• Title/Summary/Keyword: Electrical test

Search Result 7,379, Processing Time 0.043 seconds

Changes of Salt Concentration by the Height of Ground Water Table on Disused Saltpan for Golf Course Construction Site (골프코스를 조성할 폐염전 매립지의 지하수위에 따른 토양산도 및 전기전도도 변화)

  • Lee, Dong-Ik;Kim, Ki-Dong;Joo, Young-Kyoo
    • Asian Journal of Turfgrass Science
    • /
    • v.23 no.1
    • /
    • pp.143-150
    • /
    • 2009
  • High salt concentration is one of the most important limit factor on plant growth at a disused saltpan for golf course construction site. The control of salt in soil is definitely required and the monitoring of salt concentration in soil and ground water also required to amend soil physiochemical properties. This research was carried out to monitor the pH and salt concentration changes by the height of ground water. By the physiochemical analysis test, the soil contains a high salt concentration and classified as a slight alkaline clay soil. The height of ground water table changed to 1.3m, 3.3m and 2.8m at dry season(mid-late June, 2005), monsoon season(early-mid July) and after monsoon(late July), respectively. Compare to the average ground level of 2.9m, the ground water was over flooded about OAm at monsoon season. The electrical conductivity(ECe) was measured above $4.0dS{\cdot}m^{-1}$ over all areas and however, some areas showed over $20dS{\cdot}m^{-1}$. During a monsoon season, ECe was lowered to $1.2{\sim}15.0dS{\cdot}m^{-1}$, compared with those of the dry season. Therefore, the interception of the capillary connection between planting layer and ground water which contains high salt concentration should be adapted when golf courses are constructed on disused saltpan. The phytotoxicity caused by salt damage may be controled by the interception of capillary fringe of salt flow to the topsoil profile at the upper layer of the ground water table.

Optimization of Soldering Process of Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.7Cu-1.6Bi-0.2In Alloys for Solar Combiner Junction Box Module (태양광 접속함 정션박스 모듈 적용을 위한 Sn-3.0Ag-0.5Cu 및 Sn-1.0Ag-0.7Cu-1.6Bi-0.2In 솔더링의 공정최적화)

  • Lee, Byung-Suk;Oh, Chul-Min;Kwak, Hyun;Kim, Tae-Woo;Yun, Heui-Bog;Yoon, Jeong-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.3
    • /
    • pp.13-19
    • /
    • 2018
  • The soldering property of Pb-containing solder(Sn-Pb) and Pb-free solders(Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.7Cu-1.6Bi-0.2In) for solar combiner box module was compared. The solar combiner box module was composed of voltage and current detecting modules, diode modules, and other modules. In this study, solder paste printability, printing shape inspection, solder joint property, X-ray inspection, and shear force measurements were conducted. For optimization of Pb-free soldering process, step 1 and 2 were divided. In the step 1 process, the printability of Pb-containing and Pb-free solder alloys were estimated by using printing inspector. Then, the relationship between void percentages and shear force has been estimated. Overall, the property of Pb-containing solder was better than two Pb-free solders. In the step 2 process, the property of reflow soldering for the Pb-free solders was evaluated with different reflow peak temperatures. As the peak temperature of the reflow process gradually increased, the void percentage decreased by 2 to 4%, but the shear force did not significantly depend on the reflow peak temperature by a deviation of about 0.5 kgf. Among different surface finishes on PCB, ENIG surface finish was better than OSP and Pb-free solder surface finishes in terms of shear force. In the thermal shock reliability test of the solar combiner box module with a Pb-free solder and OSP surface finish, the change rate of electrical property of the module was almost unchanged within a 0.3% range and the module had a relatively good electrical property after 500 thermal shock cycles.

