• Title/Summary/Keyword: Electrical safety system

Search Result 1,370, Processing Time 0.028 seconds

A Study on Safety Assessment of CTC/EI Interface (열차집중제어장치와 전자연동장치 인터페이스의 안전성평가에 관한 연구)

  • SHIN Seok-kyun;LEE Key-seo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.7
    • /
    • pp.309-316
    • /
    • 2005
  • In this paper we analyzed a dangerous failure and a safety requirement based on HIA (Hazard Identification and Analysis) of an interface model between CTC (Centralized Traffic Control) system and El (Interlocking) system, and assigned SU (Safety Integrity Level) by way of an risk estimation of the interface, which employed PHA (Preliminary Hazard Analysis) for the interface of the track control system, being managed as separated system between the centralized traffic control system and the interlocking system, An estimation which satisfies a safety reference of the international standard has been achieved through a quantification of the system failure rate and the dangerous failure rate of the interface model.

Development of Electric Safety Monitoring System and Cabinet Panel for Traditional Markets (재래시장 상가 분전반 및 전기안전감시시스템 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Suk-Myong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.123-128
    • /
    • 2010
  • In this paper, in order to reduce the electric disaster damage which is caused by with electric equipment of traditional markets, we developed cabinet panel and the electric safety monitoring system which is able to monitor the electrical equipments condition(over current, leakage, arc, WH, electrical fire factor etc.) at traditional markets. We constructed Test-bed for testing reliability of electric safety monitoring system and the actual condition investigation about electrical equipment of traditional market. This paper will be used with the data for an actual demonstration project after reinforcing problems which are occurred to operation of traditional market actual loads.

Design of Successive Safety Light Curtain System Using Single Chip Microprocessor (단일칩 마이크로 프로세서로 구현한 연속 차광 감지 시스템의 설계)

  • Park, Chan-Won;Lee, Young-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3233-3235
    • /
    • 1999
  • This paper describes development of a microprocessor-based optoelectronic guard system established a higher level of control reliability in machine guard design. The system uses the design concept of diverse redundancy and a fast software algorithm. We have accomplished an safety light curtain system that allows to be intentionally disabled moving machine by the interrupt of dangerous situations. As a result, it is showed that the proposed system is effective enough to practical applications.

  • PDF

A Safety Assessment of a Mesh Grounding System for 22.9kV Substations (22.9kV 수전설비 Mesh 접지설계의 안전성 평가 사례)

  • Park, Sang-Gyo;Choi, Chang-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.54-60
    • /
    • 2013
  • There is increasing demand for practical groundings for small-area substations because of the recent revision of Korea's Electrotechnical Regulations, which necessitates the method of evaluating their safety. This paper proposes a practical mesh grounding system for 22.9kV substations and studies how to evaluate its safety. The proposed grounding system is proved to obey the safety criteria of ANSI/IEEE Std. 80 via ANSI/IEEE Std. 80 method and computer simulation.

Construction of a knowledge-base for safety standards to support the design of household electrical appliances (가전제품의 설계지원을 위한 안전규격 지식베이스의 구축)

  • Lee, Hyo-Seop;Han, Soon-Hung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.4
    • /
    • pp.106-113
    • /
    • 1994
  • Household electrical appliances should be designed to satisfy safety standards. An expert system is implemented to support the design process. The general-purpose expert system shell. ART-IM which is running under MS-DOS environment, is used to construct the knowledge-base. A set of rules has been extracted from the EN 60 335-1 that is British standard specification for the safety of household and similar electrical appliances. The main focus of this paper is on codes that have systematic and mormative structures. The internal structure of the safety standard is analysed to improve the process of rule extraction.

  • PDF

The Properties of Breakdown and Test for Resistance to Cracking of Power Cable for PL Countermeasure (PL법 대응을 위한 전력케이블의 열 충격 및 절연파괴 특성)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.349-352
    • /
    • 2007
  • It is impossible to database(DB) the patterns of cable events and cause analysis of faulted cable because the product liability(PL) law have been enforced in Korea, since 2002. In additions, simulation and pattern of cable events are needed for DB system under accelerated deterioration. In this paper, we tested for resistance to nicking of cable below the 22.9kV class due to thermal stresses. This method of exam is following IEC 60811-3-1(Common test methods for insulating and sheathing materials of electric cables). First of all, set the cable in the thermal stress instrument, temperature changed from -20 degree to 120 degree. After thermal stress, we observed a surface crack of cable through microscope and carried out AC withstand voltage test.

