• Title/Summary/Keyword: Electric-field Intensity

Search Result 294, Processing Time 0.025 seconds

The Crack Problem for Functionally Graded Piezoelectric Ceramic Strip (기능 경사 압전 세라믹 스트립의 균열에 관한 연구)

  • 신정우;김성찬
    • Composites Research
    • /
    • v.15 no.4
    • /
    • pp.37-42
    • /
    • 2002
  • We consider the problem of determining the singular stresses and electric fields in a functionally graded piezoelectric ceramic strip containing a Griffith eccentric crack under anti-plane shear loading with the theory of linear piezoelectricity. Fourier transforms are used to reduce the problem to the solution of two pairs of dual integral equations, which are then expressed to a Fredholm integral equation of the second kind. Numerical values on the stress intensity factor and the energy release rate are obtained.

Eccentric Crack in a Piezoelectric Strip Under Electro-Mechanical Loading

  • Lee, Kang-Yong;Shin, Jeong-Woo;Kwon, Soon-Man
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • We consider the problem of determining the singular stresses and electric fields in a piezoelectric ceramic strip containing a Griffith eccentric crack off the center line under anti-plane shear loading with the theory of linear piezoelectricity. Fourier transforms are used to reduce the problem to the solution of two pairs of dual integral equations, which are then expressed to a Fredholm integral equation of the second kind. Numerical values on the stress intensity factor and the energy release rate are obtained, and the influences of the electric fields for piezoelectric ceramics are discussed.

  • PDF

Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner (2단 평행판 전기집진기의 방전부 특성 실험)

  • Kim, I.S.;Lee, J.O.;Kim, Y.J.;Choi, H.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF

Characteristics of TV Ghost Interference from Extra High Voltage Transmission Line (초고압 송전선로에 의한 TV Ghost 장해 발생 특성)

  • Ju, Mun-No;Yang, Gwang-Ho;Lee, Dong-Il;Sin, Gu-Yong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.412-417
    • /
    • 2000
  • TV ghost interference can be described as passive interference by the conducting part of transmission lines. In order to survey this interference from large-sized overhead EHV (extra high voltage) transmission line, TV reception quality was measured in the vicinity of that before and after construction. Instrumentation system was composed of ghost analyzer, TV received field intensity meter, VHF/UHF antennas, TV monitor and so on. The system is installed inside the vehicle. TV field intensity and PDUR (Perceived Desired wave to Undersired wave Ratio) are measured to evaluate TV ghost by using the system and vehicle. As the results, the useful data, which can be used to evaluate the effect of TV ghost interference from transmission lines could be obtained. In this paper, it is shown that the range of TV ghost interference from transmission lines can vary according to the frequency of TV electromagnetic wave, an incidence angle to the line and the other conditiions. At present, we are making efforts to establish a PDUR guideline for transmission lines.

  • PDF

Rigorous Analysis of Viewing Zone for 3D Display with Electric-field-driven Liquid Crystal Lens (액정 전계 렌즈 기반 3차원 디스플레이 장치의 엄정한 시청영역 분석)

  • Kim, Tae-Hyeon;Kim, Bong-Sik;Park, Woo-Sang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.494-498
    • /
    • 2016
  • In this paper, we proposed the 3-dimenstional (3D) analysis for calculating the optical characteristics of an autostereoscopic display with electric field driven liquid crystal (ELC) lens. From 3D analysis considering the slanting of lens, we calculate the cross-talk of each images and the distortion of viewing zone. Using geometric opics and extended Jones matrix method (EJMM), phase retardation of ELC lens according to position is calcuated and then optical path difference in 3D space considering tilt and azimuth angle of incident light is gotten. Then, intensity distribution is presented in the space. Through camparing the intensity distribution using ideal lens with the ELC lens, we identify the noise and image distortion of ELC lens. As a result, this analysis is expected to provide optimum design conditions for realistic and rigorous 3D display with ELC lens.

Analysis of Soil Ionization Behaviors under Impulse Currents

  • Lee, Bok-Hee;Park, Geon-Hun;Kim, Hoe-Gu;Lee, Kyu-Sun
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.98-105
    • /
    • 2009
  • This paper presents the characteristics of soil ionization for different water contents, and the parameters associated with the dynamic properties of a simple model grounding system subject to lightning impulse currents. The laboratory experiments for this study were carried out based on factors affecting the soil resistivities. The soil resistivities are adjusted with water contents in the range from 2 to 8% by weight. A test cell with a spherical electrode buried in the middle of the hemispherical container was used. As a result, the electric field intensity $E_c$ initiating ionization is decreased with the reduction of soil resistivities. Also, as the water content increased, the pre-ionization resistance $R_1$ and the post-ionization resistance $R_2$ became lower with increasing current amplitude. The time-lag to ionization $t_1$ and the time-lag to the second current peak $t_2$ at high applied voltages were significantly shorter than those of low applied voltages. It was found that the soil ionization behaviors are highly dependent on the water content and the applied voltage amplitude.

