• 제목/요약/키워드: Electrical network analysis

검색결과 1,274건 처리시간 0.037초

계통운영시스템 계통해석 프로그램 정확도 향상에 관한 연구 (A Study on the Enhancement of Accuracy of Network Analysis Applications in Energy Management Systems)

  • 조윤성
    • 조명전기설비학회논문지
    • /
    • 제29권12호
    • /
    • pp.88-96
    • /
    • 2015
  • This paper describes a new method for enhancing the accuracy of network analysis applications in energy management systems. Topology processing, state estimation, power flow analysis, and contingency analysis play a key factor in the stable and reliable operation of power systems. In this respect, the aim of topology processing is to provide the electrical buses and the electrical islands with the actual state of the power system as input data. The results of topology processing is used to input of other applications. New method, which includes the topology error analysis based on inconsistency check, coherency check, bus mismatch check, and outaged device check is proposed to enhance the accuracy of network analysis. The proposed methodology is conducted by energy management systems and the Korean power systems have been utilized for the test systems.

시간 지연을 포함한 네트워크 시스템의 안정도 분석 (Stability Analysis of Network Systems with Time delay)

  • 김재만;최윤호;박진배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1674-1675
    • /
    • 2007
  • This paper presents a stability analysis of network systems with time delay. Time delay problem frequently occurs in network systems. Since it makes network systems unstable and unpredictable, an optimal controller is necessary to network systems. We prove the asymptotical stability of time delayed network systems using LMI optimization method and appropriate Lyapunov-Krasovskii functionals. Simulations show the effectiveness of the method.

  • PDF

전기·전자산업의 중간재 글로벌가치사슬 네트워크 구조와 중심성 분석 (Network Structure and Centrality Analysis of Global Value Chains in Electrical and Electronic Industries)

  • 김석민
    • 무역학회지
    • /
    • 제46권1호
    • /
    • pp.113-134
    • /
    • 2021
  • This study analyzed the centrality of the GVCs network and the value-added-based production structure of the electrical and electronic industries using ADB-MIRO and social network analysis methods. According to the analysis, the centrality and power of the GVSc intermediate goods network were differentiated into China, the United States, and the EU due to the advancement of industrial structure in Asia. In the 2000 network, the United States and Japan had a very strong influence in all aspects, including connectivity and strength. However, in 2017, China's power index rose to number one among 62 countries in the network. Furthermore, this study presented strategic implications of the Korean electrical and electronic industries to respond to the reorganization of GVSs based on the analysis results.

Analysis of Neural Network Approaches for Nonlinear Modeling of Switched Reluctance Motor Drive

  • Saravanan, P;Balaji, M;Balaji, Nagaraj K;Arumugam, R
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1548-1555
    • /
    • 2017
  • This paper attempts to employ and investigate neural based approaches as interpolation tools for modeling of Switched Reluctance Motor (SRM) drive. Precise modeling of SRM is essential to analyse the performance of control strategies for variable speed drive application. In this work the suitability of Generalized Regression Neural Network (GRNN) and Extreme Learning Machine (ELM) in addition to conventional neural network are explored for improving the modeling accuracy of SRM. The neural structures are trained with the data obtained by modeling of SRM using Finite Element Analysis (FEA) and the trained neural network is incorporated in the model of SRM drive. The results signify the modeling accuracy with GRNN model. The closed loop drive simulation is performed in MATLAB/Simulink environment and the closeness of the results in comparison with the experimental prototype validates the modeling approach.

A Transient stability Analysis Algorithm Using decoupled Network Solution

  • Park, Young-Moon;Park, Jong-Bae
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.135-139
    • /
    • 1988
  • This paper presents a new algorithm using power flow solution which is given by the polar form Newton-Raphson method in a transient stability analysis. The computation time to solve network equations can be much saved by a decoupled power flow method. In addition, the time is much saved in performing a approximate stability analysis by linearizing the differential equations and using a voltage and angle sensitivity matrix given in network equations.

