• 제목/요약/키워드: Electric pulsed power

검색결과 62건 처리시간 0.027초

유전체 장벽 방전을 위한 양방향 펄스 전원장치 (Bidirectional Pulse Power Supply for Dielectric Barrier Discharge)

  • 신완호;홍원석;정환명;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1521-1523
    • /
    • 2005
  • High voltage plasma power supply was adopted to control polluted gases and an ozone generation. Bidirectional pulse power supply consisted of power semiconductor switch devices, a high voltage transformer, and a control board adapted switching method. Plasma power supply with sinusoidal bidirectional pulse, which has output voltage range of 0-20kV and output frequency range of 1kHz-20kHz, is realized. Using proposed system, pulsed high voltage/high frequency discharges were tested in a DBD(dielectric barrier discharge) reactor, and the spatial distribution of a glow discharge was observed. The system showed stable operational characteristics, even though the voltage and the frequency increased. Above features were verified by experiments.

  • PDF

300kJ${\times}$B 모듈로 구성된 커패시터 뱅크의 특성 분석 (Characteristics of Capacitor Bank Composed of Eight Paralleled Modules)

  • 성기열;정재원;최영호;김진성;추증호;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1600-1602
    • /
    • 2001
  • A pulsed power supply of 2.4MJ capacitor bank has been developed to make investigation into electric gun technology. It is made up of eight paralleled 300kJ modules, and can supply various shape of high current pulse by changing charging voltage, inductance, capacitance, and firing time of each module. The 300kJ module has been designed and fabricated for the maximum operating voltage of 22kV, peak current of 150kA, and pulse duration of 1msec. The experiments of the modules were done, and the equivalent circuit of the module was determined. The characteristics of the module were analyzed more deeply through the circuit simulation. The experiments of the paralleled modules with inductance of 20 $\mu$H and load resistance of 100 m$\Omega$ were performed, where the modules were discharged simultaneously and/or sequentially. The results of the experiments were analyzed. The 2.4MJ capacitor bank is currently used as the pulsed power supply for the ETCG (Electro Thermal Chemical Gun) research.

  • PDF

액중 전기폭발법을 이용한 아연 나노분말 제조 및 분석 (Synthesis and Analysis of Zn Nanopowders by Wire Explosion In Liquids)

  • 조주현;김두헌;최시영;강충일;문갑영
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.824-829
    • /
    • 2012
  • Zn wires have been electrically exploded in methanol or distilled water using the pulsed power technologies. The nanopowders produced by the explosions have been observed by using SEM and TEM, and analyzed its phase by using EDS and XRD. The nanopowders produced in distilled water showed ZnO phase only. On the other hands, the nanopowder produced in methanol showed mixed phases with Zn and ZnO. The HR-TEM images of the nanopowders produced in methanol showed that the some particles have been coated with carbon like materials. It is considered that the carbon coatings could be depended on the positions of the particles during the plasma state formed by explosion.

Inactivation of Enterobacter sakazakii Inoculated on Formulated Infant Foods by Intense Pulsed Light Treatment

  • Choi, Mun-Sil;Cheigh, Chan-Ick;Jeong, Eun-Ae;Shin, Jung-Kue;Park, Ji-Yong;Song, Kyung-Bin;Park, Jong-Hyun;Kwon, Ki-Sung;Chung, Myong-Soo
    • Food Science and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1537-1540
    • /
    • 2009
  • Enterobacter sakazakii is a representative microorganism whose presence in infant foods can cause serious disease. The purposes of this study were to determine the inactivation effects of intense pulsed light (IPL) on E. sakazakii and the commercial feasibility of this sterilization method. The inactivation of E. sakazakii increased with increasing electric power and treatment time. The cells were reduced by 5 log cycles for 4.6 and 1.8 msec of treatment at 10 and 15 kV of electric field strength, respectively. The sterilization effects on commercial infant foods were investigated at 15 kV. The cell population in an infant beverage, an infant meal, and an infant powdered milk product inoculated with E. sakazakii were inactivated exponentially as a function of time and reduced by 4.0, 2.5, and 1.5 log cycles for 9.4, 7.0, and 7.0 msec of treatment time, respectively.

국제 열핵융합실험로 펄스전원계통의 무효전력보상기 검증 (Reactive Power Compensator for Pulsed Power Electric Network of International Thermonuclear Experimental Reactor)

  • 조현식;배상훈;오종석;차한주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.72-73
    • /
    • 2014
  • 본 논문에서는 ITER 펄스전원계통의 무효전력보상기(Reactive Power Compensator)의 해석 및 검증에 대하여 기술하였다. ITER 펄스전원계통은 66kV에 흐르는 무효전력량을 250MVar이하로 제한하기 위하여 정지형 무효전력보상기(Static Var Compensator)의 대표적인 장치인 싸이리스터 제어 리액터(TCR)와 고조파 필터(HF)로 구성된 무효전력보상기(RPC)를 사용한다. RPC에 적용되어 여러 ITER 초전도 코일 전원장치에서 발생하는 무효전력의 크기를 예측하여 보상하는 무효전력 보상기법을 해석한다. 본 논문에서는 RPC의 무효전력 보상동작을 실제 제어기와 RTDS를 연동하여 실험하여 검증하였고, RPC의 유무에 따라서 66kV 계통의 무효전력 최대값이 120MVar에서 40MVar로 감소하는 것을 확인하였다.