Effect of Acrylic Acid on the Physical Properties of UV-cured Coating Films for Metal Coating (금속코팅용 광경화 코팅필름의 물성에 대한 아크릴산(Acrylic acid)의 영향)

  • Seo, Jong-Chul;Choi, Jun-Suk;Jang, Eui-Sung;Seo, Kwang-Won;Han, Hak-Soo
    • Korean Chemical Engineering Research
    • /
    • v.49 no.1
    • /
    • pp.75-82
    • /
    • 2011
  • Five different composition UV-cured poly(urethane acrylate-co-acrylic acid) (PU-co-AA) films have been prepared by reacting isophorone diisocyanate(IPDI), polycaprolactone triol(PCLT), 2-hydroxyethyl acrylate(HEA), and different weight ratio trimethylolpropane triacrylate(TMPTA) and acrylic acid(AA) as diluents, and characterized using a Fourier transform infrared spectroscopy(FT-IR). The adhesion properties onto the stainless steel, morphology, mechanical hardness, and electrical property of UV-cured PU-co-AA films were investigated as a function of acrylic acid(AA) content. All the PU-co-AA films are structure-less and the molecular ordering and packing density decreased with increasing content of AA due to the flexible structure and -COOH side chains in AA. The crosscut test showed that PU-co-AA films without AA and with low content of AA showed 0% adhesion(0B) and the adhesion of PU-co-AA films in the range of 40-50% AA increased dramatically as the content of AA increases. The pull-off measurements showed that the adhesion force of PU-co-AA films to stainless steel substrate varied from 6 to 31 kgf /$cm^2$ and increased linearly with increasing AA content. The mechanical hardness also decreased as the content of AA increases. This may come from relatively linear and flexible structure in AA and low crystallinity in PU-co-AA films with higher content of AA. The higher AA-containing PU-co-AA films showed higher dielectric constant due to the increase of polarization by introducing AA monomer. In conclusion, the physical properties of UV-cured PU-co-AA films are strongly dependent upon the content of AA and the incorporation of AA in polyurethane acrylate is very useful way to increase the adhesion strength of UV-curable polymers on the stainless steel substrate.

Fabrication and Characterization of Transparent Conductive Film based on Bacterial Cellulose (Bacterial cellulose를 기반으로 하는 투명전도성막의 제조 및 특성평가)

  • Yim, Eun-Chae;Kim, Seong-Jun;Kee, Chang-Doo
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.766-773
    • /
    • 2013
  • A transparent film was fabricated based on bacterial cellulose (BC), BC has excellent physical strength and stability at high temperature and it is an environmental friendly flexible material. In order to improve the conductivity, silver nanowire (AgNW) and/or graphene were introduced to the BC membrane. The aspect ratio of the AgNW synthesized in this study was 214, with a length of $15{\mu}m$ and width of 70 nm. The higher aspect ratio improved the conductivity by reducing the contact resistance. The thermal and electrical properties of 7 types of films prepared were investigated. Each film was fabricated with rectangular shape ($2mm{\times}2mm{\times}50{\mu}m$). The films were scored with a net shape by a knife, and filled with AgNW and graphene to bestow conductivity. The film filled with AgNW showed favorable electrical characteristics with a thickness of $350{\mu}m$, electron concentration of $1.53{\times}10^{19}$, electron mobility of $6.63{\times}10^5$, and resistivity of 0.28. The film filled with graphene had a thickness of $360{\mu}m$, electron concentration of $7.74{\times}10^{17}$, electron mobility of 0.17, and resistivity of 4.78. The transmittances at 550 nm were 98.1% and 80.9%, respectively. All the films were able to light LEDs bulbs although their brightness differed. A thermal stability test of the BC and PET films at $150{\pm}5^{\circ}C$ showed that the BC film was more stable, whereas the PET film was quickly banded. From these results, it was confirmed that there it is possible to fabricate new transparent conductivity films based on BC.

