• Title/Summary/Keyword: Electrical accident

Search Result 519, Processing Time 0.035 seconds

A Study on the Reduction of Onboard Transformer Inrush Current of Electric Railway (전기철도 차량 내 변압기의 여자돌입전류 저감에 관한 연구)

  • Huh, Jae-Sun;Kang, Byoung-Wook;Shin, Hee-Sang;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2125-2130
    • /
    • 2010
  • The neutral section on electric railway system is significant sector in order to prevent short circuit of two electric powers. However, while electric trains pass the neutral section, those speed is decreased and the accident of AC electric traction system and the electric train would be occurred. So the countermeasures are urgently needed. The automatic power switching technology system that is current being research and development is system to improve these problems. Because main object of this system is power change using static switch in the neutral section, it's expected to cause a variety of transients. Especially, onboard transformer inrush current for electric railway train can be occurred more than rated current according to switching time. Therefore, the analysis and improvement are needed to ensure the stability of this system. In this paper, we analyze the operating characteristics of the automatic power switching technology system. Especially, it reviews inrush current according to the closing phase angle. And we propose control plan of inrush current considering the case that voltage is maintained due to counter electromotive force and regenerative braking operation of electric railway train. Finally, the proposed control scheme was reviewed using the transient analysis program.

The Influence of Energy Density upon Detection Time of Information Signal in AF Track Circuit (AF궤도회로에서 에너지 밀도가 정보신호 검출시간에 미치는 영향)

  • Kim, Min-Seok;Hwang, In-Kwang;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1146-1151
    • /
    • 2011
  • There are two methods for train control in information transmission by using track circuit system and installing wayside transmitter. Information signal is transmitted to the on-board antenna by using rails. Continuous information about train intervals, speed and route is received by on-board antenna in AF track circuit system. The information signal is included with carrier wave and received by magnetic coupling in the on-board antenna. Therefore, it is important to define standard current level in the AF track circuit system. When current flowed to rails is low, magnetic sensors are not operated by decreasing magnetic field intensity. Hence, SNR is decreased because electric field intensity is decreased. When the SNR is decreased, there is the serious influence of noise upon demodulation. So, the frequency of information signal is not extracted in frequency response. Thus, it is possible to happen to train accident and delay as the information signal is not analyzed in the on-board antenna. In this paper, standard energy density is calculated by using Parseval's theory in UM71c track circuit. Hence, detection time of information signal is presented.

Study on Reliability of Water Absorption Diagnosis through Precise Water Absorption Test

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.772-777
    • /
    • 2012
  • Accidents caused by water absorption in water-cooled generator stator windings often occur all over the world. The absorption into the insulator of the coolant, which is used to cool down the heat generated by stator windings during operation, leads to the deterioration of dielectric strength, and insulation breakdown. An insulation breakdown may cause not only an enormous economic loss but also a very serious grid accident that would compromise stable supply of electric power. More than 50 % of domestic generators have been in operation for more than 15 years, and water absorption tests performed on 50 water-cooled generator stator windings during a five-year planned preventive maintenance period beginning in 2006 identified water absorption problems in 10 of them, all of which required repair. Because the existing water absorption test detects this problem by utilizing stochastic methods after measuring the capacitances at the final positions of insulation breakdown, its accuracy is limited. This study demonstrates that water absorption can be more accurately diagnosed by utilizing method along with a more precise one.

A Study on the emergency and repairing AC/DC combination lamp (AC/DC 겸용 비상 및 복구등에 관한 연구)

  • An, Youn-Ki;Choi, Hong-Kyoo;Choi, June-Young;Lee, Jung-Youl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.19-25
    • /
    • 2009
  • The Study is for improvement of power plant equipment environment. Emergency lamp already installed In transformer substations has weak Illuminance. Because emergency battery is limited and incandescent electric lamps installed has low intensity of illumination and bad efficiency. It is too dark to operate many types of equipment in work Therefore this paper proposes that we use fluorescent lamp instead of incandescent electric lamp and change the old illumination standard for evident standard from the can coup with accident rapidly.

  • PDF

Development of Speaker Recognition System in FES for General Paralysis Patients (전신마비환자용 기능적 전기자극기 화자인식 시스템의 개발)

  • 진달복;이영석;이현희;정호춘;임승관;여운진
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.819-825
    • /
    • 2003
  • The purpose of this study is to develop the speaker recognition system which can select one of operating modes in FES for general paralysis patients. As spiral injury by traffic accident, industrial disaster, or stroke has been increased, the development of FES(Functional Electrical Stimulator) system is urgent to prevent paralysis and atrophy, and to assist the patients walking. For these patients we developed FES system(1). To operate this system one of several operating modes must be selected. As this can not be done by general paralysis patients, an attempt has been tried in this study to select the mode by speaker recognition system. RSC-300 of sensory co. has been chosen as a speaker recognition chip, and PIC16F84 is adapted to interface RSC-300 and FES system.

