• 제목/요약/키워드: Electrical breakdown characteristics

검색결과 1,008건 처리시간 0.026초

전자선 조사된 에폭시 수지의 절연파괴 특성 (The Characteristics of Dielectric Breakdown for Epoxy Resin irradiated Electron Beam)

  • 홍능표;조돈찬;박흥규;소병문;김왕곤;홍진웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.430-432
    • /
    • 1995
  • In this paper, the electron beam with 1[Mrad], 2[Mrad], 4[Mrad], 8[Mrad] and 24[Mrad] is irradiated for specimen experiments on physical properties which is investigated by FTIR, and dielectric breakdown among the electrical characteristics of specimen are carried out. For the dielectric breakdown experiment, external 60 [Hz] AC voltage is applied to specimen with the rising voltage of 3[kV/cm] until dielectric breakdown occured. We made a breakdown experiment under the temperature condition of 50[$^{\circ}C$], 100[$^{\circ}C$], 150[$^{\circ}C$] in the silicone oils of dynamic viscosity of 100[cSt].

  • PDF

XLPE/SXLPE 블랜드의 수트리 성장 및 절연파괴 특성 (Water Tree Growing and Electrical breakdown Characteristics of XLPE/XLPE blends)

  • 고정우;서광석
    • 한국전기전자재료학회논문지
    • /
    • 제13권5호
    • /
    • pp.420-425
    • /
    • 2000
  • Crosslinked polyethlyene/silane crosslinked polyethylene(XLPE/SXLPE) blends were prepared by a twin screw extruder and their water tree growing electrical breakdown and crossinking characteristics were investigated. The water tree characteristics of XLPE were improved by the addition of SXLPE when samples were crosslinked only by the thermorolysis of DCP (dicumyl peroxide). However steam curing process was not good for water tree characteristics. It was also found that the rate of water tree growing of XLPE/SXLPE blend increased when the content of SXLPE was 50%. AC breadown strength slightly increaed by the addition of SXLPE to XLPE when samples were crosslinked only by the thermorolysis of DCP. It was also found that the degree of crosslinking of XLPE/SXLPE blends were higher than that of XLPE in the case of the content without steam crosslinking process.

  • PDF

불평등전계중에서 진동성 임펄스전압에 대한 $SF_6$가스의 절연특성 (Dielectric Characteristics of $SF_6$ gas Stressed by the Oscillating Impulse Voltage in the Non-uniform Electric Fields)

  • 이복희;길경석;황교정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.284-286
    • /
    • 1994
  • This paper describes the dielectric characteristics of $SF_6$ gas in non-uniform electric filed under lightning under lightning impulse and oscillating impulse voltages. The breakdown voltage-time characteristics and the breakdown voltage-pressure characteristics are measured over a pressure range extending from 0.1 to 0.5 [MPa] fur the coaxial electrode with a needle protrusion. The curvature radius of needle protrusion is 0.3[mm]. Also, the growth of the predischarge is simultaneously observed. As a result the polarity effect is pronounced, and the breakdowns voltage under the oscillating impulse voltage are higher than those under the lightning impulse voltage. It is found that the breakdown mechanism md predischarge phenomena ate closely related with the polarity and waveforms of the testing voltage.

  • PDF

$(Sr{\cdot}Pb)TiO_3$계 세라믹의 전기전도 및 절연파괴 특성에 관한 연구 (A Study on the Electrical Conduction and D.C. Breakdown Properties of $(Sr{\cdot}Pb)TiO_3$ Series Ceramic)

  • 정일형;최운식;김충혁;이준웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.321-324
    • /
    • 1991
  • In this study, $(Sr{\cdot}Pb)TiO_3$ series ceramics which is used in high voltage were fabricated by the mixed oxide method, and the electrical conduction mechanism and D.C. breakdown voltage characteristics of the specimens in accordance with the contents of $Bi_2O_3{\cdot}3TiO_2$ were investigated. As a result, the leakage current was increased with the contents of $Bi_2O_3{\cdot}3TiO_2$ and the measuring temperature. At room temperature, the leakeage current was showed a tendency of saturating when D.C. electrical field of $l5{\sim}30$[kV/cm] was applied to the specimen. As a result of breakdown voltage characteristics. breakdown strength was decreased when the contents of $Bi_2O_3{\cdot}3TiO_2$ were increased. On the other hand, in the temperature region below $60[^{\circ}C]$, the electronic breakdown was occured, and in the temperature region from 60 to $200[^{\circ}C]$, the thermal breakdown was occured by the Joule heat and the dissipation factor.

  • PDF

고압전동기 고정자 권선의 절연열화 평가 (Assessment of Insulation Deterioration in Stator Windings of High Voltage Motor)

  • 김희동;공태식
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.711-716
    • /
    • 2012
  • To assess the insulation deterioration of stator windings, diagnostic and AC breakdown tests were performed on the eleven high voltage (HV) motors rated at 6kV. After completing the diagnostic tests, the AC overvoltage test was performed by gradually increasing the voltage applied to the stator windings until electrical insulation failure occurred, to obtain the breakdown voltage. Stator winding of motors 1, 3, and 8 failed at above rated voltage at 14 kV, 13.8kV, and 16.4kV, respectively. The breakdown voltage of three motors was higher than expected for good quality windings in 6kV motors. Based on deterioration evaluation criteria, the stator winding insulation of eleven HV motors are confirmed to be in good condition. The turning point of the current, $P_{i2}$, in the AC current vs. voltage characteristics occurred between 5kV and 6kV, and the breakdown voltage was low between 13.8kV and 16.4kV. There was a strong correlation between the breakdown voltage and various electrical characteristics in diagnostic tests including Pi2.