Development of Anode-supported Planar SOFC with Large Area by tape Casting Method (테입캐스팅을 이용한 대면적 (100 cm2) 연료극 지지체식 평판형 고체산화물 연료전지의 개발)

  • Yu, Seung-Ho;Song, Keun-Suk;Song, Hee-Jung;Kim, Jong-Hee;Song, Rak-Hyun;Jung, Doo-Hwan;Peck, Dong-Hyun;Shin, Dong-Ryul
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.1
    • /
    • pp.41-47
    • /
    • 2003
  • For the development of low temperature anode-supported planar solid oxide fuel cell, the planar anode supports with the thickness of 0.8 to 1 mm and the area of 25, 100 and $150\;cm^2$ were fabricated by the tape casting method. The strength, porosity, gas permeability and electrical conductivity of the planar anode support were measured. The porosity of anode supports sintered at $1400^{\circ}C$ and then reduced in$H_2$ atmosphere was increased from $45.8\%\;to\;53.9\%$. The electrical conductivity of the anode support was $900 S/cm\;at\; 850^{\circ}C$ and its gas permeability was 6l/min at 1 atm in air atmosphere. The electrolyte layer and cathode layer were fabricated by slurry dip coating method and then had examined the thickness of $10{\mu}m$ and the gas permeability of 2.5 ml/min at 3 atm in air atmosphere. As preliminary experiment, cathode multi-layered structure consists of LSM-YSZ/LSM/LSCF. At single cell test using the electrolyte layer with thickness of 20 to $30{\mu}m$, we achieved $300\;mA/cm^2$ and 0.6V at $750^{\circ}C$

Variation of cyanobacteria occurrence pattern and environmental factors in Lake Juam (주암호 유해남조류 출현양상과 환경요인 변화)

  • Chung, Hyeonsu;Son, Misun;Ryu, Hui-Seong;Park, Chang Hee;Lee, Rury;Cho, Misun;Lim, Chaehong;Park, Jonghwan;Kim, Kyunghyun
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.640-651
    • /
    • 2019
  • The study analyzed the relationship between harmful cyanobacteria and physicochemical factors in Lake Juam from 2005 to 2018. The research locations were designated St. 1 (Juam-Dam) and St. 2 (Sinpyong). Harmful cyanobacteria was found in four genera (Microcystis sp., Anabaena sp., Aphanizomenon sp., Oscillatoria sp.). The average standing crops of harmful cyanobacteria in both locations were 2,575 cells mL-1 and 2,557 cells mL-1 from 2005 to 2011. Since 2012, there has been a significant decrease that the measurements were 42 cells mL-1 and 82 cells mL-1 from 2012 to 2018. To analyze the reason for the decrease in harmful cyanobacteria, Pearson's correlation and t-tests were performed on data collected during the summer period (June-September). Pearson's correlation showed a significantly positive correlation with total nitrogen(TN), outflow, and storage and a negative correlation with electrical conductivity. T-tests were conducted in two different periods and showed decreases in total nitrogen, electrical conductivity, and residence time. The average rainfall was decreased from 263.3 mm (2005-2011) to 219.9 mm (2012-2018) and total nitrogen was decreased from 0.912 mg L-1 (2005-2011) to 0.811 mg L-1 (2012-2018) and the same variability was seen in TP (total phosphorus). Therefore, it seems that the low-rainfall decreased the nutrients (TN) and variability in the TP, resulting in a decrease in harmful cyanobacteria in Lake Juam.

Preparation and Oxygen Permeation Properties of La0.07Sr0.3Co0.2Fe0.8O3-δ Membrane (La0.07Sr0.3Co0.2Fe0.8O3-δ 분리막의 제조 및 산소투과 특성)

