• Title/Summary/Keyword: Electrical IT Equipment

Search Result 1,192, Processing Time 0.035 seconds

Development of Watt-Hour Meter Exchange Equipment without Outage (전력량계 무정전 교체장치 개발에 관한 연구)

  • Jung, Tae-Hoon;Cho, Sung-Min;Shin, Hee-Sang;Lee, Hee-Tae;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.99-103
    • /
    • 2009
  • This paper presents equipment that can exchange watt-hour meters without outage for customers, It is simpler than other methods to avoid outage during exchange. Furthermore, it has protective function to ensure customer's facility from engineer mistake. Because of good point mentioned above, it can improve efficiency and safety. Adopting developed equipment can ensure continuous electric power supply to customers.

The Study on Measuring the Impedance of the Noise Source (잡음원의 임피던스의 측정에 관한 연구)

  • 박병욱
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.53-56
    • /
    • 2000
  • An Electrical equipment is the noise source which makes a noise. So the optimally designed filter should be inserted in the equipment in order to reduce the noise. The noise source impedance is varied according to the frequency It effects on the CE noise. Knowing the magnitude of its impedance and inserting an EMI filter in the equipment we can estimate the insertion loss of the filter. SO it helpful in designing the EMI filter. The measurement method of a noise source impedance is proposed and verified by experiment.

  • PDF

Evaluation of life Expectancy of Power System Equipment Using Probability Distribution (확률분포를 이용한 전력설비의 기대여명 추정)

  • Kim, Gwang-Won;Hyun, Seung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.49-55
    • /
    • 2008
  • This paper presents a novel evaluation method of life expectancy of power system equipment. The life expectancy means expected remaining lifetime; it can be usefully utilized to maintenance planning, equipment replacement planning, and reliability assessment. The proposed method is composed of three steps. Firstly, a cumulative probability for future years is evaluated for targeted age year. Secondly, the cumulative probability is modeled by well-blown cumulative distribution function(CDF) such as Weibull distribution. Lastly, life expectancy is evaluated as the mean value of the model. Since the model CDF is established in the proposed method, it can also evaluate the probability of equipment retirement within specific years. The developed method is applied to examples of generators of combined cycle power plants to show its effectiveness.

The Study for change plane to apply CBTC(Communication Based Train Control) on the subway (통신을 이용한 열차제어시스템의 기존 도시철도 적용을 위한 절체방안연구)

  • Kim, You-Ho;Lee, Soo-Hwan;Yoo, Jong-Cheon;Lee, Young-Hoon;Baek, Jong-Hyen
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.365-367
    • /
    • 2003
  • In this study, we studied the change plan essentially used for improving the existing railroad signal system. For mixed installation with the existing equipment by introducing new equipment in the city railroad currently operated, it is required to establish a plan depending on the change and to present a plan for change. For the change, since it is necessary to classify ground equipment and onboard equipment and change must be carried out considering performance and functions of each equipment, we classified and studied each equipment for plans of change.

  • PDF

Benefit-Cost Analysis in Accordance with Replacement of Electrical Cooling System by Gas Cooling System using the California Standard Test (캘리포니아 표준테스트 방법을 사용한 전기냉방기기의 가스냉방기기 대체에 따른 편익비용분석)

  • Park, Rae-Jun;Song, Kyung-Bin;Won, Jong-Ryul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1774-1781
    • /
    • 2012
  • There are some efforts to improve the performance of electrical heat pump(EHP) and replace it with an alternative cooling equipment such as gas engine-driven heat pump(GHP), a gas cooling equipment, in order to solve the problem of summer electricity supply through reducing the summer electricity peak. This paper analyzes cost-benefit in accordance with replacement of electrical cooling system by gas cooling system using california standard test and sensitivity analysis of some scenarios.

A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment (배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Kim, Jae-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.

Development of UV-IR Camera using IR Module and Improved UV Filter Transmittance (투과율 향상 UV 필터와 IR 모듈을 이용한 자외선-적외선(UV-IR) 카메라 개발)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il;Kim, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.37-43
    • /
    • 2012
  • UV-IR diagnostic technology is being used for predictive maintenance of high voltage equipment together with IR-thermography and ultrasonic devices. In this paper, the UV-IR camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. UV-IR camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. In a distance of 5m with the UV-IR it is possible to detect partial discharge with a PD level of 2.5 pC and a RIV(Radio Influence Voltage) level of $3.6dB{\mu}V$.

The Magnetic Properties of Electrical Steel for Rotating Machine according to the Specimen

  • Choi, Yun-Yong;Chin, Jun-Woo;Hong, Jung-Pyo
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.209-214
    • /
    • 2016
  • This paper analyzes the magnetic property according to the machined shape of steel material with non-oriented silicon steel (50PN470/50A470), that is most commonly used in the design of electrical equipment. Toward this end, specimens were produced and divided into Bar-Specimen (Epstein Frame Tester) and Ring-Specimen (Toroidal Ring Tester). The characteristics of the electrical Silicon steel were measured using the instruments solely dedicated to measuring each specimen. The core loss of the Bar-Specimen, which is commonly used, was found to be less than that of the Ring-Specimen. This is a very important design factor in achieving the objectives of improving the product efficiency and predicting the performance of electrical equipment. It serves as a critical point of view in order to reduce the error between design value and product value. A comparative analysis was conducted regarding various characteristics (Hysteresis, B-H characteristic, Iron loss, Minor loop, Coercive force, Residual magnetic flux density, etc.) of the electrical silicon steel considered in the design of the electrical equipment according to the specimen.

Advanced Intensity Measures for Probabilistic Seismic Demand Model of Nonstructural Components Considering the Effects of Earthquake (지진에 의한 영향을 고려한 비구조물 확률론적 내진응답모델링을 위한 향상된 지진강도)

  • Hur, Ji-eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.8-14
    • /
    • 2017
  • Nonstructural components, such as electrical equipment, have critical roles in the proper functionality of various infrastructure systems. Some of these devices in certain facilities should operate even under strong seismic shaking. However, it is challenging to define each mechanical and operational failure and determine system failure probabilities under seismic shaking due to the uncertainties in earthquake excitations and the diversity of electrical equipment, among other factors. Therefore, it is necessary to develop effective and practical probabilistic models for performance assessment of electrical equipment considering variations in equipment features and earthquakes. This study will enhance the understanding of the effect of rocking behavior on nonstructural equipment, and linear-to-nonlinear behavior of restrainers. In addition, this study will generate probabilistic seismic demand models of rigid equipment for a set of conventional and novel intensity measures.

Brief study on Restriction of Hazardous Substances Directive (RoHS) (유해물질(有害物質) 제한지침(制限指針)(Restriction of Hazardous Substances Directive, RoHS)의 현황(現況))

  • Kumar, J. Rajesh;Lee, Jin-Young;Kim, Joon-Soo;Shhn, Jeong-Soo
    • Resources Recycling
    • /
    • v.17 no.6
    • /
    • pp.3-9
    • /
    • 2008
  • The Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment commonly referred to as the Restriction of Hazardous Substances Directive or RoHS was adopted in February 2003 by the European Union. The RoHS directive took effect on 1 July 2006, and is required to be enforced and become law in each member state. This directive restricts the use of six hazardous materials in the manufacture of various types of electronic and electrical equipment. It is closely linked with the waste electrical and electronic equipment directive (WEEE) 2002/96/EC which sets collection, recycling and recovery targets for electrical goods and is part of a legislative initiative to solve the problem of huge amounts of toxic e-waste.