• Title/Summary/Keyword: Electrical Shock

Search Result 404, Processing Time 0.031 seconds

A Study on Classification of Electric Shock Disasters and Countermeasures (전격재해의 유형 및 대책에 관한 연구)

  • 권영준;손병창;이명희;신승헌
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.47-55
    • /
    • 2000
  • In this modern age which electric energy is the fundamental source of energy in the industry, electric shock disasters are unavoidable. Although numerous efforts, time, and money have been invested to prevent such electric shock disasters, the number of electric shock disasters are on the increase. In this study, models for equivalent electric circuit are developed for the different types of electric shock which are classified into three groups. The objective of these models is to calculate the electric current flowing through the body at the time of the shock. Based on the analysis, countermeasures to prevent the shock are suggested. The data used in this study are based on 28 actual incidents which occurred in the Daegu area during January of 1995 through June of 1999. The results of this study can be used as a technical manual for workers treating electrical facilities.

  • PDF

A Study on Prediction of Fatigue Life and Shock Fracture for the Engine Base of Auxiliary Power Unit for Tracked Vehicle (보조동력장치 엔진 Base의 피로수명 예측 및 충격파손에 관한 연구)

  • Lee, Sang-Bum;Chung, Kyung-Taek;Shin, Jae-Ho;Jang, Hwan-Young;Suh, Jeong-Se
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.4
    • /
    • pp.86-92
    • /
    • 2008
  • This paper is to investigate the behavior of linear static structure stress, the fatigue and experimental shock fracture far engine base in the Auxiliary Power Unit to resolve its restricted electrical power problem. The shock fracture test was experimentally made under MIL standard criteria. The numerical results by finite element method had a good agreement with those from the shock test. The design data of predicting the fracture at the initial crack and the damage behavior of structure with shock and vibration load in the battle field can be obtained from shock test. In the functional shock test, the crack at the side parts of the engine base was found at peak acceleration of 40g.

Experimental Study on the Shock Response of a Cylindrical Structure with the Bolted Joint (조인트를 가진 원통형 구조물의 충격 응답에 관한 실험적 연구)

  • Jeon, Ho-Chan;Song, Ohseop
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.581-589
    • /
    • 2019
  • Guided missiles assembled with the bolted joint are subjected to various shock loading conditions while flying in the air and operating on the ground or platform. Especially, It is important to analyze the effect of the shock load on the structure because it affects the structure for a short duration time while its acceleration magnitude is quite large. In this study, mechanical shock tests on the structure with the bolted joint have been carried out to measure the acceleration changes of the structure against external shock loads by electrical exciter. Variation of dynamic characteristics of a structure with fastening methods and fastening forces has been investigated through Shock Response Spectrum analysis.

A Research on the Actual Conditions of the Electric Shock Hazard of a Guard Lamp (보안등의 감전 위험성에 관한 실태조사)

  • Jang, Tae-Jun;Jung, Yeon-Ha;Roh, Young-Su;Kwak, Hee-Ro;Choi, Chung-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.32-38
    • /
    • 2005
  • In this paper, guard lamps at three areas have been investigated to understand the actual conditions of the electric shock hazard of the guard lamps. Upon the basis of the obtained data, the actual conditions of the guard lamps were precisely analyzed in terms of the electric shock hazard. As a result of the investigation, it was turned out that many guard lamps were not installed in organized ways due to the lack of legal regulations, resulting in the increase of electric shock hazard. Therefore, it is necessary, from a point of electric shock protection view, to establish the regulations of equipment installation and management, which can be specifically applied to guard lamps.

Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current (누설전류로 인한 전기화재 및 감전사고 예방기법)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Sang-Ick;Kim, Jae-Hyun;Kang, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

The Qualitative Analysis through the Investigation of the Field Condition at Street Lamps on the Main Street (주요간선 도로에 설치된 가로등의 현장실태조사를 통한 정성적 분석)

  • Choi, Chung-Seog;Kim, Hyang-Kon;Han, Woon-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.101-108
    • /
    • 2005
  • When a heavy rain occurs, many electrical shock victims are produced every year because lamp poles are under water. In order to prevent electrical shock accidents at a street lamp, the investigation was carried out at real field conditions. The investigation was performed about the circuit configuration of a panel board, a wiring method, a grounding conductor, a lamp pole and so on. The related regulation was analyzed and the problems were presented. Also, the domestic and foreign things were compared and analyzed by the investigation of the field conditions, and the related standard was already revised. Through investigating the field conditions and analyzing the related regulation, it is intended to present the real data to establish more effective preventive measures against electrical shock accidents at a street lamp to be installed on the road. In the future, the analytical data can be applied to stabilize other electrical facilities on the road as well as a street lamp, and to reduce the electrical disasters.