  • Park, Jung Hoon;Kim, Jong Pyo;Baek, Il Hyun
    • Applied Chemistry for Engineering
    • /
    • v.19 no.5
    • /
    • pp.477-483
    • /
    • 2008
  • $La_{0.7}Sr_{0.3}Co_{0.2}Fe_{0.8}O_{3-{\delta}$ oxide was synthesized by a citrate method and a typical dense membrane of perovskite oxide has been prepared using as-prepared powder by pressing and sintering at $1300^{\circ}C$. Precursor of $La_{0.7}Sr_{0.3}Co_{0.2}Fe_{0.8}O_{3-{\delta}$ prepared by citrate method was investigated by TGA and XRD. Metal-citrate complex in precursor was decomposed into perovskite oxide in the temperature range of $260{\sim}410^{\circ}C$ but XRD results showed $SrCO_3$ existed as impurity at less than $900^{\circ}C$. Electrical conductivity of membrane increased with increasing temperature but then decreased over $700^{\circ}C$ in air atmosphere ($Po_2=0.2atm$) and $600^{\circ}C$ in He atmosphere ($Po_2=0.01atm$) respectively due to oxygen loss from the crystal lattice. The oxygen permeation flux increased with increasing temperature and maximum oxygen permeation flux of $La_{0.7}Sr_{0.3}Co_{0.2}Fe_{0.8}O_{3-{\delta}$ membrane with 1.6 mm thickness was about $0.31cm^3/cm^2{\cdot}min$ at $950^{\circ}C$. The activation energy for oxygen permeation was 88.4 kJ/mol in the temperature range of $750{\sim}950^{\circ}C$. Perovskite structure of membrane was not changed after permeation test of 40 h and the membrane was stable without secondary phase change with 0.3 mol Sr addition.

Urban archaeological investigations using surface 3D Ground Penetrating Radar and Electrical Resistivity Tomography methods (3차원 지표레이다와 전기비저항 탐사를 이용한 도심지 유적 조사)

  • Papadopoulos, Nikos;Sarris, Apostolos;Yi, Myeong-Jong;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.56-68
    • /
    • 2009
  • Ongoing and extensive urbanisation, which is frequently accompanied with careless construction works, may threaten important archaeological structures that are still buried in the urban areas. Ground Penetrating Radar (GPR) and Electrical Resistivity Tomography (ERT) methods are most promising alternatives for resolving buried archaeological structures in urban territories. In this work, three case studies are presented, each of which involves an integrated geophysical survey employing the surface three-dimensional (3D) ERT and GPR techniques, in order to archaeologically characterise the investigated areas. The test field sites are located at the historical centres of two of the most populated cities of the island of Crete, in Greece. The ERT and GPR data were collected along a dense network of parallel profiles. The subsurface resistivity structure was reconstructed by processing the apparent resistivity data with a 3D inversion algorithm. The GPR sections were processed with a systematic way, applying specific filters to the data in order to enhance their information content. Finally, horizontal depth slices representing the 3D variation of the physical properties were created. The GPR and ERT images significantly contributed in reconstructing the complex subsurface properties in these urban areas. Strong GPR reflections and highresistivity anomalies were correlated with possible archaeological structures. Subsequent excavations in specific places at both sites verified the geophysical results. The specific case studies demonstrated the applicability of ERT and GPR techniques during the design and construction stages of urban infrastructure works, indicating areas of archaeological significance and guiding archaeological excavations before construction work.

A Change of Stream Water Quality by Forest Types (임상에 따른 계류수의 수질변화에 관한 연구)