  • PDF

비대칭 펄스 DC 반응성 스퍼터링 법에 의한 CNx 박막의 기계적 특성에 관한 연구 (A Study on the Mechanical Properties of CNx Thin Films Deposited by Asymmetric Bipolar Pulsed D.C. Sputtering)

  • 김준호;김대욱;차병철;김선광;이병석;전신희;김대일;유용주
    • 열처리공학회지
    • /
    • 제22권5호
    • /
    • pp.290-297
    • /
    • 2009
  • In case of using Asymmetric Bipolar Pulsed DC (ABPD) power generator, thin film is efficiently deposited as ions are getting higher energy by suppressing target poisoning and electric arc. In this article, the mechanical properties of CNx thin films deposited on the STS 316L were compared with DC and ABPD power generators. The CNx thin films deposited with ABPD clearly improved wear resistance by higher ratio of sp3CN as compared with DC. Nb interlayer affected to increase the value of 10N of adhesion between CNx thin films and substrate. But, CNx thin films deposited with ABPD couldn't endure to wear load and decreased wear resistance as the films were too thinner than substrate. Nevertheless the higher substrate bias energy applied to perform the dense films, it wasn't shown benefits about the wear properties from DC sputtering. But, in case of using ABPD sputtering, the wear resistance was largely improved without changing morphology despite of thin films.

펄스전원을 이용한 오존발생특성 (Ozone Generation Characteristics with Pulse Power Supply)

  • 조국희;김영배;이홍식;김학규;이종민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1837-1839
    • /
    • 2003
  • Recently deep interests have been paid on the effective generation of ozone, which has been widely used for water treatment, deoderization, color removal and chemical processing of exhausted smoke. The silent discharge reaction has been proposed as the most effective in the many ozone generation methods by electric discharge, because silent discharge excel others in the condition of high ozone generation yield and low power consumption. In this paper, ozone water generated system measure with silent discharge characteristics and pulsed power supply.

  • PDF

펄스방전 확공형 앵커의 하중전이에 관한 연구 (Load Transfer on Pulsed Power Discharge Anchors)

  • 김성규;김낙경;김재원;주용선;김선주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.832-839
    • /
    • 2010
  • The pulse discharge anchor is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which is also known as pulse discharge and electric-spark technologies. The pulse discharge anchor has bulbed bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea and attached strain gauge at 10 anchors. The numerical predictions by Beam-Column analysis were compared with observed measurements in a field load test.

  • PDF

Analysis on Application of Flywheel Energy Storage System for offshore plants with Dynamic Positioning System

  • Jeong, Hyun-Woo;Kim, Yoon-Sik;Kim, Chul-Ho;Choi, Sung-Hwan;Yoon, Kyoung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권7호
    • /
    • pp.935-941
    • /
    • 2012
  • This paper describes a study of conventional electrical rig and simulated application of Flywheel Energy Storage system on the power system of the offshore plants with dynamic positioning system with the following aims: improve fuel consumption on engines, prevent blackout and mitigate voltage sags due to pulsed load and fault. Fuel consumption has been analyzed for the generators of the typical drilling rigs compared with the power plant with Flywheel Storage Unit which has an important aid in avoiding power interruption during DP (Dynamic Positioning) operation. The FES (Fly wheel Energy storage System) releases energy very quickly and efficiently to ensure continuity of the power supply to essential consumers such as auxiliary machinery and thrusters upon main power failure. It will run until the standby diesel generator can start and supply the electric power to the facilities to keep the vessel in correct position under DP operation. The proposed backup method to utilize the quick and large energy storage Flywheel system can be optimized in any power system design on offshore plant.

Influence of Endurance tests on Space Charge Distribution of 160kV HVDC XLPE Cable

  • Liu, Yun-Peng;Liu, He-Chen
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.302-309
    • /
    • 2017
  • The ageing of XLPE cable insulation will lead to the accelerating accumulation of space charge, which will greatly affect the safe operation of the HVDC cable. In order to investigate the influence of different ageing modes on the space charge distribution of the HVDC cable, thermal stressed, electrical stressed and electro-thermal stressed endurance tests were carried out on the XLPE peelings. The tested XLPE peelings were obtained from 160kV HVDC cable insulation. The endurance tests were carried at thermal stress of 363K, electrical stress of 20kV/mm DC and a combination of both. The Pulsed Electro-Acoustic (PEA) method was used to measure the space charge distribution of the samples. The influences of ageing on the trap energy distribution were analyzed based on the isothermal relaxation theory and the decay characteristics of the space charge. The results showed that thermal ageing would help to improve the crystalline morphologies of the XLPE at the early stage. The total amount of space charge decreased compared to the ones before thermal ageing. The long term of electrical stress would result in the cleavage of polymer molecule chains which would intensify the accumulation of space charge and increase the density and depth of electron traps. With a combination of electrical and thermal stress, the injection and migration of space charge were more significant. Besides, the depth and density of electron traps increased rapidly with the increase of endurance time.