A Study on the Lightning Surge Protection Methods on Transmission System and Substation (송전계통 및 변전소 뇌서지 보호방안 연구)

  • Kim Jae-Kwan;Jung Chae-Kyun;Lee Jong-Beom;Cho Han-Goo;Seo Je-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.6
    • /
    • pp.279-285
    • /
    • 2005
  • The lightning causes the damage of power system equipments as well as large power failure. Therefore, the insulation design should be established not only to decrease the damage of the facilities itself but also to increase the reliability of electric power system. This paper describes the useful way applying underbuilt ground wire and guy wire in transmission tower that safely protect the substation equipments. One or more shield wires under the phase conductor will not intercept lightning stroke, but they may improve reduce lightning voltages almost as effectively as if they were above the phase conductors. And the guy wires will mitigate the tower surge response. These would not only reduce backflashover possibility but also minimize crest and duration of surges entering the substation. EMTP is used to analyze the efficiency of the proposed methods.

The Stress Analysis of the Cross Beam of the Electric Car-body according to the Change of Location and Shape of Circular Hole (원공 위치와 형상 변화에 따른 전동차 크로스 빔의 강도해석)

  • Jeon, Hyung-Yong;Sung, Rak-Won;Han, Geun-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.9
    • /
    • pp.9-17
    • /
    • 1999
  • This investigation is the result of the structural analysis by finite element method for optimal design of the cross beam with circular holes of the electric car-body. in order to install the air pipe and electric wire pipe that correspond signal between electric machines for the control system and to reduce the weight of the electric car-body, several circular areas from a cross beam should be taken off. What we want to perform is the optimal design of a cross beam with circular holes to posses equal stress in comparison with no hole cross beam. first, no hole cross beam as basic modal be chosen, executing the analysis, reviewing the distribution of stress and displacement at each location. several parameter should be adopted from the cross beam geometry like the location and shape of the hole to affect the maximum stress and displacement. So the analysis was executed by finite element analysis for finding optimal design parameter to the change of the location and shape of the circular hole. finally, the optimal design of the cross beam with circular holes was obtained and the maximum equivalent stress was compared with no hole cross beam at each location.

  • PDF

A Study on the Topology Optimization of Electric Vehicle Cross beam using an Optimality Criteria Method in Determination of Arranging Hole( I ) (원공배열 결정에 최적기준법에 의한 전동차 크로스 빔의 위상최적화에 관한 연구( I ))

  • 전형용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.11
    • /
    • pp.137-145
    • /
    • 2002
  • Electric vehicle body has to be subjected to uniform load and requires auxiliary equipment such as air pipe and electric wire pipe. Especially, the cross beam supports the weight of passenger and electrical equipments. a lightweight vehicle body is salutary to save operating costs and fuel consumption. Therefore this study is to perform the size and the shape optimization of crossbeam for electric vehicle using the method of topology optimization to introduce the concept of homogenization based on optimality criteria method which is efficient for the problem having the number of design variables and a few boundary condition. this provides the method to determine the optimum position and shape of circular hole in the cross beam and then can achieve the optimal design to reduce weight.

Technology development on automatic changeover system in neutral section with energized condition of electric railway catenary system (절연구간 무접점 자동 전원절체 통과시스템 기술개발)

  • Hong, Hyun-Pyo;Han, Moon-Seob;Seo, Myung-Seok;Shin, Myong-Cheol;Yoon, Yong-Han;Kim, Jae-Chul
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.498-506
    • /
    • 2010
  • The neutral section was installed in order to prevent conflict with different phase angle source in electric railway catenary system. The speed of electric train reduced due to coasting operation by notch off when it passed the neutral section. And, the catenary wire was damaged and the accident might be happened because of the arc generation when the electric train passed the neutral section with notch on condition. This project has a goal to develop the automatic changeover system using by noncontactless semiconductor device in neutral section of catenary system so that the train pass as notch-on condition. In this first year, we obtain as following results such as domestic and international systems applications and completion requirements, development and analysis of stability for automatic changeover system, design of static switching device on automatic changeover system in neutral section and drawing up interface design and specifications according to equipment.

  • PDF

A Study on the Topology Optimization of Electric Vehicle Cross beam using an Optimality Criteria Method in Determination of Arranging Hole (원공배열 결정에 최적기준법에 의한 전동차 크로스 빔의 위상최적화에 관한 연구)

  • 전형용;천홍정;송시엽;최중호
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.876-883
    • /
    • 2002
  • Electric vehicle body has to be subjected to uniform load and requires auxiliary equipment such as air pipe and electric wire pipe. Especially, the cross beam supports the weight of passenger and electrical equipments. a lightweight vehicle body is salutary to save operating costs and fuel consumption. Therefore this study is to perform the size and the shape optimization of crossbeam fur electric vehicle using the method of topology optimization to introduce the concept of homogenization based on optimality criteria method which is efficient for the problem having the number of design variables and a few boundary condition. this provides the method to determine the optimum position and shape of circular hole in the cross beam and then can achieve the optimal design to reduce weight.

