• 제목/요약/키워드: Electrical Shock Accidents

검색결과 58건 처리시간 0.029초

영유아의 사고유형 실태조사와 안전교육 효과 분석 (The Patterns of Accidental Injury in Young Children and Effect of Safety Education on Their Mothers Performance of Preventive Measures)

  • 송인자;한정석
    • 한국보건간호학회지
    • /
    • 제12권1호
    • /
    • pp.55-74
    • /
    • 1998
  • In the past most major accidents resulted in death, but today there is a dramatic increase in the number of people who survive such accidents but who are left with permanent injury. Particularly, children who are inquisitive about their surroundings but immature in their ability to assess danger, are more vulnerable to accidents and their causes as well as to determine attitudes towards prevention. The main objective of the study was to assess the effectiveness of using an accident prevention manual for accident for accident prevention education. The study was a quasi-experimental study using a questionnaire format. The subjects of the study were 393 mothers of children attending six day care centers in Seoul. Data collection was done between May 1 and June 15, 1997. The tools used for the study were a questionnaire developed the researchers and a manual for accident prevention. The collected data were analyzed using SPSS. The results of the study are as follows: 1. Types of accidents included stabbing, bums, falls from heights, choking, falls on slippery surfaces, traffic accidents, drowning, poisoning, and electrical shock in that order of frequency. 2. The main causes of accidents in children were from cosmetics and household medications. 3. The most frequent locations of accidents in the home were the bathroom, kitchen, and stairways in that order. 4. For $90.4\%$ of children safety seats were not used when the ridding in a car. 5. In examining the parents' accident prevention practices, it was found that many parents used only . one electrical outlet for many appliances, tending to overload the electricity lines and that they were not practically concerned bout the flammability of children's pajamas, indicating a less than positive attitude towards fire prevention. 6. The parents had not provided their children with any instruction on accident prevention or on what to do after an accident had occurred. 7. After the use of pamphlet in an accident prevention education program, it was found that there was a statistically significant difference in the degree to which children carried out safety measures (t=14.96, p=.000) and in their safety habits (t=-1.67, p<.1) indicating an effectiveness in this method of education. The results of this study showed that there are many things in a child's environment that can cause accidents and that the possibility of an accident occurring is high. So nurses looking after children should be aware of the need for safety education to prevent accidents in the home and plan to provide appropriate educational material to help parents with this education.

  • PDF

누전차단기 폭로에 따른 동작 특성 및 재료 분석 (The Material Analyses and the Behavior Characteristics according to RCD Discloser)

  • 한운기;김향곤;길형준;이기연;최충석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2019-2021
    • /
    • 2005
  • This paper describes the cut off time and the current characteristics of virgin RCDs and deteriorated ones in the seashore. The RCDs(Residual Current Protective Devices) are used for protecting the human body from electrical shock and for preventing facility accidents. According to the Korean standards, the RCDs are installed in panel boards. When RCDs are installed outside, they must be enclosed inside waterproof cases. In the case that RCOs are employed at temporary power sites and electrical facilities on the road, they are exposed to the external environment. As a result, the RCDs deteriorated in the seashore for 3 months showed high failure rate, while the virgin RCDs all complied with Korean Standard. Considering that the RCDs are used under exposed condition outside, the reliance of RCDs must be ensured by modifying the related regulations and codes and by developing Improved models advanced in their performance.

  • PDF

충전부에 접촉된 인체의 전위특성에 관한 연구 (A Study on the Potential Characteristics of Human-body Contacted the Charging Part)

  • 송길목;최충석;정연하;노영수;곽희로;박중신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1942-1944
    • /
    • 2004
  • In this paper, we studied on the potential characteristics of human-body contacted the charging part. A charging part of electrical facilities and the earth are simulated by the e1ectrode pole and conductive rubber plates respectively. As the results of these follows, when the potential distribution of the human-body contacted the charging part is far from the electrode pole, a lot of currents flow through the human-body. Besides human-body non-contacted the charging part is affected by step voltage. Therefore, we could find out the causes of the electric shock accidents and be expected to the data for minimization of human error occurred the workspace.

