• Title/Summary/Keyword: Electric safety

Search Result 1,827, Processing Time 0.04 seconds

Analysis of Ignition Time/Current Characteristics and Energy when Series Arc-Fault Occurs at Rated 220 V (220 V 직렬 아크고장발생 시 점화 시간/전류 특성 및 에너지 분석)

  • Ko, Won-Sik;Moon, Won-Sik;Bang, Sun-Bae;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1184-1191
    • /
    • 2013
  • Probability of ignition due to arc-fault and energy of the arc-fault for the case of applying serial arc-fault interruption time of 120 V defined in UL 1699 to the voltage of 220 V of domestic condition and also for the case of applying it to the HIV wire type are analyzed. It has been confirmed that when the arc-fault occurs under 5 A, 10 A, and 20 A. Probability of ignition for the three different current conditions is 0.74(74%), 0.48(48%), and 0.32(32%) respectively for respective interruption time within 1 sec, 0.4 sec, and 0.2 sec. We discover that when we apply the same arc interruption time for 120 V defined in UL 1699 to the domestic environment of 220 V. The probability of ignition increases from 1.5% for 120 V condition to as much as 74% for 220 V condition. Conclusively, if we apply the standard for the serial arc-fault interruption time defined in UL 1699 for 120 V to the domestic condition of 220 V, the fire prevention effect of electric fire due to arc-fault equal to that of UL standard of 120 V can not be achieved.

A Study on the Management of Subway Structure as an Underground Facility (지하 시설물로서의 지하철 구조물 관리 방안에 관한 연구)

  • 김충평;김감래
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.1
    • /
    • pp.21-28
    • /
    • 1997
  • Since beginning of subway construction in 1974, for supplying the demand for increasing urban traffic and solving the traffic jam due to expansion of society and elevation of an individual income, the $1^{st}\;and\;2^{nd}$ construction have been almost done and $3^{rd}$ has been driving forward. However, according to an increment of com-mon usage with the passage of time, structures are superannuated and the amount of improvement and repairs keeps on increasing continuous. And many problems are taking place at underground space because of new constructions for underground facilities such as urban gas, electric power, waterworks, and sewerage. In consequence. The consideration of a counterplan for safety is required deeply This study analyzed problems on maintenance of structure about $1^{st}$ class subway, and will present means that a manage civil structures scientifically and systematically by using GSIS concept that imported into several organizations for facility management recently as making digital graphic elements and historic data into a database rather than using an old method - documents and paper drawings.

  • PDF

Microbial changes and physico-chemical properties of beef and pork loin with microwave treatment (마이크로파 처리한 소고기 및 돼지고기의 미생물 변화 및 이화학적 특성)

  • Lee, Kyong-Ae;Byoun, Kwang-Eui
    • Korean Journal of Human Ecology
    • /
    • v.14 no.1
    • /
    • pp.217-221
    • /
    • 2005
  • In this study, the effect of microwave treatment on physico-chemical properties and microbial changes of beef and pork loin was investigated. Beef and pork were heated in microwave with an adjusted electric output at 500 W and operating frequency 2,450 MHz. The beef and pork samples were treated with microwave for 10 s or 20 s at 50% duty cycle. Drip losses and TBA values of beef and pork samples increased due to the microwave treatment. The samples became darker and more yellowish through microwaves, whereas their redness was unchanged. Microbial content of beef and pork samples declined as the treatment time increased. When pork samples were heated in a microwave oven, organisms were reduced by 2 log cycles in 20 s. It was concluded that a 20 second-long microwave treatment can great1y enhance the microbial safety of the pork sample.

  • PDF

A Study on the Acoustic Absorption Panel by the Theory of Resonator (공명 원리를 이용한 흡음벽에 관한 연구)

  • Yu, Young-Hun;Yi, Jong-Keun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.125-129
    • /
    • 2006
  • It is very important to remove the noise levels made by an electric home appliance and machines they are located in the auditory region. The noise of ship engine room is known as it is not easy to lower so the working environment of the engine room is the worst condition because the improvement for the noise seemed insignificant and the hearing loss is occurred. As the monitoring equipment and an intelligent control system are improved rapidly the main engine of the ship can be enclosed with an acoustic barrier and any other absorbtion equipment. In this study, the sound absorbtion barrier is experimentally researched by change the volume and the length of the neck for the Helmholtz resonator as the resonator can absorb the noise effectively.

