• Title/Summary/Keyword: Electrical Installations

Search Result 161, Processing Time 0.026 seconds

Protection coordination between residual current device and surge protective devices in low-voltage consumer's installations (저압 수용가 설비에서 누전차단기와 서지방호장치 사이의 보호협조)

  • Lee, Bok-Hee;Kim, Hoe-Gu;Park, Hee-Yeoul;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.75-81
    • /
    • 2013
  • In this paper, protection coordination between residual current devices and surge protective devices in low-voltage consumer's distribution systems are presented. In the case that a surge protrctive device(SPD) is located on the load side of an residual current device(RCD), when the surge is injected from the source side of the RCD, most of injected surge currents are split into the RCD and the protection coordination between the SPD and RCD is improper, three of 6 specimens experience unintended operation due to test impulse currents. Also when the surges is injected from the load side, a lot of the surge currents is split into the SPD, but a half of test specimens causes nuisance trip. Coordination between SPD and RCD is not valid. When installing SPD, it is important to select SPD after due consideration of the protection voltage level of metal oxide varistor embedded in RCD. It is expected that the results obtained from this work could be useful to improve the protection effects of SPD in low-voltage distribution systems.

Development of an Electronic Starter for Fluorescent Lamps (형광램프용 전자식 스타터의 개발)

  • 정영춘;곽재영;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.49-52
    • /
    • 1996
  • This paper reports the development of an electronic starter for fluorescent lamps, which is so smartly designed that can be used directly in existing installations. The key point of the design lies in the protection of lamp filaments by sufficient preheating and at the same time in the control of time constant for start-up circuit. The starter is consisted of three system parts: a rectifier pact, a switching part. and a gate control part. The characteristics of the developed electronic starter is compared with those of a conventional glow starter. As a result, blackening of lamps is almost reduced due to the stable and idealized start-up characteristics. And, furthermore, it is shown that its slaving time is shortened at about half the level of the conventional one and the starting power is also reduced.

  • PDF

A Light Characteristics of Mixed-Color LED for the Variable Color Temperature Street Light (가변색온도 가로등 구현을 위한 혼색LED의 조명특성)

  • Jeong, Byeong-Ho;Lee, Kang-Yeon;Choi, Youn-Ok;Kim, Dae-Gon;Kim, Nam-Oh;Min, Wan-Ki
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.142-147
    • /
    • 2009
  • Conventional HP(high pressure) sodium or Metal-halide lamps have a life span of around one year requiring at least annual replacement and maintenance. High Power LED lights require no regular maintenance further increasing savings on replacement bulbs, access equipment and labour costs. New installations benefit from a substantial reduction in the cost of expensive heavy duty cable required for sodium lighting. Especially, LED light can achieve variable color temperature, high functional performance in the field of street light. There are two main method to achieve variable color temperature function of the street light. one method is using RGB multi-chip LED, the other is using Orange-White LED method. In this paper, it was compare RGB Multi-chip LED with white-orange LED for there characteristics performance.

A Study on the Bidding Strategies of Combined Cycle Plants in a Competitive Electricity Market (경쟁적 전력시장에서 복합화력발전의 입찰전략에 대한 연구)

  • Kim, Sang-Hoon;Lee, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.694-699
    • /
    • 2009
  • Combined cycle plants which feature distinct advantages for power generation such as fast response, high efficiency, environmental friendliness, fuel flexiblity represent the majority of new generating plant installations across the globe. Combined cycle plants have different operating modes where the operating parameters can differ greatly depending which mode is operating at the time. This paper addresses the bidding strategy model of combined cycle plants in a competitive electricity market by using a characteristic of multiple operating modes of combined cycle plants. Simulation results of case studies show that an operating mode among multiple ones is selected strategically in generation bidding for more profit of generation company.

