• 제목/요약/키워드: Electrical insulator

검색결과 1,344건 처리시간 0.034초

에폭시 몰드형 BCT의 절연열화 특성 (Characteristics of Insulation Degradation in Epoxy Mold Type BCT)

  • 송재주;이정철;임성훈;고석철;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.902-908
    • /
    • 2005
  • Various stresses (such as electrical stress, mechanical stress, environmental and electrochemical stress, and defects of structure) result in insulation degradation of epoxy mold type insulators. Since the insulation degradation of BCT(Bushing Current Transformer) and bushing proceeds during fabrication process or operation time due to these causes, various methods to reduce the degradation in their insulation ability have been suggested. In this paper, we investigated surface temperature increment of these insulators due to PD(partial discharge). After the voltage applied into the insulator to generate the artificial PD, the surface temperature of the insulator was measured with non-contact thermometer using infrared rays. It was confirmed through the analysis based on PD experiments that the procession in the insulation degradation of the insulator could be estimated through the measurement of the surface temperature in the insulator.

UV 센서 어레이를 이용한 폴리머 애자의 코로나 방전 신호분석 연구 (A Study on the Signal Analysis of Corona Discharge on the Polymer Insulator using UV Sensor Array)

  • 최명일;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.16-20
    • /
    • 2014
  • To prevent any accident in electric power utilities, many researches for inspection and diagnosis deteriorations occurring by corona discharges have been continuously studying. Inspection and diagnosis of electric power utility is very important to prevent an accident. This paper studies a measurement of ultra-violet(UV) ray of corona discharges on polymer insulators using an UV sensor array with an optic lens. The detection of an UV signal begins at 60kV, which is about 37.5% of the breakdown voltage of the polymer insulator and the stronger the high voltage increased to the polymer insulator was. It can be determined that the polymer insulator mounted on a live part must be examined when the discharge risk exceeds approximately 40%. In conclusion, the status of power utilities can be checked using an UV sensor.

구조 및 두께 변화에 따른 후막 전계 발광소자에 관한 연구 (A Study on Powder Electroluminescent Device through Structure and Thickness Variation)

  • 오주열;정병선;이종찬;박대희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1998년도 학술발표회논문집
    • /
    • pp.9-11
    • /
    • 1998
  • A phenomenon of electroluminescent radiate as electric field applied in the phosphor, in this paper, we produced the Powder Electroluminescent Device(PELD) which was changing the structure and the thickness of phosphor and insulator for realization of the PELD with high brightness. We made PELD with structure that is WK-1(ITO film/Phosphor/Insulator/Electrode), WK-2(ITO film/Phosphor/Insulator/Electro de), WK-3(ITO film/Phosphor/Insulator/Electrode), WK-4(ITO film/Phosphor+Insulator/ Electrode). The property of the produced PELD are analyzed by measuring the spectrum which electrical and optical property, the brightness and the transferred charge density. In this result, the structure of WK-4 have good luminescence property than others, it's effective thickness is 60${\mu}{\textrm}{m}$. At 100V 400Hz, High brightness of 2700cd/m2 was performed.

  • PDF

폴리머 LP애자의 설계해석과 전기적 성능 시험 (The Design Analysis and Electrical Performance Test of Polymer LP Insulator)

  • 이운용;조한구;박상호;송홍준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2000
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators for transmission and distribution line have significant advantages over porcelain and glass insulators, especially for ultra-high voltage(UHV) transmission lines. Their advantages are light weight, vandalism resistance and hydrophobicity. In this paper, polymer line post insulator has been designed and investigated electric field distribution by FEM. Designed LP insulators have been tested as insulator performance test, such as power frequency voltage test, lightning impulse voltage test, artificial pollution test and flexural load test.

  • PDF

폴리머 절연물 소재의 전기적 밀 복합열화 특성평가 기술 (Evaluation Technology of Electrical and reliableility Characteristics for Outdoor Polymer Insulator Materials)

  • 안명상;박효열;나문경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1343-1344
    • /
    • 2006
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF

송전용 폴리머 애자의 산불영향 신뢰성 평가(I) (Reliability Assessment of Forest Fire on Transmission Lines Polymer Insulator(I))

  • 최인혁;이동일;전영준;이철호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.425-428
    • /
    • 2004
  • 65% of the Korean peninsula is composed of mountainous area, 97% of which is composed of forest. Therefore, there is high possibility of mountain fire because a lot of potential inflammables such as fallen leaves are stacked on the ground. Moreover, most of the overhead transmission lines in Korea are operated on the mountain. However, there has been very little study for the effect of mountain fire on polymeric insulator for transmission line, though the study is significantly required Therefore, in this study the authors observed the deformation of the housing of the insulator under fire with respect to the ignition time, using artificial ignition testing equipment, and investigated electrical and mechanical characteristics of the insulator by dry withstand voltage test, impulse flashover test and tensile load test.