  • PDF

Calculation of Induced Current in the Human Body by Magnetic Field in the 100kHz~10MHz Resonant WPT Frequency Range and Analysis of EMF Guideline (공진형 무선전력전송 대역의 100kHz~10MHz 자기장에 의한 인체유도전류계산과 전자기장 인체보호기준 분석)

  • Shin, Hansu;Song, Hye-Jin;Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.110-119
    • /
    • 2013
  • As the technologies such as middle-range resonant WPT (wireless power transfer) advance that utilizes medium and low-frequency magnetic field, the importance of safety of such magnetic field is growing. The research on the effect of electromagnetic field on the human body has been mainly done on the GHz range of mobile phones, or 50~60Hz range of electric power systems. However, there has been relatively few works on the 100kHz~10MHz range used in the resonant wireless power transfer. Since there is a difference in the limiting value of magnetic field between widely used ICNIRP EMF guideline and IEEE C95.1 standard, there can be possible confusion when establishing EMF (Electromagnetic Field) standard on the wireless power transfer device in the future. In this paper, the induced current in the human body, which is the basic restriction of the EMF guideline, is calculated using Quasi-static FDTD method when 3D high-resolution human model is exposed to the 100kHz~10MHz magnetic field. Using this result, the feasibility of the magnetic field reference level in the ICNIRP guideline is analyzed.

Test and Evaluation of the Propeller Developed for a Multi-copter with the Take-off Weight of 25 kg (이륙 중량 25 kg급 멀티콥터용 프로펠러 시험 평가)

  • Kang, Hee Jung;Kim, Taejoo;Wee, Seong-Yong
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.4
    • /
    • pp.26-34
    • /
    • 2018
  • Structural static test and the performance test were conducted to determine whether the propeller developed for a multi-copter with the take-off weight of 25 kg satisfies the design requirement. The result of the structural test revealed that the propeller had a safety margin of 3 or more as the ultimate load and requirement load did not cause the specimen breakage. In the performance test, the propeller generated the hover thrust and maximum thrust of design requirement, and hover efficiency in the operating thrust range was greater than 0.73. Maximum hover efficiency increased by more than 3% compared to the reference propeller and electric power consumption decreased by more than 4% in the operating range. The propeller was found to be successfully developed based on the satisfaction rate of the structural strength requirement and the performance requirement.

Intelligent Phase Plane Switching Control of Pneumatic Artificial Muscle Manipulators with Magneto-Rheological Brake

  • Thanh, Tu Diep Cong;Ahn, Kyoung-Kwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1983-1989
    • /
    • 2005
  • Industrial robots are powerful, extremely accurate multi-jointed systems, but they are heavy and highly rigid because of their mechanical structure and motorization. Therefore, sharing the robot working space with its environment is problematic. A novel pneumatic artificial muscle actuator (PAM actuator) has been regarded during the recent decades as an interesting alternative to hydraulic and electric actuators. Its main advantages are high strength and high power/weight ratio, low cost, compactness, ease of maintenance, cleanliness, readily available and cheap power source, inherent safety and mobility assistance to humans performing tasks. The PAM is undoubtedly the most promising artificial muscle for the actuation of new types of industrial robots such as Rubber Actuator and PAM manipulators. However, some limitations still exist, such as the air compressibility and the lack of damping ability of the actuator bring the dynamic delay of the pressure response and cause the oscillatory motion. In addition, the nonlinearities in the PAM manipulator still limit the controllability. Therefore, it is not easy to realize motion with high accuracy and high speed and with respect to various external inertia loads in order to realize a human-friendly therapy robot To overcome these problems a novel controller, which harmonizes a phase plane switching control method with conventional PID controller and the adaptabilities of neural network, is newly proposed. In order to realize satisfactory control performance a variable damper - Magneto-Rheological Brake (MRB) is equipped to the joint of the manipulator. Superb mixture of conventional PID controller and a phase plane switching control using neural network brings us a novel controller. This proposed controller is appropriate for a kind of plants with nonlinearity uncertainties and disturbances. The experiments were carried out in practical PAM manipulator and the effectiveness of the proposed control algorithm was demonstrated through experiments, which had proved that the stability of the manipulator can be improved greatly in a high gain control by using MRB with phase plane switching control using neural network and without regard for the changes of external inertia loads.

