• Title/Summary/Keyword: Electrical shock

Search Result 405, Processing Time 0.021 seconds

보혈안신탕(補血安神湯), 가미보혈안신탕(加味補血安神湯)의 항(抗) stress효과(效果)에 관(關)한 실험적(實驗的) 연구(硏究)

  • Lee Dong-Jin;Kim Ji-Hyeok;Hwang Ui-Wan
    • Journal of Oriental Neuropsychiatry
    • /
    • v.4 no.1
    • /
    • pp.77-97
    • /
    • 1993
  • Human and animals are living by acclimation to environmental changes like high and cold temperature, nose, confinement, etc. If the above changes reach a defined levels, some physiological abnormal state could appear, which we call them as stress state. Catecholamines are excreted by the sympathetic-adrenomedullary system in free from in urine. Catecholamines are derived from the adrenal medulla and urinary epinephrine can be taken as a rough estemation of the activity of this gland. Many scientist reported the endocrinological change, excretion of catecholamine and its metabolites, stomach ulcer formation, etc. under the condition of the confinement and high temperature. In this study author gave restraint, electric shock and immersion stress to rats by administrating by HPLC and got the following results. 1. In the restriant experiment, epinephrine contents in control rat was 194.7 ng, but in Bohyulanshintang administered rat urine 198.9 ng of epinephrine was found. 2. In the electrical shock experiment, 199.5 ng of epinephrine was found in the control rat urine, but in Bohyulanshintang administered rat urine epinephrine content was 142.4 ng. 3. Dopamine contents in control rat urine the immersion environment was 118.9 ng, but in Bohyulanshintang administered rat urine only 55.2 ng of dopamine was found. 4. Incontrol rat stomach there appeared focal erosion and inflamatory exudate, but in experimental group these symptom were turned to mild condition.

  • PDF

The Development of Acupuncture- Moxibustion Device for 4 points around GV20(Baihui) (백회와 사신총 혈위에 적합한 침구 소자의 개발)

  • Jo, Bongkwan
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.19 no.2
    • /
    • pp.101-108
    • /
    • 2015
  • Objectives This paper focused on developing the acupuncture-moxibustion device for head. Disadvantages of the existing devices for head moxibustion are its hume and inconvenience in operating because of the hair. Methods The proposed acupuncture-moxibustion device for GV20(Baihui) is 10mm long as needle body and 6mm long as needle root whose feature are 1~2 turns spiral coil. The spiral coil contains the moxa in order not to drop the moxa while operating Results The direct temperature on the burning moxa were measured by TK-305 infrared thermometer. But the direct temperature on the needle of acupuncture-moxibustion device were not able to measure by TK-305 infrared thermometer. By definition equation, the indirect temperatures on the needle of acupuncture-moxibustion device were able to be calculated. Conclusion A very safe, small and cheap acupuncture-moxibustion device for GV20(Baihui) of head is proposed. It will be useful to generate the heat shock protein and to operate in preventing and curing the Alzheimer's disease.

A Study of Joining Method of BSCCO(2223) Tape (BSCCO(2223) 초전도 선재의 접합공정 연구)

  • 김정호;김중석;김태우;지붕기;주진호;나완수
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.1-7
    • /
    • 1999
  • we evaluated the effects of joining process such as contact method. shape of joined area and pressure on the electrical and mechanical properties of Bi-2223 superconducting tape, Specifically. the current capacity of the jointed tape was measured as a function of uniaxial pressure. and the thermal shock, bonding strength and the thermal of the tape were evaluated and correlated to the microstructural evolution. It was observed that the current capacity was significanrly dependent on the uniaxial pressure The jointed tape, fabricated with a pressure of 1,000-1,600 Mpa. showed the highest value of current capacity results from improvements in core density, contacting area and grain alignment, ect. In addition, the strength of jointed tape was measured to be 86 Mpa, which is about 88% of the unjoined ape's strength. The irreversible strain($\varepsilon$irrev) for the jointed tape was measured to be 0.1%, smaller than that of unjoined tape ($\varepsilon$irrev= 0.3%). The decrease in the strength and irreversible strain for jointed tape is believed to be due to the irregular geometry/morphology of the transition area of the tape.