초미소간격(超微小間隔)과 극단(極端)펄스방전(放電)을 이용(利用)한 미연소탄소립자(未燃燒炭素粒子) 소각제거기술(燒却除去技術) 개발기초연구(開發基礎硏究)(I) (초미소간격(超微小間隔)의 방전현상(放電現象)) (A Basic Study on a New Type Particulate Emission Control Means of a Power Station Using a Micro-Gap and a Pulse Discharge (Micro-Airgap Discharge Phenomena))

  • 문재덕;신수연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.605-608
    • /
    • 1993
  • Breakdown characteristics of a small rod-to-rod microairgap has been studied for obtain an optimum breakdown voltage and an airgap spacing to be used as an emission control means by the electrical arc-burning unburnt carbon particulates exhausted from a power station burner. It is found that the breakdown voltage at the rod-to-rod airgap spacing in the rang of $1{\sim}100{\mu}m$ decreased with decrease in the rod-to-rod airgap spacing. And there were no minimum breakdown voltage on a $V_b$-Pd characteristics which is known as the minimum voltage in Paschen's law in air atmosphere. Breakdown voltages of the airgap at the constant airgap spacing were $V_{b-dc}>V_{b-ac}>V_{b-pulse}$, and it was lowest for the pulse voltage applied. As a result, it is found that a pulse power was one of effective power compared with dc or ac to be used as such an unburnt carbon particulate emission control means and the airgap spacing became to several tens ${\mu}m$, then the breakdown voltages were down to several handreds voltages.

  • PDF

$SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성 (V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages)

  • 이복희;이경옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF

얕은 트렌치와 전계 제한 확산 링을 이용한 접합 마감 설계의 1200 V급 소자에 적용 (The Junction Termination Design Employing Shallow Trench and Field Limiting Ring for 1200 V-Class Devices)

  • 하민우;오재근;최연익;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권6호
    • /
    • pp.300-304
    • /
    • 2004
  • We have proposed the junction termination design employing shallow trench filled with silicon dioxide and field limiting ring (FLR). We have designed trenches between P+ FLRs to decrease the junction termination radius without sacrificing the breakdown voltage characteristics. We have successfully fabricated and measured improved breakdown voltage characteristics of the Proposed device for 1200 V-class applications. The junction termination radius of the proposed device has decreased by 15%-21% compared with that of the conventional FLR at the identical breakdown voltage. The junction termination area of the proposed device has decreased by 37.5% compared with that of the conventional FLR. The breakdown voltage of the proposed device employing 7 trenches was 1156 V, which was 80% of the ideal parallel-plane .junction breakdown voltage.

설계 및 공정 변수에 따른 600 V급 IGBT의 전기적 특성 분석 (Analysis of The Electrical Characteristics of Power IGBT According to Design and Process Parameter)

  • 강이구
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.263-267
    • /
    • 2016
  • In this paper, we analyzed the electrical characteristics of NPT planar and trench gate IGBT after designing these devices according to design and process parameter. To begin with, we have designed NPT planar gate IGBT and carried out simulation with T-CAD. Therefore, we extracted design and process parameter and obtained optimal electrical characteristics. The breakdown voltage was 724 V and The on state voltage drop was 1.746 V. The next was carried out optimal design of trench gate power IGBT. We did this research by same drift thickness and resistivity of planar gate power IGBT. As a result of experiment, we obtain 720 V breakdown voltage, 1.32 V on state voltage drop and 4.077 V threshold voltage. These results were improved performance and fabrication of trench gate power IGBT and planar gate Power IGBT.

Effects of Temperature and Pressure on the Breakdown Characteristics of Liquid Nitrogen

  • Baek, Seung-Myeong;Joung, Jong-Man;Kim, Sang-Hyun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권5호
    • /
    • pp.171-176
    • /
    • 2003
  • For practical electrical insulation design of high temperature superconducting (HTS) power apparatuses, knowledge of the dielectric behavior of both liquid nitrogen (L$N_2$) and subcooled liquid nitrogen (SL$N_2$) are essential. To achieve SL$N_2$ at atmospheric pressure, cryostat was designed and constructed. By pumping up the L$N_2$ in the outer dewar, the temperature of L$N_2$ in the inner dewar at atmospheric pressure can be controlled. The breakdown characteristics of L$N_2$ in quasi-uniform and non-uniform electrical fields for temperatures ranging from 77 K to 65 K at atmospheric pressure and pressure ranging from 0.1 to 0.5 MPa were investigated experimentally. The experimental data suggested that the breakdown voltage (BDV) of L$N_2$ is both highly temperature and pressure dependent. We also carried out statistical analysis of the experimental results using the Weibull distribution. The Weibull shape parameter m for the sphere-to-plane electrodes in SL$N_2$ was estimated to be 11 to 18.