Realtime e-Actuator Fault Detection using Online Parameter Identification Method (온라인 식별 및 매개변수 추정을 이용한 실시간 e-Actuator 오류 검출)

  • Park, Jun-Gi;Kim, Tae-Ho;Lee, Heung-Sik;Park, Chansik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.376-382
    • /
    • 2014
  • E-Actuator is an essential part of an eVGT, it receives the command from the main ECU and controls the vane. An e-Actuator failure can cause an abrupt change in engine output and it may induce an accident. Therefore, it is required to detect anomalies in the e-Actuator in real time to prevent accidents. In this paper, an e-Actuator fault detection method using on-line parameter identification is proposed. To implement on-line fault detection algorithm, many constraints are considered. The test input and sampling rate are selected considering the constraints. And new recursive system identification algorithm is proposed which reduces the memory and MCU power dramatically. The relationship between the identified parameters and real elements such as gears, spring and motor are derived. The fault detection method using the relationship is proposed. The experiments with the real broken gears show the effectiveness of the proposed algorithm. It is expected that the real time fault detection is possible and it can improve the safety of eVGT system.

The Study of Electromagnetic Force by Three Phase Short-Circuit Test of Cable (케이블 삼상단락 실증시험을 통한 전자력 영향 검토)

  • Hong, Dong-Suk;Kim, Hae-Jun;Park, Sung-Min;Chang, Woo-Suk;Park, Heong-Suk;Jang, Tae-In;Kang, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.395_396
    • /
    • 2009
  • This paper handles with effect of electromagnetic force on the cables by fault current accompanied by accident of underground transmission cable. Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, interaction of electromagnetic force from fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, etc. and close consideration is required for it. This paper describes the effect of electromagnetic force through results of three phase short-circuit test and electromagnetic force analysis using theoretical calculations and electrical evaluation test after three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

  • PDF

Electricity Pricing Policy Alternatives to Control Rapid Electrification in Korea

  • Kim, Changseob;Shin, Jungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.285-299
    • /
    • 2016
  • Although South Korea experienced a rolling blackout in 2011, the possibility of a blackout in South Korea continues to increase due to rapid electrification. This study examines the problems of energy taxation and price distortions as possible reasons for the rapid electrification in South Korea, which is occurring at a faster rate than in Japan, Europe, and other developed countries. Further, we suggest new energy taxation and price systems designed to normalize electricity prices. In order to do so, we consider two possible scenarios: the first imposes a tax on bituminous coal for electricity generation and the second levies a tax to provide compensation for the potential damages from a nuclear accident. Based on these scenarios, we analyze the effects of a new energy system on electricity price and demand. The results show that a new energy system could guarantee the power generation costs and balance the relative prices between energy sources, and could also help prevent rapid electrification. Therefore, the suggested new energy system is expected to be utilized as a basis for energy policy to decrease the speed of electrification, thus preventing a blackout, and to induce the rational consumption of energy in South Korea.

Reliability Improvement of Insulation Diagnosis Using the Hydro-Generator On-Line Partial Discharge Monitoring System (수력발전기 On-line 부분방전 측정 시스템을 이용한 절연상태 진단의 신뢰성 향상)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Lim, Jae-Il;Park, Ji-Kun;Kwak, Won-Ku;Lee, Jae-Heung;Shin, Jae-Pil;Shin, Byoung-Chol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.469-475
    • /
    • 2009
  • Accident dangerousness of domestic hydro power generators which are operated in Korea is on the increase because of use at the long term. On this, the Off-line diagnosis techniques developed to the On-line by continued domestic technical development since 2000. Especially, On-line insulation diagnosis of domestic hydro power generator is possible by localization of partial electric discharge sensor and On-line insulation diagnosis system. This paper shows the diagnosis result that is applied localized Ceramic Coupler and PDMS-HG(Partial Discharge Monitoring System for Hydro Generator) at four Chung-ju hydro Generator used for 25 years. Particularly, the confidence of insulation diagnosis is improved by using high frequency filter and sampling the partial discharge signals which occur in site. For reviewing the confidence of On-Line insulation diagnosis system, we measured the outside noises and partial discharge signals during practical operation by using the partial discharge diagnosis system of the Full A/D process. And we reviewed the confidence of the On-Line insulation diagnosis system by comparing and analyzing these data.

Implementation of Improved Automatic Lighting System using PLC (PLC를 이용한 개선된 자동 조명제어시스템 구현)

  • Kang, Shin-Wook;Joo, Jin-Hwan;Kwon, Hak-Cheol;Lee, Suk-Gyu;Park, Ju-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.99-106
    • /
    • 2010
  • This paper proposes a novel design of enhanced auto light control system using PLC(Power Line Communication) and SMS(Short Message Service) to copy with emergent cases effectively. In the proposed system, the indoor sensing system is designed to send emergent messages to the users or system manager in case of fire or invasion, which may prevent secondary accident. In addition, data transmission using PLC may drastically decreases the number of lines. The experimental results show the effectiveness of the proposed system.