  • PDF

지하구내 수.변전설비 안전실태 조사 (A Research on the Safety Condition of Power Utilities Installed on Underground Premises)

  • 정종욱;정진수;이건호;김영석;배석명
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.410-413
    • /
    • 2006
  • This paper describes the safety condition of power utilities installed on underground premises when flooding occurs. As advance preparations, the statistical data were investigated based on the rainfall trend; the flooding damage; the power utilities installation; the electric shock accidents, and domestic md foreign regulations pertaining to the power utilities installation on underground premises were also compared and analyzed. After the preliminaries, the safety condition of underground power utilities was inspected at site and the results were reflected on considering countermeasures. Based on the further studies, the regulations closely related to the underground power utilities installation can be modified.

  • PDF

철도차량기지용 단권변압기의 전압강하에 대한 이론적 고찰 (A Theoretical Study on Voltage Drop of Auto-Transformer for Railway Vehicle Base)

  • 유기성;김재문
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1723-1728
    • /
    • 2018
  • In order to investigate the voltage drop compensation effect of AT for domestic railway vehicle base, the parameters of AT voltage drop of railroad car base are Z3 (Impedance of feeder line), Xn ( Distance from railroad vehicle to AT to SS), and Dn (distance between both ATs of railway vehicle).In addition, when installed in a SSP for a railway vehicle base, there is no AT and feeder line in the railway vehicle base except for the SSP for the main line and the SSP for the railway vehicle base, so that if zero or ignored, the AC single-phase two- It can be confirmed that it becomes a form.

전기분전반용 블록형 부스 바의 구조 설계 연구 (The Structural Design of the Bus-bar block type of electrical switch boards)

  • 권영민;황찬규;김근호;한희
    • 한국산학기술학회논문지
    • /
    • 제17권2호
    • /
    • pp.378-385
    • /
    • 2016
  • 전기 분 배전반의 내부 회로 인 부스 바는 충전부의 노출로 인해 전기 사고의 원인이 되며 이로 인한 감전 사고와 단락 사고가 발생된다. 또한 동물 및 이물질 침투로 인한 전기 화재 사고가 발생되는 원인이 되기도 한다. 또한 확장이 불가능한 구조로 무리하게 연결하여 사용하므로 접촉 저항 증가 발생으로 과열 사고를 유발시키기도 하며, 절단과 절곡 등의 제조 공정상의 어려움을 가지고 있기 때문에 주문생산방식을 택할 수밖에 없는 현실이며, 긴급전기 사고 발생시 복구하는데 지연되는 원인이 되기도 한다. 본 논문에서는 이와 같은 문제점을 개선하기 위해서 분 배전반의 모선을 절단하여 개별 블록으로 절연 난연 케이스와 격벽 구조화로 안전성을 높여 모듈 블록화 하였으며, 확장성과 유연성을 구현하였으며, 쉽게 확장이 가능한 구조이며, 또한 쉽게 분 배전반을 조립할 수 있다는 것이며, 이와 같이 전기적 위험 요소를 제거한 전기 분 배전반의 내부 구조는 블록형 부스 바 구조를 가지고 메인차단기와 분기차단기간의 회로 형성 구현 방식의 분 배전반를 제안하고 공인시험기관의 시험을 통해 그 유용성을 입증 하였다.

태양광발전시스템용 직류 누설전류 센서 개발 (Development of DC Leakage Current Sensor for Solar Power Generation System)

  • 김희선;한송엽;한후석
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.828-833
    • /
    • 2014
  • Grid connected transformerless solar power generation system is frequently used with the benefits of cost and efficiency. However, significant DC leakage current can flow from the DC line into the ground with dielectric breakdown in the transformerless solar power generation system. The leakage current occurred in the DC line causes accidents such as fire and electric shock on human. To resolve this problem, high sensitivity DC leakage current sensor is needed. But recently the studies on safety of DC line are not performed. In this paper, a high sensitivity DC leakage current sensor that can detect DC leakage current in solar power generation system, is proposed. Based on the studies, DC leakage current sensor is fabricated and characteristic tests are carried out. Finally, the accuracy of sensor performance is verified by leakage current experiments in solar power generation system.

