• Title/Summary/Keyword: Electrical heater

Search Result 358, Processing Time 0.023 seconds

Fault Prediction Based on Unbalanced Current Detection of Three Phase Heater and Selection of the Protective Device (3상 히터의 불평형전류 검출에 의한 결함예측 및 보호장치의 선정)

  • Lee, Mun Hyung;Jung, Jae Hee
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.28-33
    • /
    • 2015
  • Three phase heaters in 7 buildings of 2 sites were examined for precise diagnosis. The sample size was 626. Precise examinations of current and the heater wiring status revealed contact failures and arcs in equipments that had CUF larger than 10%. Contact failures and arcs may cause electrical fire. Therefore, the correlation between the CUF and the imperfections in heater equipment and its wiring was analyzed for three phase heaters. In addition, the protection devices used for detection of heater imperfections were found to be unsuitable for the purpose. Current status of the protection devices was analyzed, and suggestions for improvements were made for new standards of the protection device selection.

Development of Measurement and Performance Testing System for Heat Pump water Heater (히트펌프 온수기 개발을 위한 계측 및 성능평가시스템 구축)

  • Kwon, Seong-Chul;Yang, Seung-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2310-2312
    • /
    • 2004
  • In Korea Electric Power Corporation (or KEPCO), several Demand-Side Management (or DSM) program have been carried out to effectively meet electric power demand at least costs by modifying customers electricity use patterns. As one of them, KEPCO applies low-priced night thermal-storage power service for heat appliances to facilitate efficient use of power facilities by shifting relatively high daytime demands to night hours to build loads during the off-peak periods. In the market of heat-storage type water-heater, electric water-heater has been mostly used, but it has low energy efficiency and needs high capacity electric equipments. So in order to replace these electric water heaters, 15 HP air-source heat pump water heater is developed in Korea Electric Research Institute (or KEPRI). This paper shows that measurement system for performance testing of heat pump water heater is established and heating capacity and performance is analyzed and measured for out-door environmental change.

  • PDF

Development of Components in Micro Solid Propellant Thruster. (마이크로 고체 추진제 추력기의 요소 개발)

  • 이종광;이대훈;권세진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.147-150
    • /
    • 2003
  • The purpose of this research was to develope components of micro solid propellant thruster. Micro solid propellant thruster had four basic components: combustion chamber, nozzle, solid propellant and micro heater for ignition. A performance of micro heater and characteristic of solid propellant was investigated. Micro heater was fabricated by conventional MEMS process and Platinum layer was used for heating element. Effect of geometry parameters on micro heater was tested. The temperature responses of heater with respect to each parameters was compared for a given electrical power. The characteristic of solid propellant(HTPB/AP) was investigated to obtain burning velocity in small chamber. Additionally, a capacity of filling propellant with high viscosity in small chamber was checked to guarantee for the micro fabrication.

  • PDF

Improvement of Production Process based on Performance Evaluation System of Unified Heater (통합히터 성능평가장치를 통한 생산 공정 개선)

  • Han, Woo-Hyun;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.114-118
    • /
    • 2014
  • This paper presents improvement of the production process of a unified fuel heater with the help of the performance evaluation system. In order to enhance a starting capability of diesel-engine car, the unified fuel heater is proposed, which consists of main body, upper plate, stopper, lower plate, PTC, screw, bimetal and terminals. In the proposed heater, the sensor is combined with heater body not only to maximize the performance of car but also to reduce the production cost. The performance test chamber is proposed to evaluate the performance of heater. Especially, an effective manufacturing progress for assembling the heater elements can cut down expenses.

Application of an Infrared Drying to Drying Process for Red Pepper (고추의 건조(乾燥) 공정(工程)에서 적외선(赤外線) 건조법(乾燥法)의 활용(活用)에 관한 연구(硏究))

  • Koh, H.K.;Cho, Y.J.;Kang, S.W.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.3
    • /
    • pp.230-243
    • /
    • 1990
  • This study was conducted to investigate the possibility of application of an infrared drying to drying process for red pepper. The performance of seramic heaters and the variation of temperature and moisture content of red pepper were analyzed during an infrared drying of red peppers. Also, the quality of dried red pepper was analyzed. The following results were obtained from this study. 1. The surface temperature of infrared heaters and the rising time required for steady state were mainly affected by electrical power consumed. 2. The heat energy required for heating red pepper was proposed to be calculated by the equation in terms of enthalpy of air and net heat flux by infrared heater in a drying chamber. The statistical model for net heat flux was developed. 3. The performance of the infrared heater used for heating red pepper was much affected by the distance of radiation, and the difference of temperatures appeared between the radiated surface and the inside of red pepper. 4. Electrical capacity of the infrared heater had a significant effect on the heating of red pepper. However, the effect of shape of heater on heating was not significant. 5. The variation of temperature of red pepper largely appeared in the range of 30 to 60% (db) in moisture content. The temperature of red pepper was almost constant at low moisture content. 6. The temperature of red pepper and heating time had significant effects on the quality for radiant heating. 7. When the electrical capacity of infrared heater and the distance of radiation are carefully designed in a dryer with the insulated drying chamber, infrared drying might be very effective in red pepper drying.