A Study on the Characteristics of the Electric Field and Electromagnetic Loss according to Bus Bar Size for a cost-effective 24kV High Voltage Switchgear (비용 효율이 높은 24kV급 고압배전반 개발을 위한 Bus Bar 사이즈에 따른 전·자기 손실 특성 분석)

  • Hong, Jonggi;Heo, Jeong Il;Nam, Seokho;Kang, Hyoungku
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.4
    • /
    • pp.220-224
    • /
    • 2012
  • The analysis on the bus bar effect is conducted to develop a cost effective 24kV/2,000A switchgear. The temperature enclosures and bus bars could rise due to several heat sources such as eddy current losses and copper losses. Therefore, a study on the characteristics of the electric field intensity and electromagnetic loss according to the bus bar size in a bus bar compartment is essential to design a electrically reliable high voltage switchgear. It is investigated that the electromagnetic influence to the temperature rising and the dielectric stability according to various bus bar sizes by using finite element method(FEM). The electric field intensity and electromagnetic loss according to various bus bar sizes are calculated to design a reliable and a high voltage switchgear. As results, it is found that the electromagnetic loss and the dielectric stability of bus bar could be determined by a bus bar size. It means that a cost effective 24kV/2,000A high voltage switchgear could be developed by selecting the proper size of a bus bar. Also, it is recognized that the electromagnetic characteristics according to various bus bar sizes in order to design an electrically stable high voltage switchgear when the enclosure size is determined as a fixed value. Futhermore, studies on the various nominal voltage class and bus bar sizes will be conducted to develop a cost effective high voltage switchgear.

A Study on the Fabrication of Integrated Optical Electric-Field Sensor and Performance utilizing Asymmetric $Ti:LiNbO_3$ Mach-Zehnder Interferometer (비대칭 $Ti:LiNbO_3$ Mach-Zehnder 간섭기를 이용한 집적광학 전계센서 제작 및 성능에 관한 연구)

  • Ha, Jeongho;Jung, Hongsik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.128-134
    • /
    • 2012
  • The performance evaluation and fabrication of integrated-optic electric-field sensor utilizing $Ti:LiNbO_3$ asymmetric Mach-Zehnder intensity modulator with a push-pull lumped electrode and a plate-type probe antenna to measure an electric field strength is described. The modulator has a small device size of $46{\times}7{\times}1\;mm$ and operates at a wavelength $1.3{\mu}m$. The devices are simulated based on the BPM software and fabricated utilizing Ti-diffused $LiNbO_3$ channel optical waveguides. The minimum detectable electric field is 1.02 V/m and 6.91 V/m, corresponding to a dynamic range of ~35 dB and ~10 dB at the frequencies of 500 KHz and 5 MHz, respectively.

Effect of continuous pulsed electric fields treatments on quality of apple juice (사과주스의 품질에 미치는 pulsed electric field 연속 처리효과)

  • Ahn, Seong-Hwan;Lim, Jeong-Ho;Kim, Young-Ho;Chung, Suk Jin;Park, Kee-Jai
    • Food Science and Preservation
    • /
    • v.20 no.5
    • /
    • pp.650-658
    • /
    • 2013
  • Apple juices were sterilized by continuous pulsed electric field (PEF) treatments of pulse width of 25 ${\mu}s$ at electric field intensity of 20.0 kV/cm, and with the varied pulse frequencies of 35 Hz (40 kJ/L), 55 Hz (70 kJ/L), 72 Hz (100 kJ/L) and 85 Hz (130 kJ/L). The PEF treatments of apple juice reduced the microbial counts from 5.3 log CFU/mL of initial state to 3.0 log CFU/mL after PEF treatment at energy density of 130 kJ/L. Also yeast and fungi after PEF treatments were reduced from 5.3 log CFU/mL to 3.0 log CFU/mL and Escherichia coli were from 5.3 log CFU/mL of initial state to 4.7 log CFU/mL to < $10^1$ CFU/mL. The soluble solids and free sugars did not significantly differ (p<0.05) depending on conditions of PEF treatment. The total phenolic contents and antioxidant activity such as the DPPH and ferric reducing antioxidant power (FRAP) by PEF treatments were significantly partly reduced, but the PEF-reduced value came in smaller quantities than the heat treatment at $65^{\circ}C$. The iterative PEF treatments with pulse width of 25 ${\mu}s$ and pulse frequency of 85 Hz at electric field intensity of 20.0 kV/cm showed limited in microbial reduction. Also, total phenolic contents and antioxidant activity such as DPPH and FRAP, significantly decreased depending on treatment numbers of PEF (p<0.05).

Assessment of Possibility on the Human Risk for the Electromagnetic Field of Unbalanced Two Coupled Three-phase Transmission Line Using Fuzzy Theory (퍼지이론을 이용한 3상 2회선 불평형 송전선로에서의 전자계에 대한 인체 위험 가능성평가)

  • Kim, Sang-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.22-28
    • /
    • 2006
  • This paper presents assessment of possibility on the human risk for the electromagnetic field of unbalanced two coupled three-phase transmission line using fuzzy theory. Three phase load flow program was developed which employed a Newton-Raphson method as a tool to analyze system unbalanced. This research presents a method of handling two coupled three phase transmission system unbalance analysis and unbalanced power demand as a function of voltages. As the results of case study, in case of 345[kV] T/L, the electric field intensity was 10.9540[kV/m], magnetic field intensity was 0.2567[G] in severest case. The results showed that the membership of a proposition fuzzy '10.9540 [kV/m] is hazardous' is 0.6349. As the analytic results using the fuzzy qualifier term, the membership in case of very false is 0.1379 and fairly false is 0.6124, respectively. In assessment of fuzzy measure possibility for the electromagnetic field, this paper used probability of fuzzy arid measure of fuzziness technique.