  • PDF

A Study on Circuit Topology Design for Alarm System Development of Series Arc Fault (직렬 아크사고 경보시스템 개발을 위한 회로 토플로지 설계에 관한 연구)

  • Jung, M.S.;Kwak, D.K.;Choi, J.K.;Kim, K.S.;Park, Y.J.
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.38-39
    • /
    • 2016
  • Most of fires are electric fires and 78.65% of those fires are caused by electric arc fault. This series arc fault can be caused not only by decrepit wire, pressed wire or contact badness etc. anywhere we use electricity. There are signs of heat release and flame discharge before the arc fire accident happens. This paper proposes a circuit topology for alarm system of series arc fault. We also verify the qualification of system through various arc fault simulator.

  • PDF

Design of Heat Pump for Temperature Control of Sealed Electric Box (밀폐 형 전장 박스 온도 제어를 위한 히트 펌프 설계)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.110-114
    • /
    • 2020
  • In this paper, a heat pump using a Peltier device was developed for heat dissipation in a sealed electric box. The heat pump was designed with a cooling fin attached to both sides of the Peltier device, and a fan was mounted on the cooling fin on the hot side to increase the efficiency. The heat dissipation efficiency could be improved by directly connecting the electronic component having high heat to the cooling fin using a heat conducting wire. The fabricated heat pump was designed to operate only in the temperature range set by the temperature control system to improve the problem of high power consumption of the Peltier element.

Adaptive DC-link Voltage Control for Shunt Active Power Filter

  • Wang, Yu;Xie, Yun-Xiang
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.764-777
    • /
    • 2014
  • This study analyzes the mathematical relationship between DC-link voltage and system parameters for shunt active power filters (APFs). Analysis and mathematical deduction are used to determine the required minimum DC-link voltage for APF. A novel adaptive DC-link voltage controller for the three-phase four-wire shunt APF is then proposed. In this controller, the DC-link voltage reference value will be maintained at the required minimum voltage level. Therefore, power consumption and switching loss will effectively decrease. The DC-link voltage can also adaptively yield different DC-link voltage levels based on different harmonic currents and grid voltage levels and thus avoid the effects of harmonic current and grid voltage fluctuation on compensation performance. Finally, representative simulation and experimental results in a three-phase four-wire center-split shunt APF are presented to verify the validity and effectiveness of the minimum DC-link voltage design and the proposed adaptive DC-link voltage controller.

Design and Fabrication of Light-Weight Composit Bus Bar (복합경량 부스바의 설계 및 제작)

  • Bae Joon-Han;Bea Duck-Kweon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.334-340
    • /
    • 2006
  • Copper is widely used in electric wire, cable, conductor in electric devices. As the demand for electric power is increasing rapidly, electric power devices are getting amazingly bigger and complicated. The using of light-weight conductor can reduce the size and making cost of the electric devices. In high-frequency application, Electric current in a conductor tends to shift to the surface of the conductor, resulting in an uneven current distribution in the inner conductor. In the extreme case the current may essentially concentrate in the 'skin' of the inner conductor as a surface current. In high frequency application, therefore, inner area of copper conductor may replace with aluminum conductor, which reduces the weight of conductor. This paper describes the manufacture and evaluation of composite conductors made of copper and aluminum. The optimum extruding ratio was 16 at $300^{\circ}C$. The electrical resistance of manufactured composite bus bar was $57{\mu}{\Omega}$ at DC and $49.5{\mu}\{Omega}$ at 300Hz.

Case Study on AUTOSAR Software Functional Safety Mechanism Design: Shift-by-Wire System (AUTOSAR 소프트웨어 기능안전 메커니즘 설계 사례연구: Shift-by-Wire 시스템)

  • Kum, Daehyun;Kwon, Soohyeon;Lee, Jaeseong;Lee, Seonghun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.6
    • /
    • pp.267-276
    • /
    • 2021
  • The automotive industry and academic research have been continuously conducting research on standardization such as AUTOSAR (AUTomotive Open System ARchitecture) and ISO26262 to solve problems such as safety and efficiency caused by the complexity of electric/electronic architecture of automotive. AUTOSAR is an automotive standard software platform that has a layered structure independent of MCU (Micro Controller Unit) hardware, and improves product reliability through software modularity and reusability. And, ISO26262, an international standard for automotive functional safety and suggests a method to minimize errors in automotive ECU (Electronic Control Unit)s by defining the development process and results for the entire life cycle of automotive electrical/electronic systems. These design methods are variously applied in representative automotive safety-critical systems. However, since the functional and safety requirements are different according to the characteristics of the safety-critical system, it is essential to research the AUTOSAR functional safety design method specialized for each application domain. In this paper, a software functional safety mechanism design method using AUTOSAR is proposed, and a new failure management framework is proposed to ensure the high reliability of the product. The AUTOSAR functional safety mechanism consists of memory partitioning protection, timing monitoring protection, and end-to-end protection. The fault management framework is composed of several safety SWCs to maintain the minimum function and performance even if a fault occurs during the operation of a safety-critical system. Finally, the proposed method is applied to the Shift-by-Wire system design to prove the validity of the proposed method.