• 제목/요약/키워드: Electrical wiring

검색결과 204건 처리시간 0.026초

A critical comparison of reflectometry methods for location of wiring faults

  • Furse, Cynthia;Chung, You Chung;Lo, Chet;Pendayala, Praveen
    • Smart Structures and Systems
    • /
    • 제2권1호
    • /
    • pp.25-46
    • /
    • 2006
  • Aging wiring in buildings, aircraft and transportation systems, consumer products, industrial machinery, etc. is among the most significant potential causes of catastrophic failure and maintenance cost in these structures. Smart wire health monitoring can therefore have a substantial impact on the overall health monitoring of the system. Reflectometry is commonly used for locating faults on wire and cables. This paper compares Time domain reflectometry (TDR), frequency domain reflectometry (FDR), mixed signal reflectometry (MSR), sequence time domain reflectometry (STDR), spread spectrum time domain reflectometry (SSTDR) and capacitance sensors in terms of their accuracy, convenience, cost, size, and ease of use. Advantages and limitations of each method are outlined and evaluated for several types of aircraft cables. The results in this paper can be extrapolated to other types of wire and cable systems.

Real-Time Power Electronics Remote Wiring and Measurement Laboratory (PermLAB) Using 3-D Matrix Switching Algorithms

  • Asumadu, Johnson A.;Tanner, Ralph;Ogunley, Hakeem
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.611-620
    • /
    • 2010
  • This paper presents a new architecture, called "Power Electronics Remote Wiring and Measurement Laboratory (PermLAB)", that translates a common gateway interface (CGI) string from a remote web user to a web server connected to a 3-dimension switching matrix board, can be used to switch on and off, and to control a cluster of instruments and components. PermLAB addresses real-time connection, switching, and data acquisition over the Internet instead of using simulated data. A software procedure uses a signature system to identify each instrument and component in a complex system. The Web-server application is developed in HTML, JavaScript and Java, and in C language for the CGI interface, which resides in a controller portion of LabVIEW. The LabVIEW software fully integrates the Web sever, LabVIEW data acquisition boards and controllers, and the 3-dimensional switching matrix board. The paper will analyze a half-wave rectifier (AC - DC converter) circuit connected over the Internet using the PermLAB. PermLAB allows students to obtain real data by real-time wiring of real circuits in the laboratory using a "virtual breadboard" on the Web. The software for the Web-based 3-dimensional system is flexible, portable, can be integrated into many laboratory applications or expanded, and easily accessible worldwide.

A Study on the Insulation Methods of 220V Home Appliances and Wiring Devices (승압에 따르는 220V용 전기기기의 절연방식 결정에 관한 연구)

  • Sung Won Rhee
    • 전기의세계
    • /
    • 제20권4호
    • /
    • pp.5-11
    • /
    • 1971
  • This is a study on the insulation methods of home appliances and wiring devices proper to the new electric distribution system, primary side is 22.9/13.2KV, 3 phase 4 wire multigrounding system and secondary side is 380/220V, 3 phase 4 wire common neutral system. 1800V is determined as the electrical insulation voltage of the functional insulation because the abnormal voltage rise of the neutral line is 1300V. In the case of the functional insulation faults, the following safety methods will be suggested to protect the accidental faults: (a) class I appliance (accessible metal part is earthed), (b) class II appliance (doublly insulated), (c) class III appliance (operates at low voltage source). The mechanisms of the wiring devices are not improved to guarantee for the harmful electric shock but also the electrical insulation voltage is rised to 2000V.

  • PDF

Analysis of Electrical and Thermal Signal for Series Arc in Electrical Contact (전선의 접속부에서 직렬아크에 의한 전기적 및 열적 신호 분석)

  • Kim, Doo Hyun;Hwang, Dong Kyu
    • Journal of the Korean Society of Safety
    • /
    • 제30권5호
    • /
    • pp.1-7
    • /
    • 2015
  • This paper is aimed to analyze the electrical and thermal signal such as ignition possibility, ignition time, thermal characteristics and arc fault power that are associated with electrical fire in case of the occurrence of series arc at IV wiring used for interior wiring at commercial power source. In order to analyze the signal, series arc was induced by generating the constant vibration through vibrating device in the one phase (R phase) and ignition possibility was analyzed along the condition of current value by adding cotton material to the contact point of wiring. The ignition time is shortened as the electric current value increased, burning time is not associated with current value and the temperature rose up to $740^{\circ}C$ though it was not ignited. It was checked out that the temperature was the energy source enough that can generate the fire related with insulation aging of wiring and the inflammable. The possibility of electrical fire by series arc was shown as more than 12% at 5A, more than 42% at 20A and arc showed 27W at 5A, 180W at 20A. It was confirmed that the possibility of electrical fire exists at the condition as above and the circuit breaker did not operate. This data can be used as the reference value for the investigation of electrical fire or development of the circuit breaker.