Development of a New Islanding Detection Method for Distributed Resources (분산 전원의 고립 운전 검출 기법의 개발)

  • Jang, Seong-Il;Kim, Gwang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.11
    • /
    • pp.506-513
    • /
    • 2001
  • The islanding detection for distributed resources (DR) becomes an important and emerging issue in power system protection since the distributed generator installations are rapidly increasing and most of the installed systems are interconnected with distribution network. In order to avoid the negative impacts from islanding operations of DR on protection, operation and management of distribution system, it is necessary to effectively detect the islanding operations of DR and rapidly disconnect it from distribution network. Generally, it is difficult to detect islanding operation by monitoring only one system parameter This paper presents a new logic based islanding detection method for distributed resources(DR) which are interconnected with distribution network. The proposed method detects the islanding operation by monitoring four system parameter: voltage variation, phase displacement, frequency variation, and the variation of total harmonic distortion(THD) of current; therefore, it effectively detects island operation of DR unit operating in parallel with the distribution network. We also verified the efficiency of the proposed algorithm using the radial distribution network of IEEE 34 bus model.

  • PDF

Analyses of Earth Surface Potentials Depending on Soil Structures (대지구조에 따른 대지표면전위의 분석)

  • Lee, Bok-Hee;Baek, Young-Hwan;Jung, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1796-1801
    • /
    • 2007
  • This paper presents electric potential rise on the surface of the earth due to ground currents. It is the aim of this paper to propose fundamental data relevant to the earth surface potentials depending on the soil structures. The earth potential rise, touch and step voltages in the immediate vicinity of the ground rod of a distribution pole were measured and analyzed. The results described in this paper are based on laboratory measurements which were intended to simulate conditions existing in actual installations. As a result, the earth surface potential rise, touch and step voltages strongly depend on the soil structure. The highest earth surface potential occurred in the vicinity of the top of ground rod. When the ground rod was installed in the distance range of $1{\sim}1.5\;m$ from distribution pole, the highest touch voltages appeared near the place of 1 m on the straight line connecting the distribution pole to ground rod.

Harmonics Measurement of Evaluation of KJ Road Tunnel Installations (KJ 도로터널시설물의 고조파 실측 및 평가)

  • Wang, Yong-Peel;Kim, Se-Dong;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.87-93
    • /
    • 2011
  • Nonlinear loads including lighting fixtures generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probabilistic approach is the most commonly used method to solve time varying harmonics. In this paper the time varying harmonics of lighting loads are evaluated by international harmonic standards(IEC 61000-3-6).

Deterioration of Elevator Components in Apartments (승강기의 노후화 현상 조사 연구)

  • Lee, Ki-Hong;Seo, Man-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.338-341
    • /
    • 2007
  • This paper surveyed the deterioration phenomena of elevator system being operated in Apartments. It was proved that oil leakage, gear abrasion and metal corrosion are the main deterioration phenomena and the number of breakdown was increasing rapidly with 8 years elapsed from installations

  • PDF

Development of a optimal design algorithm for building electrical installations introducing the energy conversation grade (에너지 효율화를 위한 등급별 분류방법을 도입한 건축물전기설비의 최적설계 알고리즘 개발)

  • Kim, Jung-Hun;Ahn, Duck-Woo;Yang, Hai-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.691-693
    • /
    • 2005
  • 현재 우리나라에서 수행되는 전기설계는 체계화가 되어있지 않고 기관, 단체 또는 개개인의 경험에 따라 주관적으로 설계가 되고 있다 따라서 일관성이 없고 에너지 절약에 대한 강제성도 일부에 국한되어 효율적인 에너지 관리가 안 되고 있다. 이와 같은 전기설계체제를 객관화하여 이를 알고리즘화를 통하여 프로그램을 구축하고자 하는 시도가 필요하다. 기존의 전문가의 경험을 바탕으로 한 최적설계절차를 프로그램화하기 위하여 전기관련 기기를 에너지 절약별 등급화하여 등급화별 최적 수변전설비용량을 결정할 수 있는 알고리즘을 개발하고 이를 프로그램 하고자 한다.

  • PDF

Surface Potential Distribution according to Grounding Electrode Shapes (접지전극 형상에 따른 대지표면전위분포)

  • Baek, Young-Hwan;Lee, Bok-Hee;Li, Feng;Yang, Soon-Man;Lee, Kyu-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1360-1361
    • /
    • 2008
  • This paper presents the surface potential rise distribution near grounding electrodes produced by ground fault currents. The small-scale model with the foundation pedestal in hemispherical tank was used to simulate the ground fault condition of the electrical installations for street lamps. When entering the fault current through the test ground electrode, surface potential rise, potential gradient, touch and step voltages for different grounding electrode shapes were measured, and the results obtained were discussed.

  • PDF