  • PDF

IEMI 복사에 의한 네트워크 통신 장비의 취약성 분석 (Vulnerability Analysis of Network Communication Device by Intentional Electromagnetic Interference Radiation)

  • 서창수;허창수;이성우;진인영
    • 한국전기전자재료학회논문지
    • /
    • 제31권1호
    • /
    • pp.44-49
    • /
    • 2018
  • This study analyzed the Vulnerability of Network Communication devices when IEMI is coupled with the Network System. An Ultra Wide Band Generator (180 kV, 700 MHz) was used as the IEMI source. The EUTs are the Switch Hub and Workstation, which are used to configure the network system. The network system was monitored through the LAN system configuration, to confirm a malfunction of the network device. The results of the experiment indicate that a malfunction of the network occurs as the electric field increases. The data loss rate increases proportionally with increasing radiating time. In the case of the Switch Hub, the threshold electric field value was 10 kV/m for all conditions used in this experiment. The threshold point causing malfunction was influenced only by the electric field value. The correlation between the threshold point and pulse repetition rate was not found. However, in case of the Workstation, it was found that as the pulse repetition rate increases, the equipment responds weakly and the threshold value decreases. To verify the electrical coupling of the EUT by IEMI, current sensors were used to measure the PCB line inside the EUT and network line coupling current. As a result of the measurement, it can be inferred that when the coupling current due to IEMI exceeds the threshold value, it flows through the internal equipment line, causing a malfunction and subsequent failure. The results of this study can be applied to basic data for equipment protection, and effect analysis of intentional electromagnetic interference.

과도현상 해석을 위한 시간 영역에서의 등가축약법 :프로니 해석기법을 이용한 등가 구동점 임피던스 모델의 구성 (Time domain Reduction Method for Electromagnetic Transients Study: Equivalent Driving-Point Impedance Model using Prony Analysis)

  • 홍준희;박종근
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.687-690
    • /
    • 1994
  • This paper presents a method of obtaining transmission network equivalents from the network's response to the pulse excitation signal. Proposed method is base on Prony signal analysis and jtransfer function identification technique. As a result Thevenin-type of discrete-time filter model can be generated. It can reproduce the driving point impedance characteristic of the network.

  • PDF

Universal SSR Small Signal Stability Analysis Program of Power Systems and its Applications to IEEE Benchmark Systems

  • Kim, Dong-Joon;Nam, Hae-Kon;Moon, Young-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.139-147
    • /
    • 2003
  • The paper presents a novel approach of constructing the state matrix of the multi-machine power system for SSR (subsynchronous resonance) analysis using the linearized equations of individual devices including electrical transmission network dynamics. The machine models in the local d-q reference frame are integrated with the network models in the common R-I reference frame by simply transforming their output equations into the R-I frame where the transformed output is used as the input to the network dynamics or vice versa. The salient feature of the formulation is that it allows for modular construction of various component models without rearranging the overall state space formulation. This universal SSR small signal stability program provides a flexible tool for systematic analyses of SSR small-signal stability impacts of both conventional devices such as generation systems and novel devices such as power electronic apparatus and their controllers. The paper also presents its application results to IEEE benchmark models.

Improved Characteristic Analysis of a 5-phase Hybrid Stepping Motor Using the Neural Network and Numerical Method

  • Lim, Ki-Chae;Hong, Jung-Pyo;Kim, Gyu-Tak;Im, Tae-Bin
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권2호
    • /
    • pp.15-21
    • /
    • 2001
  • This paper presents an improved characteristic analysis methodology for a 5-phase hybrid stepping motor. The basic approach is based on the use of equivalent magnetic circuit taking into account the localized saturation throughout the hybrid stepping motor. The finite element method(FEM) is used to generate the magnetic circuit parameters for the complex stator and rotor teeth and airgap considering the saturation effects in tooth and poles. In addition, the neural network is used to map a change of parameters and predicts their approximation. Therefore, the proposed method efficiently improves the accuracy of analysis by using the parameter characterizing localized saturation effects and reduces the computational time by using the neural network. An improved circuit model of 5-phase hybrid stepping motor is presented and its application is provided to demonstrate the effectiveness of the proposed method.

옥내 전력선망 분석을 위한 전력선 모델링과 사례 연구 (Power Line Modelling and Case Study for Indoor Power Line Network Analysis)

  • 김원호;황보훈;나완수;박일한;김병성;김창섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2324-2326
    • /
    • 2005
  • For the analysis of domestic Indoor power line network, we defined parameters of transmission line and simulated it. We conducted the case study which shows the general characteristics of KSC3302 power line. We will develop software for indoor power line network analysis.

  • PDF