Analysis of Electric Shock Accident on 4.16 kV Class Circuit breaker for Power Plant (발전소용 4.16 kV급 차단기에서 감전사고 사례 분석)

  • Park, Nam-Kyu;Song, Jae-Yong;Kim, Jin-Pyo;Goh, Jae-Mo
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.54-60
    • /
    • 2014
  • This paper describes electric shock accidents on a 4.16 kV class circuit breaker for power plant. Electric shock accidents mostly involve damage of human life, in comparison with electrical fire, rate of human death tend to be higher in electric shock accidents. Specially, in a high voltage facilities rate of human death comprised about 43.7% by electric shock accidents. If electric shock accidents happen in a 4.16 kV class circuit breaker for power plant, then the power plant discontinue power production. Electric shock accidents in a power plant have a great ripple effect such as an electric power shortage. In this paper, we analyzed electric shock accidents on a 4.16 kV class circuit breaker for power plant. From the analysis results, we confirmed a cause of electric shock accidents on a 4.16 kV class circuit breaker, it happened by defect of interlock equipment or occurrence of breakdown between first feeder contactor and shielding plate. In order to reduce electric shock accidents on a 4.16 kV class circuit breaker, the power plant should consider improvement of interlock equipment and insulation of feeder contactor in circuit breaker.

A study on the hazard of electric shock for 220V domestic receptacles (220V 가정용 콘센트에 대한 감전위험성 연구)

  • 한기붕;정세중;이대종
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.671-674
    • /
    • 2000
  • A children's electric shock accidents have broken out because children can easily insert sharp things in 220V receptacle holes. As the test result of pushing force, children's pushing force was about 2-4kg and the pushing force of sharp things was less than 2kg. Therefore, it is reason for electric shock that children's pushing force is large than pushing force of sharp things. We have measured insulation resistance for the receptacles of five companies during 50 weeks in humid condition. As these results, Insulation resistance for the receptacles of J. Co. had rapidly decreased with lapse of time. As the result for investigating the surface of receptacle by SEM and EDX, Al, Fe and Br, which weren't discovered at original form, were produced. Therefore, the receptacles of J. Co. should be the improved in the quality of insulating material because insulation resistance can be decreased in humid environment

  • PDF

An investigation on the actual condition of electrical facilities in domestic fountains (분수대 전기설비의 국내 적용실태분석)

  • Kim, H.S.;Kim, C.M.;Hwang, K.S.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.44-46
    • /
    • 2005
  • An Electrical facilities of fountain is one of the vulnerable facilities because it is exposed to water. Especially, some children enter the fountain and play in the water in the hot season. For example, death from electrical shock in fountain was reported in domestic and foreign papers. In this paper, we analyzed the riskiness of electrical shock on the basis of a fact-finding survey and comparing the domestic and international standard of electrical facilities in fountains.

  • PDF

Anti-shock Controller Design for Optical Disk Drive Systems with Nonlinear Controller (광디스크 드라이브 시스템을 위한 비선형 제어기를 이용한 Anti-Shock 제어기 설계)

  • Baek, Jong-Shik;Chung, Chung-Choo
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.675-677
    • /
    • 2004
  • This paper presents a nonlinear controller design for optical disk drive systems to improve anti-shock performance. The nonlinear anti-shock controller is added parallel to the original linear servo control loop. In the previous work, dead-zone nonlinear element is used for nonlinear controller and PID control method is used for linear controller. Although this strategy improves anti-shock performance, it has a narrow stability bound. In this paper, we propose dead-zone with saturation nonlinear element for the nonlinear controller. Since this nonlinear element improves stability margin, we can use higher gain of dead-zone than the controller with dead-zone only. In the linear controller design, we show that lead-lag control has improved stability margin over PID control. Numerical simulation results show that the proposed method can get better performance to the external shock than previously proposed method.

  • PDF