  • PDF

Over-expression of OsHsfA7 enhanced salt and drought tolerance in transgenic rice

  • Liu, Ai-Ling;Zou, Jie;Liu, Cui-Fang;Zhou, Xiao-Yun;Zhang, Xian-Wen;Luo, Guang-Yu;Chen, Xin-Bo
    • BMB Reports
    • /
    • v.46 no.1
    • /
    • pp.31-36
    • /
    • 2013
  • Heat shock proteins play an important role in plant stress tolerance and are mainly regulated by heat shock transcription factors (Hsfs). In this study, we generated transgenic rice over-expressing OsHsfA7 and carried out morphological observation and stress tolerance assays. Transgenic plants exhibited less, shorter lateral roots and root hair. Under salt treatment, over-expressing OsHsfA7 rice showed alleviative appearance of damage symptoms and higher survival rate, leaf electrical conductivity and malondialdehyde content of transgenic plants were lower than those of wild type plants. Meanwhile, transgenic rice seedlings restored normal growth but wild type plants could not be rescued after drought and re-watering treatment. These findings indicate that over-expression of OsHsfA7 gene can increase tolerance to salt and drought stresses in rice seedlings.

Planar Laser-Induced Fluorescence (PLIF) Measurements of a Pulsed Electrothermal Plasma Jet

  • Kim, Jong-Uk;Kim, Youn J.;Byungyou Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1808-1815
    • /
    • 2001
  • The characteristics of a pulsed plasma jet originating from an electrothermal capillary discharge have been investigate using laser-induced fluorescence (LIF) measurement. Previous emission measurements of a 3.1 kJ plasma jet show trial upstream of the Mach disk the temperature and electron number density are about 14,000 K and and 10$\^$17/ cm$\^$-3/, while downstream of the Mach dick tole values are about 25,000 K and 10$\^$18/ cm$\^$-3/, respectively. However, these values are barred on line-of-sight integrated measurements that may be misleading. Hence, LIF is being used to provide both spatially and temporally resolved measurements. Our recent work has been directed at using planar laser-induced fluorescence (PLIF) imaging of atomic copper in the plasma jet flow field. Copper is a good candidate for PLIF studies because it is present throughout the plasma and has electronic transitions that provide an excellent pump-detect strategy. Our PLIF results to date show that emission measurements may give a misleading picture of the flow field, as there appeals to be a large amount of relatively low temperature copper outside the barrel shock. which may lead to errors in temperature inferred from emission spectroscopy. In this paper, the copper LIF image is presented and at the moment, relative density of atomic copper, which is distributed in the upstream of the pulsed plasma jet, is discussed qualitatively.

  • PDF

A Study on Reliability Assessment of Ag-free Solder (무은 솔더의 신뢰성 평가에 관한 연구)

  • Kim, Jong-Min;Kim, Gi-Young;Kim, Kang-Dong;Kim, Seon-Jin;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.13 no.2
    • /
    • pp.109-116
    • /
    • 2013
  • The solder is any of various fusible alloys, usually tin and lead, used to join metallic parts that provide the contact between the chip package and the printed circuit board. Solder plays an important role of electrical signals to communicate between the two components. In this study, two kinds of Ag-free solder as sample is made to conduct the thermal shock test and the high humidity temperature test. Low resistance is measured to estimate crack size of solder, using daisy chain. The low speed shear test is also performed to analyze strength of solder. The appropriate degradation model is estimated using the result data. Depending on the composition of solder, lifetime estimation is conducted by adopted degradation model. The lifetime estimated two kinds of Ag-free solder is compared with expected lifetime of Sn-Ag-Cu solder. The result is that both Ag-free composition are more reliable than Sn-Ag-Cu solder.

