• 제목/요약/키워드: Electrical test

검색결과 7,379건 처리시간 0.034초

진공차단기용 전자식 보조접점 컨트롤러 개발 및 성능인증시험에 관한 연구 (A Study on the Development of Controller which is used Electric Operating Cell(EOC) for Vacuum Circuit Breaker and the Controller Performance Certification Test)

  • 이기선;박정철;추순남
    • 전기학회논문지P
    • /
    • 제64권3호
    • /
    • pp.130-137
    • /
    • 2015
  • This study is about the controller development of the Electric Operating Cell(EOC) which will replace the Mechanical Operated Cell(MOC) of the vacuum circuit breaker which has been used in the power plant and the performance test for the developed controller. The controller developed through this study was manufactured considering the harsh installation environment and electrical condition of the power plant, and the controller performance certification test for confirming the product reliability was taken to know whether or not to withstand fully in various electrical and mechanical problems. Items for performance certification test were AC power frequency voltage withstand test, combined surge immunity test, 1 [MHz] oscillatory SWC test, fast transient SWC test, radiated electromagnetic interference test, vibration test. As a result, all tests has passed an examination without malfunction.

고분자 피뢰기의 기밀특성에 관한 연구 (Sealing Integrity of polymeric ZnO Surge Arresters)

  • Liang, He-Jin;Han, Se-Won;Cho, Han-Goo;Kim, In-Sung
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.258-261
    • /
    • 1997
  • The sealing integrity is related to the safe operation of arrester the prime failure reason of porcelain housed arresters is moisture ingress. To be a meaningful tests a polymer arrester sealing test must be a realistic acceleration of field service. We think the test should be an accelerating course of actual temperatures, the enduring property to mechanical load and temperatures should be considered together. A union test method consisting of the thermal mechanical test and thermal cycling test is proposed to test the sealing integrity of polymeric arresters, which uses dielectric loss, leakage current 1mA DC voltage and partial discharge as the diagnostic techniques, and the test results were presented. The comparison states that the TMTCUT method is suitable fur the test of sealing integrity of polymeric arresters. .

  • PDF

피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구 (A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester)

  • 정기석;길형준
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

진동환경에 따른 전기설비의 내구성 향상에 관한 연구 (A Study on Endurance Improvement of Electrical Equipment according to Vibration Environment)

  • 박근석;심재명;이대동
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1146-1151
    • /
    • 2014
  • The equipment in ships and railway vehicles are continuously exposed to vibration, and its durability is very important. Therefore, consumers require the verification of the performance of equipment via standardized tests under the given environments to improve and stabilize the performance. In this study, a durability improvement and stabilization plan was proposed, which included the exploratory vibration test, variable frequency test and endurance test for the electrical equipment according to the vibration environment. It is expected that this study results will improve the technological competitive power of the ship and railway-related manufacturers and contribute to the equipment development and export.

자성 측정 방법에 따른 BLDC 전동기의 전자계 특성해석 (Finite Element Analysis of BLDC Motor Characteristic according to Magnetic Property Measurement Methods)

  • 김지현;하경호;권오열;차상윤;김재관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.697-698
    • /
    • 2008
  • This paper deals with finite element characteristic analysis of brushless DC motor according to magnetic property measurement methods. Magnetic property data for non-oriented (NO) electrical steel for electric motors are measured by the Epstein test which is considered as the international standards. Data from Epstein test may result in discrepancy from motor characteristic tests due to innate anisotropic property of NO electrical steel. Finite element analysis were performed for a BLDC motor by various measurement methods such as Epstein test, Ring test and single sheet test (SST), and calculated results were compared with considering anisotropic property conditions.

  • PDF

친환경 배전급 전력케이블용 절연재료의 전기적 특성에 관한 연구 (I) (A Study on Electrical Properties of Insulating Materials for Eco-friendly Distribution Power Cables (I))

  • 이준호;김철호;조영철;이문석
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.551-556
    • /
    • 2017
  • The cross-linked polyethylene(XLPE) has been most widely used for the power cable insulating layer because of its outstanding properties such as electrical and mechanical properties. However, XLPE is unrecyclable when disposed after replacement and demolishing because it becomes thermosetting through cross-linked process. Recently, because of growing social awareness of recycling and eco-friendly, there is growing need for the development of recyclable insulating materials that can replace XLPE. Therefore, the purpose of this study is to compare the electrical properties of XLPE and recyclable thermoplastic insulating materials. To this end, we compared and analyzed the electrical properties of XLPE and group N2 through AC breakdown test, accelerated water treeing test and accelerated life test(ALT).

전선의 도체조직 분석에 의한 전기화재 감식 (Electrical Fire Identification due to Conductor Structure Analysis of Electrical Wires)

  • 박오철;김왕곤;박남규;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.615-618
    • /
    • 2003
  • To investigate the electrical fire identification due to conductor structure analysis of an electrical wire, we are studied by temperature heating test, over current test, short test and electric molten marks. And metal structure analysis of wire by short, we are found out increase in crystal grain with heating temperature. Structure of specimen at over current 300[%] occurred hardly structure formation and boundary of grain.

  • PDF

PE 계열 절연재의 내트래킹 성능 평가 (A Tracking Test for PE Series Insulations)

  • 정종욱;정진수;이건호;박하용;김남석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.154-155
    • /
    • 2006
  • This paper describes a tracking test results for the organic polymers with PE(polyethylene) series by a declining method. After processing the 4 PE series insulations with different density, the tracking duration for each was measured and compared with that for ABS(acrylonitrile butadiene styrene). The surface condition of each specimen was carefully observed after the tracking test. As a result, HDPE showed excellent performance in tracking test.

  • PDF

Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul;Kim, Jae Ho
    • Safety and Health at Work
    • /
    • 제11권4호
    • /
    • pp.405-417
    • /
    • 2020
  • Background: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. Methods: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets' conductor surface and content, insulator weight, and thermal deformation temperature. Results: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 ℃. In relation to the installation year (30 years), insulation resistance decreased from 70 ℃, which is as much as 40 ℃ lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. Conclusion: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 ℃ of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 ℃. It is necessary to manage electrical socket outlets that have been installed for a long time.

저압용 전기전자기기에 부분방전시험의 적용을 위한 기초연구 (A Basic Study on the Application of Partial Discharge Test on Low-voltage Electrical and Electronic Devices)

  • 길경석;송재용;문승보;차명수;황돈하;강동식
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.586-590
    • /
    • 2006
  • This paper deals with the application of a partial discharge (PD) test on low-voltage electrical and electronic devices, which is recently being accepted as a non-destructive and a effective dielectric test method. A comparative analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards was carried out on low-voltage insulation transformers. The results showed that the WVT causes insulation degradation of the specimen during the test by applying high voltage. However, the PD test can be performed in ranges from 30 % to 50 % of the test voltage specified in the WVT. Therefore, the PD test is successfully applicable for a non-destructive test method on low-voltage electrical and electronic devices as a replacement of the WVT.