• Title/Summary/Keyword: Electrical safety standards

Search Result 203, Processing Time 0.03 seconds

A study on the safety LED lamp using internal control gear as the alternative type of fluorescent lamp (형광램프 대체 컨버터 내장형 LED램프의 안전성 확보방안)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.30-38
    • /
    • 2015
  • As products using LEDs are developed actively, also there has been large request for LED products that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there is no proper standard that manufacturer can use and test it. As a result manufacturer can't develop retrofit LED lamps and sell it even they have technology. In this study, by analyzing control gear for fluorescent lamp that is currently used in market which is magnetic or electronic ballast, I'd like to develop proper test method by investigating compatibility between all-type control gear and LED retrofit products.

A Study on the Insulation Characteristics of LED Lamps for Load and Street Lighting (LED 가로등 및 보안등기구의 절연특성 연구)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.546-551
    • /
    • 2009
  • In this paper, we studied insulation characteristics of LED lamps for load and street lighting. LED lamps can be divided into internal type and external type according to converter type. In this study, we analyzed technology standard, K(Electrical Appliances Safety Standards) and KS(Korean Industrial Standards) about insulation resistance for LED lamps for load and street lighting, and measured insulation resistances for each measured point. Mostly, insulation resistances were measured high more than regulation value but some measured points were measured badly. We expect that the results of these experiments would be helpful for electrical safety of LED lighting installation, manufacture, construction and maintenance.

A Study of Ground System improvement on Isolated Power Generation (독립 전원설비에서의 접지방법 개선에 관한 연구)

  • 류보혁;남택주;김정훈
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.96-102
    • /
    • 2001
  • In construction sites, portable generators and electrical equipments cause frequently electrical accidents due to the poor condition of their usage. However, there are very few technical guidelines on these equipments even though they have serious accident causing potentiality. In order to reduce such accidents in practical and economical, grounding methods are studied in this paper as the countermeasure of electrical accidents. Several Korean national standards and international standards regarding three grounding types are compared each other, and some prevention means of electrical accidents are reviewed in this study. This paper presents the most effective grounding methods by assuming the WCS with the isolated power systems.

  • PDF

Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current (누설전류로 인한 전기화재 및 감전사고 예방기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Kim, Jae-Hyun;Kang, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

Overhead Crane Controllers and Ergonomic Problems in Industrial Field (산업현장의 천장크레인 조작장치 사용 현황과 인간공학적 문제점)

  • Park, Jae Hee;Kim, Seung Hee
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.90-97
    • /
    • 2017
  • Overhead cranes are the most widely used and have been identified as one of the main causes of fatal accidents. Although structural, mechanical and electrical safety standards for overhead cranes have been established to some extent, ergonomic standards related to crane controllers are rarely established. As a result, many crane accidents are reported to be caused by operator's error. To investigate the actual use of crane controllers in the industrial field, we surveyed 82 overhead cranes in 15 workplace and interviewed workers operating them. This study has presented the ergonomic problems related to the crane controllers in the field. As a result of investigation, it was found that the direction control signs, the sign language, and the button layout on the pendant switches and remote controllers are not standardized, which can cause a human error. To reduce human errors in overhead crane operation, ergonomic standards for controllers should be reflected on the government legislation or standards.

Assessment of Equipotential Bonding and Electrical Continuity in Buildings (건축물의 등전위 본딩 및 전기적 연속성 평가)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.385-386
    • /
    • 2009
  • This paper deals with assessment of equipotential bonding and electrical continuity in Buinding by investigation on the spot at construction site. The assessment was carried out for continuity of steelwork in reinforced concrete structure, bonding conductor, protective conductor. A new grounding system based on international standards includes unity grounding system, structure grounding utilizing steel reinforced concrete, equipotential bonding, use of surge protective device.