  • PDF

A Change of Surface Structure with Insulation Cover and Outdoor Cross-linked Polyethylene Insulated Wire Degraded by Salt Water (염수에 의해 열화된 절연커버 및 옥외용 가교폴리에틸렌 절연전선의 표면구조변화)

  • Choi, Chung-Seog;Gil, Hyoung-Jun;Kim, Hyang-Kon;Han, Woon-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1897-1899
    • /
    • 2004
  • In this paper, in order to analyze the characteristics of degradation by salt water with insulation cover and OC wire(outdoor cross-linked polyethylene insulated wire) used in power receiving system, an experimental apparatus has been designed and fabricated. An insulation cover and OC wire were installed in an experimental apparatus, and degraded in each case of 2%, 5%, 10% salinity during 12 weeks. An optical microscope was used to observe a changing process of sample surface, and an electrical safety was analyzed by measuring dielectric breakdown voltages of samples. As salinity increased, so ununiformity of sample surface increased. The breakdown wasn't produced to 50kV about samples regardless of salinity, testing period.

  • PDF

Preliminary Hazard Analysis of the ATC System for Electrical Hazards (전기적 위험요인에 대한 열차제어시스템의 예비위험요인분석)

  • Joung E. J.;Kim J. K.;Shin D. H.;Kim B. H.;Lee J. W.;Kim Y. M.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1415-1417
    • /
    • 2004
  • The system safety must be ensured before customization. There was no specific requirement representing system safety in Korea until now. So we should draw safety requirements to guarantee system safety for the first time. In this paper. the hazard identification and analysis to derive the safety requirements on the train control system are carried out. To analyze hazard, we have to deduce system functions. identify related hazards, derive the effects of the hazards, analyze current risks. define the target risks of the system, and deduce the alternative plans to reduce the effects of the hazards. For the case study, Preliminary Hazard Analysis(PHA) of the Automatic Train Control (ATC) System for Electrical Hazards are carried out.

  • PDF

The Fire Hazard of Screwed Electric Contacts Due to Mechanical Vibration at Low Voltage Equipment

  • Choi, Chung-Seog;Kim, Young-Seok;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.18-23
    • /
    • 2005
  • There are many electrical connections in the electric apparatus and most fires due to a fault contact result from a failure or misuse of electric apparatus and installation. The fault contact happens between electrical connections by the loose and the mechanical vibration. In this paper, we have investigated thermal and electrical properties of screwed electric contacts due to the mechanical vibration. The exciter was connected to a signal generator and power amplifier that provided the vibration frequency and amplitude. The vibration, temperature and voltage data were sent to a data acquisition system (DAQ). In the case that fault contact took place, the arc happened between the screwed electric contact and electric wire, heat due to the arc was transmitted to the adjacent insulators, for which the oxide could be generated more. In addition, a spark was generated and the insulator began to melt. Thus, the possibility of electrical fire became the highest in this case. Finally, when the fault contact takes place due to vibration, the hazard of an electric accident is very high.

A Study on the Insulation Resistance Measurement Technique for Electrical Safety of Green Car (친환경자동차의 전기안전을 위한 절연저항 측정에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon;Moon, Hyun-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.597-601
    • /
    • 2009
  • Green car such as a hybrid electrical vehicle and fuel cell vehicle is developed as a commercial target. UN/ECE/WP29 is developing GTR of HFCV and establishing the regulation and standard of electrical safety by ELSA. The regulation and standard about Electrical safety of vehicle are prescribed in ISO, UN/ECE, FMVSS, Japanese Attachment and so on, in case of insulation resistance is referred to keep more than 100/Vdc, 500/Vac. However, accurate method to measure insulation resistance agreeable to structure of vehicle does not exist now, it is actually that correctness of measurement drops according to the feature of battery and fuel cell stack. In this paper, the method to measure insulation resistance for protection against electrical shock by direct contact or indirect contact in Green Car will be indicated by making a comparison between the insulation measurement in standard of electrical safety and the experiment results for HEV and HFCV.