  • PDF

애자표면의 오손물 누적에 관한 메커니즘 연구 (A Study on Mechanism about Contaminant Accumulation of Insulator Surface)

  • 박재준
    • 정보학연구
    • /
    • 제8권2호
    • /
    • pp.85-91
    • /
    • 2005
  • We studied a pollution mechanism for simulation of contamination environment in industrial concentrated area of around a metropolitan that made to circulated flow in the chamber. In case of the virgin both side of EPDM or Silicon insulator, we confirmed that the pollution to much more than service insulator in the field. Also contamination of initial state of the virgin didn't falling in spite of physical outside factor easily. This study confirmed to that the silicon was too much accumulated pollution contrast to EPDM insulator from scatter(spray) point to regular interval position use the Kaolin contaminant in the chamber. There are effected to the hydrophobicity of polymer insulator due to the pollution. In ceramic insulator, we get to know that pollution is much more at the Post insulator with vertical than with horizontal setup insulator.

  • PDF

게이트 절연막에 의한 다이아몬드 MIS (Metal-Insulator-Semiconductor) 계면의 전기적 특성 개선과 전계효과 트랜지스터에의 응용 (Improvement of Electrical Properties of Diamond MIS (Metal-Insulator- Semiconductor) Interface by Gate Insulator and Application to Metal-Insulator- Semiconductor Field Effect Transistors)

  • 윤영
    • 한국전자파학회논문지
    • /
    • 제14권6호
    • /
    • pp.648-654
    • /
    • 2003
  • 본 논문에서는 비 산화물인 불소화합물 게이트절면막을 이용하여 박막반도체 다이아몬드 MS계면(Metal-Insulator-Semiconductor Interface)의 전기적 안정화를 실현하였다. 특히 산소 게터링 효과(Oxygen-Gettering Effect)에 의한 표면준위 억제를 통해, 박막반도체 다이아몬드 MIS계면에 있어서 최적의 전기적 특성을 부여하는 BiF2 게이트절연막을 개발하였다. 본 논문의 결과에 의하면, BaF$_2$ 게이트 절연막을 이용하여 제작한 A1/BaF2/diamond MIS 다이오드와 MISFET(Metal-Insulator-Semiconductor Field Effect Transistor)로부터 저농도의 ~10101/$\textrm{cm}^2$ eV의 표면준위밀도가 관측되었고, 그리고 이제까지 발표된 다이아몬드 박막반도_체 FET중 최고치인 400 $\textrm{cm}^2$/Vs의 유효이동도가 관찰되었다.

Characterization of a Solution-processed YHfZnO Gate Insulator for Thin-Film Transistors

  • Kim, Si-Joon;Kim, Dong-Lim;Kim, Doo-Na;Kim, Hyun-Jae
    • Journal of Information Display
    • /
    • 제11권4호
    • /
    • pp.165-168
    • /
    • 2010
  • A solution-processed multicomponent oxide, yttrium hafnium zinc oxide (YHZO), was synthesized and deposited as a gate insulator. The YHZO film annealed at $600^{\circ}C$ contained an amorphous phase based on the results of thermogravimetry, differential thermal analysis, and X-ray diffraction. The electrical characteristics of the YHZO film were analyzed by measuring the leakage current. The high dielectric constant (16.4) and high breakdown voltage (71.6 V) of the YHZO films resulted from the characteristics of $HfO_2$ and $Y_2O_3$, respectively. To examine if YHZO can be applied to thin-film transistors (TFTs), indium gallium zinc oxide TFTs with a YHZO gate insulator were also fabricated. The desirable characteristics of the YHZO films when used as a gate insulator show that the limitations of the general binary-oxide-based materials and of the conventional vacuum processes can be overcome.

고속철도용 유리애자의 진동 및 파손가능성 분석 (Analysis of Fault Possibility and Vibration of Glass Insulator on High-speed Railway)

  • 김영석;송길목;정진수;김선구;전용주;류영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2044-2045
    • /
    • 2008
  • This paper was studied fault possibility of glass insulator through the proper vibration and field vibration comparison. The proper vibration of 1 cell glass insulator have many frequency band and high amplitude showed in high frequency than low frequency. The field signal amplitude of viaduct and open route were biggest moment pantograph of high-speed rail. From the FFT analysis of viaduct and open route, in the case of positive direction, the strut tube insulator effect by vertical vibration was big, the frequency was 82.5Hz and 105Hz, respectively. However, in the case of negative direction, the vibration did not cause big effect. In comparison with the proper vibration of glass insulator, the resonance was not observed.

  • PDF