  • PDF

A Study on counterplan and safety state research of substation at flood area (수.변전설비의 안전실태 조사 및 대책 연구)

  • Bae, Seok-Myung;Kim, H.S.;Kim, K.H.;Bang, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.47-52
    • /
    • 2005
  • lt's a general tendency that electrical facilities of power station become a large size and increase in number because electrical facilities become big and complicated with internal industrial development and economic growth. So, electrical accidents were increased in this electrical facilities of power station. Therefore, we studied on the safety environment in power station and compared of internal and external standards. So this paper gives information which is applied to install the electrical facilities and Prevents measures against electrical accidents.

  • PDF

The Conformity of Korean Railway Standards with International Standards : Automatic Coupler (한국철도표준규격 국제규격 부합화 : 자동연결기)

  • Kim, Jeong-Guk;Lee, Chang-Young;Seo, Jung-Won;Kwon, Sung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.213-218
    • /
    • 2009
  • The Korean railway standards (KRS), formerly managed by Korea Railroad (Korail), have been managed by the Korean Ministry of Land, Transport and Maritime Affairs (ML TM). According to Korean railway safety law and its ordinances, which were established for the guarantee of railway safety, the management of KRS including enactment and revision of technical standards for railway vehicle and components, was committed to Korea Railroad Research Institute (KRRI). Currently, a total of 195 standards has been managed from the various railway applications including track, electrical, and vehicle areas. Moreover, according to the guideline on the management of KRS, the conformity of KRS with international standards is encouraged for the enlargement of international trade. In this investigation, a brief management activity of KRS and the recent activities on conformity of KRS with AAR standards on automatic coupler will be introduced.

  • PDF

Secondary Optics Design of Dissymmetrical Light Distribution for 100 W LED Safety Luminaires (100 W급 LED 보안 등기구용 비대칭 배광의 2차 렌즈 설계)

  • Shin, Ik-Tae;Yang, Jong-Kyung;Lee, Dong-Jin;Par, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.6
    • /
    • pp.471-476
    • /
    • 2010
  • This paper has studied dissymmetrical light distribution design using the secondary optics in the simulation. fundamental Lambertian radiation distribution based on LED has been cut off by the secondary optics, and the first surface slope of lens and second surface slope of total reflection area have been calculated through formula. PMMA (the index of refraction: 1.49361) which is material of lens has been selected. critical angle($42.02993^{\circ}$) between Air and PMMA has been calulated by snell's law, and total reflection angle slope has been selected about $16.67^{\circ}$ to occur the total reflection. when the first surface slope and the second surface slope has been set up, Rays of all total reflection area have generated the total reflection. finally, designed LED Module has been estimated by Korean Industrial Standards for LED safety street lighting. dissymmetrical light distribution have been analyzed with reached effect of road illuminance, and average road illuminance which are each 70.6 lx, 40.35 lx, and 25.88 lx have been satisfied with Korean Industrial Standards for LED safety street lighting.

The Material Analyses and the Behavior Characteristics according to RCD Discloser (누전차단기 폭로에 따른 동작 특성 및 재료 분석)

  • Han, Woon-Ki;Kim, Hyang-Kon;Gil, Hyung-Jun;Lee, Ki-Hyun;Choi, Chung-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2019-2021
    • /
    • 2005
  • This paper describes the cut off time and the current characteristics of virgin RCDs and deteriorated ones in the seashore. The RCDs(Residual Current Protective Devices) are used for protecting the human body from electrical shock and for preventing facility accidents. According to the Korean standards, the RCDs are installed in panel boards. When RCDs are installed outside, they must be enclosed inside waterproof cases. In the case that RCOs are employed at temporary power sites and electrical facilities on the road, they are exposed to the external environment. As a result, the RCDs deteriorated in the seashore for 3 months showed high failure rate, while the virgin RCDs all complied with Korean Standard. Considering that the RCDs are used under exposed condition outside, the reliance of RCDs must be ensured by modifying the related regulations and codes and by developing Improved models advanced in their performance.

  • PDF