Characteristic Analysis and Configuration of the Protection System to Improve the Safety of the BIPV System (BIPV 시스템의 안전성 향상을 위한 보호시스템 구성 및 특성 분석)

  • Seok-Hwan Cho;Jae-Sub Ko;Dae-Kyong Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.591-599
    • /
    • 2024
  • This paper presents the configuration and characteristic analysis of the protection system to improve the safety of the building integrated photovoltaic(BIPV) system. BIPV is a solar power system installed in buildings. Since the BIPV system is installed in buildings, there is a high risk of electric shock and fire accidents. Therefore, in order to improve the safety of BIPV, a protective system is required to block or quickly detect risk factors. In this paper, as a protection system to improve the safety of the BIPV system, it is composed of a rapid shutdown (RSD) that can quickly separate the PV system to prevent fire and electric shock accidents and a system to detect Arc faults that cause PV system fires. RSD and Arc Fault Detector analyzed the operating characteristics according to each condition and confirmed that the safety of the BIPV system can be improved through this.

Hazards and Solutions of Loss of the PEN Conductor in TN-C-S System (TN-C-S계통에서 PEN도체의 단선고장의 위험성 및 보호대책)

  • Lee, Bok-Hee;Lee, Kyu-Sun;Ahn, Chang-Hwan;Kim, Han-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.113-120
    • /
    • 2007
  • This paper presents the electric shock hazards and solutions of loss of the combined protective and neutral (PEN) conductor in TN-C-S system. In order to mitigate the touch voltage on exposed-conductive-parts in a break in the PEN conductor, the touch voltages on exposed-conductive-parts in a break in the PEN conductor were experimentally investigated as a function of the ground resistances of the source grounding electrode and customer's additional grounding electrode. As a result, the equipotential bonding is one of important requirements for installations supplied by TN-C-S system. A solution of mitigating the touch voltages on exposed-conductor-parts caused by a loss of the PEN conductor would be the installation of the additional grounding electrode at the customer's service entrance. The ground resistance of additional grounding electrode necessary to limit the touch voltage to a safety voltage of less than 50[V] depends on the load and circuit parameters. In addition, the undervoltage sensing devices oner affordable solutions to detect a loss of the PEN conductor in TN-C-S system.

Effects of Electroacupuncture on Immune Function (전기침이 면역증진에 미치는 효과)

  • Kang, Se-Young;Jeong, Eun-Woo;Lee, Sang-Kwan;Sung, Kang-Keyng
    • Journal of Acupuncture Research
    • /
    • v.24 no.6
    • /
    • pp.29-36
    • /
    • 2007
  • Electroacupuncture(EA) is known to affect various autonomic functions such as blood pressure regulation, immune modulation and the improvement of disorders concerning autonomic functions. The aim of the present study was to establish whether EA has an immune-enhancing effect. ICR mice weighing 20 to 25g were divided into four groups: Group I(n=6), blank; Group II(n=6), control; Group III(Zusanli, n=6), low frequency-EA(10Hz of electrical stimulation), and Group IV(Zusanli, n=6), high frequency-EA (100Hz of electrical stimulation). For this study, we investigated expressions of spleen heat shock protein (HSP)70, HSP90 and secretions of cytokines. A Forced Swimming Test(FST) was performed as a model of activity test in mice. After three days of the FST, 10Hz EA($114.8{\pm}7.27s$) and 100Hz EA($147.5{\pm}1.29s$) immobility time significantly decreased compared with the control group($157.2{\pm}1.48s$). After seven days, 10Hz EA($124{\pm}1s$) and 100Hz EA($141{\pm}4.24s$) also significantly decreased immobility time compared with the control group($168{\pm}7.93s$). 10Hz EA and 100Hz EA increased the expression of HSP70 but did not change that of HSP90. 100Hz EA increased secretions of IL-6 and IL-12 compared with the control group however, 10Hz EA failed to change those of IL-6 and IL-12. The present results suggest that EA may be useful for down-regulated immune diseases.

  • PDF

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.