity production in mixed cultures of microorganisms collected from the aquatic sediments.