A Study on Intelligent Technique for Correlation Application of Overcurrent and Leakage Current Signals in the Indoor Wiring (옥내배선에서 과전류와 누전 신호의 상관관계 적용을 위한 지능형 기법 연구)

  • Kim, Doo-Hyun;Kim, Eun-Jin;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • 제30권4호
    • /
    • pp.14-19
    • /
    • 2015
  • The purpose of this paper is to study the correlation application that electrical fire causes occurs for overcurrent and leakage current signals in the indoor wiring. In the order to purpose, the causes data of overcurrent, or leakage current of electrical fire are drawn out referring to past studies, consulting with experts and experimental data. The correlation application was then applied with fuzzy logic of intelligent technique. To check the reliability and performance of the correlation application, modified center of area(CoA) was adopted to calculate the possibility that electrical fire occurs, whose value was then compared to the results. The chance of electrical fire calculated is higher when two causes of fire are put into the CoA of the correlation application of this paper than that of when each cause is separately put into the CoA. The correlation application developed in this study enables better analysis on possible electrical fire due to overcurrent, or leakage current and provides managers with the possibility of electrical fire so that they can better manage at a time of overcurrent, or leakage current.

A Study of the Voltage drops computation program on multi-distributed random loads (다중 분산부하 전압강하산정 프로그램 연구)

  • Kang, Cha-Nyeong;Kwon, Sae-Hyuk;Cho, Sung-Pil
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.37-42
    • /
    • 2006
  • The voltage drop in electrical circuits causes a heat accumulation of wiring. This heat could change the specific character of an insulator and deteriorate the dielectric strength so that it could affect an electric leakage, an electric ant a power failure and a fire caused by the short circuit. Therefore optimal design for voltage drop in electrical wiring became an important factor to ensure the safety and economical efficiency of electrical facilities. So in this paper, I analyzed consequences that voltage drop affects in electrical wiring in multi-distributed system used for low electrical system such as road lights, Building, subway station which needs securities for the public society. And I proposed voltage drops computation program and optimal design to ensure the safety and economical efficiency.

  • PDF

Analysis of Resistive and Capacitive Leakage Current according to Wiring Type and Length at Cattle Barn (우사(牛舍)에서 전기배선의 종류와 길이에 따른 저항성 및 용량성 누전전류 분석)

  • Yoo, Sang-Ok;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • 제29권6호
    • /
    • pp.34-39
    • /
    • 2014
  • This paper is aimed to prevent danger of electrical fire at cattle barn to detect resistive and capacitive leakage current component for wiring type and length. In order to analysis for electric leakage component for cattle barn sizes and normal buildings, this paper was studied field state investigation which are at cattle barn companies(10 companies) in Cheong-won location and normal buildings at Nam-bu market in Jeon-ju location. Market to deduce the problems of electric leakage component is analyzed. The resistive and capacitive leakage current component for wiring type and length is analyzed at Beon-young cattle barn. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in cattle barn. It is acceptable for electrical equipment use in an cattle barn.

Analysis for the Thermal Properties of the Electrical Wire according to Overload and Disconnection (과부하 및 물리적 손상(반단선)에 의한 전선의 열적특성 해석)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • 제22권4호
    • /
    • pp.26-31
    • /
    • 2007
  • According to the statistical analysis on the electrical fire of 2005 years, most of electrical fire is generated from short circuit(4,985 cases), overcurrent(755 cases) leakage current(391 cases), poor contact(378 cases), disconnection(36 cases) on the electrical wiring device. The researches for the fire hazard about normal electric wiring have already been progressing in the advanced country such as USA and Japan, but Comparative study of the disconnection has not been conducted. Therefore, in this paper, we have simulated the thermal analysis for electrical wire according to deteriorating time in a normal state and disconnection with electrical wire using the electrical-thermal finite element method(Flux 3D). This paper acquire basis data of electricity fire signal by disconnection and wish to help for electrical fire cause diagnosis business.

A Study on the Development of Wiring Embody Lighting Appliance of Specifications (배선 일체화된 조명등기구의 작업지시서 개발에 관한 연구)

  • Choi, Chung-Seog;Koh, Jae-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제58권2호
    • /
    • pp.196-201
    • /
    • 2009
  • In this paper, We developed specifications light-way lighting appliance for efficient construction Wiring embody lighting appliance is convenient for divergence of circuit and arrangement construction of lamp. Also, it can be shortened construction period because series construction is available. Improved product is high work efficiency because the volume is small and the weight is light. Power line and line of communication are received each tray, so equipment is secure. We believe that the product is available for gallery, museum, and parking lot etc.

A Study of Wireless Harness Conveyor System (무선 하네스 컨베이어 시스템 연구)

  • Ryu, Hwan Gyu;Ryu, Jeong Gyu;Moon, SangooK
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.811-812
    • /
    • 2016
  • Wiring Harness is a medium that transfers the electrical signals necessary to drive a car, and receives a large impact on vehicle performance. Wiring Harness jobs in the workplace material relying on manual worker productivity is low product failure rate is high. Therefore, in this study in order to reduce repetitive humen error, indicated sequentially by the LED lights. We implement a high-performance wireless harness conveyor system.

  • PDF