  • PDF

The length of hospital stay of the industrial workers with back injury (산업재해 요통근로자의 재원기간에 관한 연구)

  • Lee, Bok-im
    • Korean Journal of Occupational Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.18-29
    • /
    • 2000
  • Back injury is frequent in industry workers and is a common cause of productivity loss. It has been reported that the insured of industrial accident insurance tend to stay in hospital longer than that of other types of insurance. The purpose of this study was to identify factors affecting the length of hospital stay for the treatment of back injury in the workers under industrial accident insurance. The results of this study help insurers develop reasonable industrial accident insurance policy for back injury claims and prevention strategies of work-related back injury. A total of 2,949 patients whose industrial accident insurance claim has been approved for the treatment of work-related back injury from January to December 1999 were included in this study. Relationship between the length of hospital stay and characteristics of patient, work place, back injury, and hospital were assessed using ANOVA, t-test, simple linear regression and multiple resgression. The major findings of this study are as follows : 1. The average length of hospital stay(LOS) was 91.82 days, respectively. 2. Characteristics of Patient LOS of male patients was longer than that of female patients, there was positive correlation between age and LOS and between average wage and LOS. Working period was negatively correlated with LOS. Distance from resident to hospital was positively correlated with LOS and LOS was significantly different dependign on type of duty. 3. Characteristics of Work Place LOS was significantly different depending on types of industry and geographical region of work place. Size of work place was positively correlated with LOS. 4. Characteristics of Back Injury Occupational back pain required shorter LOS compared with back injury due to electric shock. Number of concomitant illnesses and severity of disability were positively correlated with LOS. 5. Characteristics of Hospital Patients treated in community hospitals required significantly longer LOS. Treatment in hospitals with rehabilitation program required decreased LOS. This was more prominent as number of physicians specialized in rehabilitation. 6. Multiple regression analysis revealed that distance form resident to hospital, geographical region of work place, size of work place, number of concomitant illnesses, severity of disability, and type of hospital were factors affecting LOS.

  • PDF

Development of CW Doppler Sensor Signal Processing Board for Motion Detection (움직임 감지를 위한 CW도플러 센서 신호처리 보드 개발)

  • Han, Byung-hun;Oh, Chang-heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.866-869
    • /
    • 2015
  • In this paper, we propose a device for detect front object using low-price the CW Doppler sensor to prevent safety accident such as a bicycle, an electric wheelchair users. For this propose, we develop a signal process board and the object motion detect algorithm using to analyzing output signal of the CW Doppler sensor. Output signal from CW Doppler sensor is analog I and analog Q. The CW Doppler sensor shows phase I and phase Q of object differently when the object approach, stop, drop by sensor. We develop an algorithm that can detect object by discrimination information of phase using the CW Doppler sensor. The verification use firmware of applied hardware and algorithm. Then, the motion information can be confirming output depending on motion object by experiment normally. As a result, we check that the sensing information output by following motion of object and confirm an algorithm and motion of signal processing board.

  • PDF

The Behavior of Bearing Capacity for the Precast files (기성말뚝의 지지거동)

  • 박영호
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.107-116
    • /
    • 2000
  • Dynamic and static load tests are conducted in four construction sites by using steel pipe piles(SPP) and concrete piles to compare differences of load bearing mechanism. Steel pipe piles are instrumented with electric strain gages and are subject to dynamic load tests during driving. The damage of strain gages attached is checked simultaneously. Static load test is also conducted on the same piles after two to seven days' elapse. Then load-settlement behavior and shaft and/or tip resistances are measured. As a result, the allowable bearing capacity calculated by the Davisson's offset method of CAPWAP analysis shows 2~33% larger than that of static load test. The average value of allowable bearing capacity of static load test is closer to the allowable capacity obtained at the safety factor of 2.5 applied on ultimate bearing capacity than to the one obtained from the Davisson's offset method. The analysis of strain gage readings shows that unit skin friction increases with depth. Furthermore, the friction mobilized around the 1~2m above the pile tip considerably contributes to the total shaft resistance.

  • PDF