  • PDF

Carbon Nanotube Heater Generating High Heat Flux

  • Kang, Yong-Pil;Lee, Hyun-Chang;Kim, Duck-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.530-530
    • /
    • 2012
  • Many practical applications of carbon nanotubes(CNTs) have been proposed and there have been attempts to utilize CNT films as transparent electrodes for solar cells and displays. Our group has considered the use of the CNT film as a thin film heater (TFH) and proposed it for the first time and reported the thermal behavior of the TFH made of single walled CNTs. However, due to the relatively high electrical resistance of the CNT film, using the TFH in application areas requiring high heat flux has been a difficult problem. To overcome this obstacle, we adopted a 'branch electrodes' concept to increase the film conductance dramatically. If two branch electrodes are inserted into a TFH whose original electrical resistance is R, the total resistance will be reduced to R/9. Because of the increased aspect ratio, the resistance of each segmented TFH will be reduced to R/3. Furthermore, since they are connected in parallel, the total resistance reduces to R/9. This could be extended to n branch electrodes, and the total resistance of the film will be reduced to R/(n+1)2, if the resistance of electrodes are negligibly small. We fabricated the heaters with different number of branch electrodes. The number of branch electrodes of the fabricated heaters are 0, 2, 4, 8 and their electrical resistance are 101.4, 39.5, 20.0, $15.4{\Omega}$, respectively. We applied 20V to each heater and monitored the temperature variations. We could achieve high heating temperature even with low voltage supply. This technique could be applied to relevant industrial applications which need high power film heater.

  • PDF

A Study on the Characteristics of μc-Si:H Films Prepared by Multistep Deposition Method using SiH4/H2 Gas Mixture (SiH4/H2 혼합기체를 Multistep 방식으로 증착한 수소화된 실리콘 박막의 특성 연구)

  • Kim, Taehwan;Kim, Dong-Hyun;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.250-256
    • /
    • 2014
  • In this study, we deposited and investigated ${\mu}c$-Si:H thin films prepared by Plasma Enhanced Chemical Vapor Deposition(PECVD) system. To deposition silicon thin films, we controlled $SiH_4$ gas concentration, RF input power, and heater temperature. According to the experiments, the more $SiH_4$ gas concentration increased, deposition rate also increased but crystalline property decreased at the same conditions. In the RF input power case, deposition rate and crystalline property increased together when the input power increased from 100[W] to 300[W]. If RF input power was 300[W], deposition rate has reached saturation point. In the heater temperature, deposition rate increased when heater temperature increased. Crystalline property maintained a certain level until heater temperature was $250[^{\circ}C]$. And then it was a suddenly increased. Multistep method has been proposed to improve the quality of ${\mu}c$-Si:H thin film. $SiH_4$ gas was injected with a time interval. According to the experiments, crystallite ratio improve about 20~60[%] and photo conductivity increased up to six times.

A Study on Improvement of Heater Rod Adhesion in Semiconductor Equipment (반도체 장비 히터로드 유착 개선에 관한 연구)

  • Wang, Hyun-Chul;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.1
    • /
    • pp.67-72
    • /
    • 2020
  • This study analyzes the method of adhesion and improvement between heat.er and RF filter in PE-CVD equipment through TRIZ method and proposes a solution. TRIZ Solution such as function analysis, 9-window matrix, ASIT, and Root cause analysis were used. The contact temperature between the heater and the RF filter was 20% and the surface temperature was lowered to 5.7℃, suggesting an improvement method for the thermal expansion of the PE-CVD equipment hot zone.

RF Loss Minimization Method Using High Impedance Filter for Research (High Impedance Filter를 이용한 RF Loss 최소화 방법에 대한 연구)

  • Wang, Hyun-Chul;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.1
    • /
    • pp.55-60
    • /
    • 2020
  • This study designed High impedance filter to reduce RF loss to heater heating wire and increase RF current flowing to heater ground wire. Effects such as D / R improvement and process reproducibility could be seen. In addition, RF parameter distribution optimization was possible by understanding the RF path of PE-CVD equipment using Plasma and designing filter.