전기사고방지를 위한 연구실험실 정기점검/정밀안전진단 표준모델개발 (Development of the Standard Model of a Stated Period Check and Precise Safety Diagnosis in the Research Lab for Prevention to Electrical Accidents)

  • 이동윤
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.858-864
    • /
    • 2011
  • 대학 연구기관 등의 연구실험실에서 감전, 전기화재 등 전기사고를 방지하고 안전을 확보하기위해 수행하는 전기분야 정기점검/정밀안전진단은 구체적인 기술적 표준모델이 없는 실정이다. 특히 전기분야 연구실에 대한 정기점검/정밀안전진단 관련 연구는 매우 취약한 상태로서 이에 대한 대책마련이 시급하다. 이에 대한 문제점을 파악하고 명확한 기준이 없는 점검항목, 점검방법, 필수 활용장비, 안전등급부여방법 등에 대한 구체적인 기준을 마련하였다. 또한, 기존 연구실험실의 전기전자분야 체크리스트를 검토, 분석하여 체크리스트개발연구를 수행하였다. 연구실험실에 실제 효율적으로 적용 가능하도록 구체적인 기준을 마련하여, 제시함으로서 전기안전 취약요인을 개선하도록 체계적이고 효율적인 표준모델을 제시하였다. 본 연구에서 개발된 전기분야 표준모델은 실제 필요한 점검항목에 대한 명확한 기준을 설정하여 모든 연구실에 공통으로 적용할 수 있도록 개발하여 정기점검과 정밀안전진단 수행 시 바로 실행 가능하도록 하였다. 이는 연구실의 전기사고방지를 위한 효율적인 점검뿐만 아니라, 연구실안전수준을 전반적으로 상승시킬 것이다.

누전차단기 동작시간 및 부동작 전류 특성 (A Study on the Cutoff time and the Malfunction Current Characteristics of RCDs)

  • 한운기;송길목;김영석;김동욱;최충석;이복영;박상태
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.61-65
    • /
    • 2005
  • This paper describes the cut off time and the current characteristics of virgin RCDs and deteriorated ones in the seashore. The RCDs(Residual Current Protective Devices) are used for protecting the human body from electrical shock and for preventing facility accidents. According to the Korean standards, the RCDs are installed in panel boards. When RCDs are installed outside, they must be enclosed inside waterproof cases. In the case that RCDs are employed at temporary power sites and electrical facilities on the road they are exposed to the external environment. As a result, the RCDs deteriorated in the seashore for 3 months showed high failure rate, while the virgin RCDs all complied with Korean Standard. Considering that the RCDs are used under exposed condition outside, the reliance of RCDs must be ensured by modifying the related regulations and codes and by developing improved advanced in their performance.

  • PDF

국내 보안등 운용실태 조사 및 유지관리성 검토 연구 (A Study on the Actual Operating Conditions of Guard Lamps and its Maintenance Problems)

  • 정종욱;정진수
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.89-95
    • /
    • 2008
  • 본 논문에서는 국내 설치된 보안등의 현장 운용실태를 조사하고 문제점을 검토하였다. 보안등은 기능상 국민의 야간 안전을 담당하는 설비로서 옥외에 설치되므로 자연적 요소로 인한 경년열화나 불특정다수인에 의한 훼손 등과 같은 고장원인을 항상 내포하고 있었다. 실제로 보안등과 관련된 크고 작은 인명사고가 매년 반복적으로, 또한 유사하게 발생해 왔음에도 불구하고 이를 위한 제도적 차원의 근본대책이 마련되지 않은 채 방치되다시피 관리되어 왔다. 본 연구는 보안등에 대한 최근의 운용실태를 조사하고 안전상의 문제점을 도출함으로써 국내의 보안등 유지 관리가 대체적으로 미흡하여 일반인이 안전사고 가능성에 항상 노출되어 있다는 경각심의 고취를 목적으로 하였으며, 현장답사 및 실무자, 업체관계자, 지방자치단체 내 보안등 업무담당자들과의 검토 연구를 통해 몇 가지 방안을 도출하였다.