  • Ma, Ho-Seop;Kang, Won-Seok;Kang, Eun-Min
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.2
    • /
    • pp.142-148
    • /
    • 2011
  • This study was carried out to clarify the change characteristics of stream water quality by type of forest from June to August, 2009 in three stands (Castanea crenata, Pinus densiflora and Plantation Land) of Samgye-ri Naedong-myeon Jinju-si Gyeongsangnam-do. The pH of stream water in three stands was highest in Pinus densiflora (pH 7.18) followed by Castanea crenata (pH 6.90) and Plantation land (pH 6.90) while the electrical conductivity of stream water was highest in Plantation land followed by Castanea crenata stand and Pinus densiflora stand was the lowest. Cations contents of stream water in three stands were high in order of $Ca^{2+}$, $Na^{+}$, $Mg^{2+}$, $K^{+}$, and $NH_{4}{^{+}}$. But anions of stream water in Castanea crenata stand and Pinus densiflora stand were high in order of $SO_{4}{^{2-}}$, $Cl^{-}$ and $NO_{3}{^{-}}$ while those of stream water in Plantation land were high in order of $SO_{4}{^{2-}}$, $NO_{3}{^{-}}$ and $C\lambda^{-}$. The stream water in three stands was significant at pH, EC, $NO{^{3-}}$, $Ca^{2+}$, $Mg^{2+}$, $Na^{+}$, $Cl^{-}$, TNU and Color by duncan test. These results indicate that quality of stream water have a difference among three stands. The level of pH, $NH_{4}{^{+}}$, $Cl^{-}$, $SO_{4}{^{2-}}$ and $NO_{3}{^{-}}$ of stream water in three stands were within the domestic use standard for drinking water. but turbidity and color of stream water were more than that of domestic use standard for drinking water. Therefore, non-point sources like urban forest watersheds which are soil erosion and fertilizer application lands should be taken to the appropriate mitigation measures if they are to be used as source of drinking water.

The Effect of Carbon Dioxide Leaked from Geological Storage Site on Soil Fertility: A Study on Artificial Leakage (지중 저장지로부터 누출된 이산화탄소가 토양 비옥도에 미치는 영향: 인위 누출 연구)

  • Baek, Seung Han;Lee, Sang-Woo;Lee, Woo-Chun;Yun, Seong-Taek;Kim, Soon-Oh
    • Economic and Environmental Geology
    • /
    • v.54 no.4
    • /
    • pp.409-425
    • /
    • 2021
  • Carbon dioxide has been known to be a typical greenhouse gas causing global warming, and a number of efforts have been proposed to reduce its concentration in the atmosphere. Among them, carbon dioxide capture and storage (CCS) has been taken into great account to accomplish the target reduction of carbon dioxide. In order to commercialize the CCS, its safety should be secured. In particular, if the stored carbon dioxide is leaked in the arable land, serious problems could come up in terms of crop growth. This study was conducted to investigate the effect of carbon dioxide leaked from storage sites on soil fertility. The leakage of carbon dioxide was simulated using the facility of its artificial injection into soils in the laboratory. Several soil chemical properties, such as pH, cation exchange capacity, electrical conductivity, the concentrations of exchangeable cations, nitrogen (N) (total-N, nitrate-N, and ammonia-N), phosphorus (P) (total-P and available-P), sulfur (S) (total-S and available-S), available-boron (B), and the contents of soil organic matter, were monitored as indicators of soil fertility during the period of artificial injection of carbon dioxide. Two kinds of soils, such as non-cultivated and cultivated soils, were compared in the artificial injection tests, and the latter included maize- and soybean-cultivated soils. The non-cultivated soil (NCS) was sandy soil of 42.6% porosity, the maize-cultivated soil (MCS) and soybean-cultivated soil (SCS) were loamy sand having 46.8% and 48.0% of porosities, respectively. The artificial injection facility had six columns: one was for the control without carbon dioxide injection, and the other five columns were used for the injections tests. Total injection periods for NCS and MCS/SCS were 60 and 70 days, respectively, and artificial rainfall events were simulated using one pore volume after the 12-day injection for the NCS and the 14-day injection for the MCS/SCS. After each rainfall event, the soil fertility indicators were measured for soil and leachate solution, and they were compared before and after the injection of carbon dioxide. The results indicate that the residual concentrations of exchangeable cations, total-N, total-P, the content of soil organic matter, and electrical conductivity were not likely to be affected by the injection of carbon dioxide. However, the residual concentrations of nitrate-N, ammonia-N, available-P, available-S, and available-B tended to decrease after the carbon dioxide injection, indicating that soil fertility might be reduced. Meanwhile, soil pH did not seem to be influenced due to the buffering capacity of soils, but it is speculated that a long-term leakage of carbon dioxide might bring about soil acidification.